0x6E000001
I/O and Graphics Adapter problem detected.

Explanation

A problem with the I/O and Graphics Adapter has been detected for the specified blade.

Severity

Warning

Alert Category

Blades (Warning) - mmTrapBladeN

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. If this is occurring on an HC10, reseat the graphics adapter and video controller.
  2. If this is occurring on any other blade server, reseat the blade server.
  3. Update the firmware for the video adapter.
  4. Update BIOS for the blade server.
  5. Replace the compression card.
  6. Generate a call home using Service Advisor:
    • If this is occurring on an HC10 blade workstation, replace the graphics adapter. Be ready to provide part number for the adapter.
    • If this is occurring on any other blade server, replace the system board.