Use this information to diagnose and resolve removable-media drive problems in the blade server.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. The removable-media (CD, DVD, or diskette) drives are shared BladeCenter unit resources. First, make sure that the drives are assigned to the blade server; then, see the following table and Solving shared BladeCenter resource problems.
|
|
---|---|
Symptom | Action |
All removable-media drive problems. |
|
The CD or DVD drive is detected as /dev/sr0 by SUSE Linux. (If the SUSE Linux operating system is installed remotely on a blade server that is not the current owner of the media tray [CD or DVD drive, diskette drive, and USB port], SUSE Linux detects the CD or DVD drive as /dev/sr0 instead of /dev/cdrom.) | Establish a link between /dev/sr0 and /dev/cdrom as follows:
|
The CD or DVD drive is not recognized after being switched back to the blade server running Windows 2000 Advanced Server with SP3 applied. (When the CD or DVD drive that is owned by blade server x is switched to another blade server, then is switched back to blade server x, the operating system in blade server x no longer recognizes the CD or DVD drive. This happens when you have not safely stopped the drives before you switched ownership of the media tray [CD or DVD drive, diskette drive, and USB port]). |
Note: Because the BladeCenter unit uses USB to communicate
with the media tray devices, switching ownership of the media tray to another
blade server is the same as disconnecting a USB device. Before you switch
ownership of the CD or DVD drive (media tray) to another blade server, safely
stop the media tray devices on the blade server that currently owns the media
tray, as follows:
You can now safely switch ownership of the media tray to another blade server. |