0x806F010F
hang

Explanation

The specified blade server has hung while loading BIOS.

Severity

Error

Alert Category

Blades (Critical) - mmTrapBladeC

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Example Message

FW/BIOS, firmware progress (Pri FW Corrupt) hang

Alarm Panel LED (BC T and BC HT)

Critical

User response

Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The Problem Determination and Service Guide is available on the Web.

If you do not have access to the Problem Determination and Service Guide, perform these steps:
  1. Attempt to reboot the blade server.
  2. Determine the type of blade server for which this error has occurred. You can find the blade server type from the advanced management module Hardware VPD information:
    1. From the advanced management module Web Interface, click Hardware VPD.
    2. From the command-line interface, enter the Info command).