0x806F0509
power unit did not respond to power on request

Explanation

The service processor on the specified blade server has detected a soft power control failure (the blade server did not respond to a power no request).

Severity

Error

Alert Category

Blades (Critical) - mmTrapBladeC

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Example Message

System board (Sys pwr monitor) power unit did not respond to power on request

Alarm Panel LED (BC T and BC HT)

Critical

User response

Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The Problem Determination and Service Guide is available on the Web.

If you do not have access to the Problem Determination and Service Guide, perform these steps:
  1. From the advanced management module, use the Power Management page to ensure that there is sufficient power budget to enable this blade server to power on.
  2. Check the IBM Support Web page for any service bulletins that might be related to this problem.