0x0EE00000
BSE RAID fault

Explanation

A RAID fault has occurred in the BladeCenter Storage Expansion Unit in the specified blade server.

Severity

Error

Alert Category

Blades (Critical) - mmTrapBladeC

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Alarm Panel LED (BC T and BC HT)

Critical

User response

Perform these steps:
  1. Update the ServeRAID-related code (including driver, BIOS and service processor firmware, and the ServeRAID application) for the blade server.
  2. Update the hard drive firmware.
  3. Reseat the ServeRAID SAS controller in the BladeCenter Storage Expansion Unit.
  4. Replace the following components one at a time, in the order shown, restarting the blade server each time:
    1. ServeRAID SAS controller.
    2. BladeCenter Storage Expansion Unit.

Refer to the Problem Determination and Service Guide for the specified blade server type for information about the BladeCenter Storage Expansion Unit. The Problem Determination and Service Guide is available on the Web.