0x4001711E
Standby MM failed to synchronize with primary MM. Standby network interface is disabled.

Explanation

The standby advanced management module failed to synchronize with the primary advanced management module. Therefore, the network interface for the standby advanced management module is disabled. This log entry can be seen only after a failover has occurred and the standby advanced management module becomes the primary.

Severity

Warning

Alert Category

N/A - mmTrapRemoteLoginS

Log Source

SERVPROC

Automatically notify service

No

Recoverable

No

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. If the firmware configuration has not changed recently, reseat the standby advanced management module. Otherwise, reseat the primary advanced management module.
  2. Check the IBM Support Web page for any service bulletins that might be related to this problem.
  3. Restore system defaults to factory settings. Then attempt to apply the configuration again.