0x806F0113
bus timeout

Explanation

The service processor on the specified blade server has detected a bus timeout.

Severity

Error

Alert Category

Blades (Critical) - mmTrapBladeC

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Example Message

Chassis (NMI State) bus timeout

Alarm Panel LED (BC T and BC HT)

Critical

User response

Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The Problem Determination and Service Guide is available on the Web.

If you do not have access to the Problem Determination and Service Guide, perform these steps:
  1. Remove the blade server from the BladeCenter chassis; then, reinstall it.
  2. Reseat all the options installed in the blade server one, restarting the blade server each time, at a time to determine where the problem is located.
  3. Remove options from the blade server one at a time to determine where the problem is located.
  4. Replace the following components one at a time, in the order shown, restarting the blade server each time:
    1. All options installed in the blade server.
    2. System board assembly (trained service technician only).