Unable to read VPD for Storage Module 02.
Explanation
The advanced management module is unable to read the vital product data (VPD) for the specified storage module.
Severity
Warning
Alert Category
Storage Modules (Warning)
-
mmTrapStorageN
Log Source
Stor_##
Automatically notify service
No
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- Verify that the storage module LED is not lit. If it is not lit, continue monitoring the event log for additional messages. At your earliest convenience, reseat the storage module.
- If the storage module LED is lit, reseat the storage module. Before reseating the storage module, make sure that the blade servers are not actively working with the hard disk drives (the hard disk drive LEDs are lit when drive activity is occurring).
- If the problem persists, check the IBM Support Web page for any service bulletins that might be related to this problem.