I/O and Graphics Adapter problem detected.
Explanation
A problem with the I/O and Graphics Adapter has been detected for the specified blade.
Severity
Warning
Alert Category
Blades (Warning)
-
mmTrapBladeN
Log Source
Blade_##
Automatically notify service
No
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- If this is occurring on an HC10, reseat the graphics adapter and video controller.
- If this is occurring on any other blade server, reseat the blade server.
- Update the firmware for the video adapter.
- Update BIOS for the blade server.
- Replace the compression card.
- Generate a call home using Service Advisor:
- If this is occurring on an HC10 blade workstation, replace the graphics adapter. Be ready to provide part number
for the adapter.
- If this is occurring on any other blade server, replace the system board.