Index Description CRU part number (Tier 1) CRU part number (Tier 2) FRU part number
1 Cover (Type 7870) 46C7201    
1 Cover (Type 1911)   68Y7425  
2 Expansion card, Broadcom 10 Gb 2-port Ethernet CFFh (model CCx) 44W4469    
2 Expansion card, Broadcom 10 Gb Gen 2 2-port Ethernet CFFh (model CGx) 46M6169    
2 Expansion card, Broadcom 10 Gb 4-port Ethernet CFFh (model GCx) (option) 44W4472    
2 Expansion card, 2/4 port Ethernet CFFh (option) 44W4488    
2 Expansion card, 2-Port 10 Gb multi-function I/O adapter CFFh (model HAx) 49Y4239    
2 Expansion card, 2-Port 40 Gb Infiniband CFFh (option) 60Y0927    
2 Expansion card, 4X Infiniband DDR CFFh (option) 49Y9976    
2 Expansion card, Emulex 2-Port 40Gb Infiniband CFFh (option) 60Y0927    
2 Expansion card, Emulex 10 GbE Virtual Fabric Adapter Advanced II (model D4x, 91x) 90Y3569    
2 Expansion card, Emulex 10 GbE Virtual Fabric Adapter 2 for IBM BladeCenter (CFFh) 00Y3290    
2 Expansion card, Emulex 10 Gb Ethernet Virtual Fabric Adapter Advanced 2 for IBM BladeCenter (CFFh) 00Y3292    
2 Expansion card, Emulex Virtual Fabric Adapter for IBM BladeCenter (CFFh) 00Y3294    
2 Expansion card, Emulex Virtual Fabric Adapter Advanced for IBM BladeCenter (CFFh) 00Y3296    
2 Expansion card, QLogic 2-port 10 Gb CFFh (option) 00Y3283    
2 Expansion card, Qlogic Ethernet and 8 Gb Fibre Channel CFFh (option) 00Y5630    
3 Heat sink, microprocessor (all models)     46C3545
4 Microprocessor, Intel Xeon E5603 1.6 GHz/1066MHz-4MB 80W (quad core) (model A5x)     81Y5952
4 Microprocessor, Intel Xeon L5609 1.86 GHz/4.8GTps QPI/1066MHz-12MB 40W (quad core) (model CTO) (option)     69Y0783
4 Microprocessor, Intel Xeon E5502 1.86 GHz/4.8GTps QPI/800MHz-4MB 80W (dual core) (models D2x, EDx)     46D1272
4 Microprocessor, Intel Xeon L5618 1.87 GHz/5.86GTps QPI 12MB 40W (quad core) (option)     69Y4713
4 Microprocessor, Intel Xeon L5508 2.0 GHz/5.86GTps QPI/1066MHz-8MB 38W (dual core) (option)     59Y5571
4 Microprocessor, Intel Xeon L5638 2.0 GHz/5.86GTps QPI 12MB 60W (six core) (option)     69Y4715
4 Microprocessor, Intel Xeon E5503 2.0 GHz/4.8GTps QPI/800MHz-4MB 80W (dual core) (models D3x, EEx)     69Y0781
4 Microprocessor, Intel Xeon E5504 2.0 GHz/4.8GTps QPI/800MHz-4MB 80W (dual core) (models A2x, CCx)     46D1271
4 Microprocessor, Intel Xeon L5630 2.13 GHz/5.86GTps QPI/1066MHz-12MB 40W (quad core) (option)     59Y3691
4 Microprocessor, Intel Xeon L5506 2.13 GHz/4.8GTps QPI/800MHz-4MB 60W (quad core) (option)     46D1268
4 Microprocessor, Intel Xeon E5506 2.13 GHz/4.8GTps QPI/800MHz-4MB 80W (quad core) (option)     46D1270
