Explanation
A RAID fault has occurred in the BladeCenter Storage Expansion Unit in the specified blade server.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
No
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Update the ServeRAID-related code (including driver, BIOS and service processor firmware, and the ServeRAID
application) for the blade server.
- Update the hard drive firmware.
- Reseat the ServeRAID SAS controller in the BladeCenter Storage Expansion Unit.
- Replace the following components one at a time, in the order shown, restarting the blade server each time:
- ServeRAID SAS controller.
- BladeCenter Storage Expansion Unit.
Refer to the Problem Determination and Service Guide for the specified blade server type
for information about the BladeCenter Storage Expansion Unit. The Problem Determination and Service Guide is available on the Web.