Explanation
The service processor on the specified blade server has detected a problem with one or more hard disk drives in
a RAID array, resulting in a failure of the RAID array.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
Yes
Recoverable
Yes
Example Message
Hard drive 1 (Drive 1 Status) in failed array
Alarm Panel LED (BC T and BC HT)
Critical
User response
Refer to the Problem Determination and Service Guide for the specified blade server to determine the device-specific actions to resolve this event. The
Problem Determination and Service Guide is available on the Web.
If you do not have access to the Problem Determination and Service Guide, perform these steps:
- If the RAID array is external to the blade, verify that the array has power.
- Go to the interface for your RAID management implementation and resolve any problems that are found.
If hard disk drives are bad, note the part number and size of the hard disk drives for replacement.