0x1E00E005
Open Fabric Manager configuration mismatch detected between expected configuration and the actual configuration for blade 05. Expected configuration will take affect when blade restarted.

Explanation

The Open Fabric Manager configuration detected by the advanced management module does not match the action Open Fabric Manager configuration for the specified blade server. The active configuration from the specified blade server will be used.

Severity

Warning

Alert Category

Blades (Warning) - mmTrapBladeN

Log Source

Blade_##

Automatically notify service

No

Recoverable

No

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Power off the specified blade server.
  2. Attempt to apply the Open Fabric Manager configuration again.

See the BladeCenter Open Fabric Manager Installation and User's Guide for more information. The guide is available on the Web.