To ship a BladeCenter S chassis in an Office Enablement Kit, you
will need to install the two upper shipping brackets and M5 screws
(provided in the BladeCenter S chassis rack installation kit) and
the lower shipping bracket (provided with the Office Enablement Kit).
M5 screws are used to secure the lower shipping bracket
to the BladeCenter S chassis and are provided with the BladeCenter
S chassis rack installation kit. M6 screws are used to secure the
shipping brackets to the rack cabinet and are provided with the BladeCenter
S chassis rack installation kit as well as the Office Enablement Kit.
-
Install the cage nuts for the upper left, upper right,
and lower shipping brackets (if you did not install them when initially
installing the BladeCenter S chassis in the Office Enablement Kit).
-
Remove the bezel for the BladeCenter S chassis.
-
Remove the screws that secure the front of the BladeCenter
S chassis to the rails.
-
From the rear of the BladeCenter S chassis, carefully
push the chassis forward to provide enough clearance to install the
cage nuts.
Important: When pushing the BladeCenter
S chassis, grasp the top and bottom of the chassis. Pushing on the
components within a chassis could damage the components.
-
Install the cage nuts for the upper left, upper right,
and lower shipping brackets.
-
From the front of the BladeCenter S chassis, carefully
push the chassis back into the Office Enablement Kit.
Important: When pushing the BladeCenter S chassis,
grasp the top and bottom of the chassis. Pushing on the components
within a chassis could damage the components.
-
Install the upper right shipping bracket (as you are facing
the rear of the BladeCenter S chassis.
-
Align the shipping bracket so that the bottom of the
shipping bracket will fit into the slot to the right of power module
bay 1.
-
Align the holes in the shipping bracket with the cage
nuts in the rack cabinet.
-
Insert the shipping bracket into the chassis slot.
-
Secure the shipping bracket to the rack cabinet with
the M6 screws that are provided.
-
Repeat these steps to install the upper left shipping bracket.
-
Install the lower shipping bracket.
-
Position the lower shipping bracket so that it is flush
with the bottom of the BladeCenter S chassis.
-
Slide the lower shipping bracket beneath the BladeCenter
S chassis until the raised holes in the lower shipping bracket are
flush with the rear of the BladeCenter S chassis. The holes in the
lower shipping bracket should align with the cage nuts in the rack
cabinet rails.
-
Secure the lower shipping bracket to the rack cabinet
rails using the M6 screws that are provided.
-
Secure the lower shipping bracket to the BladeCenter
S chassis by installing the M5 screws in the raised holes of the lower
shipping bracket.
-
Insert four M6 screws in the front of the BladeCenter S
chassis to secure it to the rack cabinet.
-
Install the bezel on the BladeCenter S chassis.