under non-recoverable threshold.
Explanation
The service processor on the specified blade server has detected that the specified component has reached or is below the specified nonrecoverable critical threshold (such as under voltage).
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
No
Recoverable
Yes
Example Message
System board (5V Sense) voltage under nonrecoverable threshold. Reading: 6.10, Threshold: 7.00
Alarm Panel LED (BC T and BC HT)
Critical
User response
Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The
Problem Determination and Service Guide is available on the Web.
If you do not have access to the Problem Determination and Service Guide, perform these steps:
- If the under voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events.