The power-control button does not work. |
- Reseat the control-panel connector - See Blade server controls and LEDs.
- Replace the bezel assembly - See Removing the bezel assembly and Installing the bezel assembly.
- (Trained service technician only) Replace the system-board assembly -
See Removing the system-board assembly and Installing the system-board assembly.
|
The blade server does not turn on. |
- Check the function of the shared BladeCenter unit resources. See Solving shared BladeCenter resource problems.
- Make sure that the power-on LED on the blade server control panel is flashing
slowly. See Blade server controls and LEDs.
- Check the power-management policies in the operating system for the blade
server. See the Management Module User's Guide for more information.
- Check the management-module log of the corresponding blade server for
an error that is preventing the blade server from turning on. See Error logs.
- Reseat the blade server - See Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit.
- If you just installed a device in the blade server, remove it and restart
the blade server. If the blade server now starts, you might have installed
more devices than the power to that blade server bay supports.
- If you tried another blade server in the blade server
bay when you check the function of the shared BladeCenter unit resources and
the other blade server worked, complete the following tasks on the blade server
that you removed:
- If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit.
- Replace the following components one at a time, in the order shown, restarting
the blade server each time:
- Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit.
- (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly.
- See Solving undetermined problems.
|
The blade server turns off for no apparent reason. |
- Check the function of the shared BladeCenter unit resources. See Solving shared BladeCenter resource problems.
- (Trained service technician only) If the microprocessor error LED is lit,
replace the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink.
- (Trained service technician only) Replace the system-board assembly -
See Removing the system-board assembly and Installing the system-board assembly.
|
The blade server does not turn off. |
- Verify whether you are using an Advanced Configuration and Power Interface
(ACPI) or non-ACPI operating system.
- If you are using a non-ACPI operating system, complete the following steps:
- Turn off the blade server by pressing the power-control button for 4 seconds.
See Blade server controls and LEDs.
- If the blade server fails during POST and the power-control button does
not work, remove the blade server from the bay and reseat it. See Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit.
- If the problem remains or if you are using an ACPI-aware operating system,
complete the following steps:
- Check the power-management policies in the operating system for the blade
server.
- (Trained service technician only) Replace the system-board assembly -
See Removing the system-board assembly and Installing the system-board assembly.
|