0x4300010E
Complex Descriptor is corrupted. Partition configuration and control not available.

Explanation

The blade server provided a complex descriptor that is not valid. The advanced management module cannot perform partition configuration or control until a valid complex descriptor is provided by the target scalable blade complex.

Severity

Warning

Alert Category

Blades (Informational) - mmTrapBladeS

Log Source

Blade_##

Automatically notify service

No

Recoverable

No

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Reset the blade system management processor on all blade servers in the scalable blade complex. You can reset the service processor through the advanced management module Web interface from the Blade Power/Restart page.
  2. Reseat the scalable blade complex.
  3. Update the firmware for the service processor on the specified blade server. You can find the appropriate firmware on the IBM BladeCenter software and device drivers Web page.