Explanation
The specified user requested that the partition be removed for the specified scalable blade complex.
As a result, all blade servers in the scalable blade complex will operate independently until a
new partition has been created.
Severity
Informational
Alert Category
Blades (Informational)
-
mmTrapBladeS
Log Source
Audit
Automatically notify service
No
Recoverable
No
Example Message
Complex A01C (blades 4,5,6,7): Delete Partition 1 by USERID at 10.10.10.50 (Web)
User response
If the blade servers in the scalable blade complex are not operating independently, perform these steps:
- Ensure that all the blade servers in the scalable blade complex are powered off.
- Check the event log for other events related to the specified blade servers and resolve those events.
- Reset the blade system management processor on all blade servers in the scalable blade complex. You
can reset the service processor through the advanced management module Web interface from the
Blade Power/Restart page.
- Reseat the scalable blade complex.
- Update the firmware for the service processor on the blade server. You can
find the appropriate firmware on the IBM BladeCenter software and device drivers Web page.