Microprocessor: Supports up to two multi-core IntelXeon microprocessors.

Note: Use the Setup utility to determine the type and speed of the microprocessors in the blade server.
Memory:
  • 12 dual inline memory module (DIMM) connectors
  • Type: Very Low Profile (VLP) double-data rate (DDR3) DRAM. Supports 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB DIMMs with up to 192 GB of total memory on the system board
Integrated functions:
  • Horizontal-compact-form-factor (CFFh) expansion card interface
  • Vertical-combination-I/O (CIOv) expansion card interface
  • Local service processor: Integrated Management Module (IMM) with Intelligent Platform Management Interface (IPMI) firmware
  • Integrated Matrox G200eV video controller
  • LSI 1064E SAS controller
  • Broadcom BCM5709S dual-port Gigabit Ethernet controller
  • Integrated keyboard/video/mouse (cKVM) controller through IMM
  • Light path diagnostics
  • RS-485 interface for communication with the management module
  • Automatic server restart (ASR)
  • USB 2.0 for communication with cKVM and removable media drives (an external USB port is not supported)
  • Serial over LAN (SOL)
  • Redundant buses for communication with keyboard, mouse, and removable media drives
Predictive Failure Analysis (PFA) alerts:
  • Microprocessors
  • Memory
  • Storage drives

Electrical input: 12 V dc

Environment:

  • Air temperature:
    • Blade server on: 10°C to 35°C (50°F to 95°F). Altitude: 0 m to 914.4 m (0 ft to 3000 ft)
    • Blade server on: 10°C to 32°C (50°F to 89.6°F). Altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
    • Blade server off: 10°C to 43°C (50°F to 109.4°F). Altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
    • Blade server shipping: -40°C to 60°C (-40°F to 140°F)
  • Humidity:
    • Blade server on: 8% to 80%
    • Blade server off: 8% to 80%
    • Blade server storage: 5% to 80%
    • Blade server shipment: 5% to 100%
  • Particulate contamination:
    Attention: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.

Drives: Supports up to two hot-swap, small form factor (SFF) Serial Attached SCSI (SAS) or Serial ATA (SATA) storage drives

Size (Type 7870 and Type 1936):
  • Height: 24.5 cm (9.7 inches) (6U)
  • Depth: 44.6 cm (17.6 inches)
  • Width: 2.9 cm (1.14 inches)
  • Maximum weight: 4.8 kg (10 lb)
Size (Type 1911):
  • Height: 24.5 cm (9.7 in)
  • Depth: 44.6 cm (17.6 in)
  • Width: 14.5 cm (5.71 in)
  • Maximum weight: 8.15 kg (40.02 lb)
NEBS Environment
  • Air temperature:
    • Blade server on: 5°C to 40°C (41°F to 104°F). Altitude: -60 m to 1800 m (-197 ft to 6000 ft)
    • Blade server on: 5°C to 30°C (41°F to 86°F). Altitude: 1800 m to 4000 m (6000 ft to 13000 ft)
    • Blade server off: -5°C to 55°C (23°F to 131°F). Altitude: -60 m to 1800 m (-197 ft to 6000 ft)
    • Blade server off: -5°C to 45°C (23°F to 113°F). Altitude: 1800 m to 4000 m (6000 ft to 13000 ft)
    • Blade server storage: -40°C to 60°C (-40°F to 140°F)
  • Humidity: 8% to 85%
  • Particulate contamination:
    Attention: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.