Explanation
The service processor on the specified blade server detected a problem with one of the hard disk drives in a RAID array, placing the array in a critical state.
The loss of another hard disk drive in the array could cause the array to fail.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
No
Recoverable
Yes
Example Message
Hard drive 1 (Drive 1 Status) in critical array
Alarm Panel LED (BC T and BC HT)
Critical
User response
Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The
Problem Determination and Service Guide is available on the Web.