0x806F0513
PCI system error

Explanation

The service processor on the specified blade server has detected a PCI system error for the specified component. The blade server will reboot.

Severity

Error

Alert Category

Blades (Critical) - mmTrapBladeC

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Example Message

Alarm Panel LED (BC T and BC HT)

Critical

User response

Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The Problem Determination and Service Guide is available on the Web.

If you do not have access to the Problem Determination and Service Guide, perform these steps:
  1. If you have a PCI adapter in your blade server:
    1. Verify that the PCI adapter is supported in the blade server (go to the IBM ServerProven Web site).
    2. Reseat the PCI adapter.
  2. Refer to the Problem Determination and Service Guide for the specified blade server for information related to PCI adapters. You can find the Problem Determination and Service Guide on the Web.
  3. Check the IBM Support Web page for any service bulletins that might be related to this problem.