Complex Descriptor is corrupted. Partition configuration and control not available.
Explanation
The blade server provided a complex descriptor that is not valid. The
advanced management module cannot perform partition configuration or control until a valid
complex descriptor is provided by the target scalable blade complex.
Severity
Warning
Alert Category
Blades (Informational)
-
mmTrapBladeS
Log Source
Blade_##
Automatically notify service
No
Recoverable
No
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- Reset the blade system management processor on all blade servers in the scalable blade complex. You
can reset the service processor through the advanced management module Web interface from the
Blade Power/Restart page.
- Reseat the scalable blade complex.
- Update the firmware for the service processor on the specified blade server. You can
find the appropriate firmware on the IBM BladeCenter software and device drivers Web page.