4 Microprocessor, Intel Xeon L5518 2.13 GHz/5.86GTps QPI/1066MHz-8MB 60W (quad core) (models M2x, M3x)     49Y5174
4 Microprocessor, Intel Xeon E5606 2.13 GHz/1066MHz-8MB 80W (quad core) (option)     81Y5953
4 Microprocessor, Intel Xeon E5507 2.26 GHz/4.8GTps QPI/800MHz-4MB 80W (quad core) (model A4x)     69Y0782
4 Microprocessor, Intel Xeon L5520 2.26 GHz/5.86GTps QPI/1066MHz-8MB 60W (quad core) (models 2Mx, 6Mx, L2x)     46D1269
4 Microprocessor, Intel Xeon E5520 2.26 GHz/5.86GTps QPI/1066MHz-8MB 80W (quad core) (model L2x)     46D1267
4 Microprocessor, Intel Xeon L5640 2.26 GHz/5.86GTps QPI/1333MHz-12MB 60W (six core) (model N2x)     49Y7054
4 Microprocessor, Intel Xeon E5607 2.26 GHz/1066MHz-8MB 80W (quad core) (models A7x, E1Y)     81Y5954
4 Microprocessor, Intel Xeon L5530 2.40 GHz/5.86GTps QPI/1066MHz-8MB 60W (quad core) (model L3x)     49Y6807
4 Microprocessor, Intel Xeon E5530 2.40 GHz/5.86GTps QPI/1066MHz-8MB 80W (quad core) (models B3x, EBx)     46D1266
4 Microprocessor, Intel Xeon E5620 2.40 GHz/5.86GTps QPI/1066MHz-12MB 80W (quad core) (models G2x, G2X, K4x)     49Y7053
4 Microprocessor, Intel Xeon E5645 2.40 GHz/5.86GTps QPI 12MB 80W (six core) (models 91x, 92x)     69Y4714
4 Microprocessor, Intel Xeon E5540 2.53 GHz/5.86GTps QPI/1066MHz-8MB 80W (quad core) (model B4x)     46D1265
4 Microprocessor, Intel Xeon E5630 2.53 GHz/5.86GTps QPI/1066MHz-12MB 80W (quad core) (model EGx)     49Y7052
4 Microprocessor, Intel Xeon E5649 2.53 GHz/1333MHz-12MB 80W (six core) (models B6x, D4x, D5x, E2Y)     81Y5955
4 Microprocessor, Intel Xeon E5640 2.66 GHz/5.86GTps QPI/1066MHz-12MB 80W (quad core) (models G4x and GCx)     49Y7051
4 Microprocessor, Intel Xeon X5650 2.66 GHz/6.4GTps QPI/1333MHz-12MB 95W (six core) (models HAx, H2x)     49Y7040
4 Microprocessor, Intel Xeon X5550 2.67 GHz/6.4 GTps QPI/1333MHz-8MB 95W (quad core) (option)     46D1264
4 Microprocessor, Intel Xeon X5560 2.80 GHz/6.4 GTps QPI/1333MHz-8MB 95W (quad core) (models 1Mx, 5Mx, C3x, ECx)     46D1263
4 Microprocessor, Intel Xeon X5660 2.80 GHz/6.4 GTps QPI/1333MHz-12MB 95W (six core) (option)     49Y7039
4 Microprocessor, Intel Xeon X5570 2.93 GHz/6.4 GTps QPI/1333MHz-8MB 95W (quad core) (models 3Mx, C4x)     46D1262
4 Microprocessor, Intel Xeon X5670 2.93 GHz/6.4 GTps QPI/1333MHz-12MB 95W (six core) (model H4x)     49Y7038
4 Microprocessor, Intel Xeon X5647 2.93 GHz/1066MHz-12MB 130W (quad core) (model B5x)     81Y5956
4 Microprocessor, Intel Xeon X5667 3.06 GHz/6.4 GTps QPI/1333MHz-12MB 95W (quad core) (model H5x)     49Y7050
4 Microprocessor, Intel Xeon X5675 3.06 GHz/1333MHz-12MB 95W (six core) (models C6x, E3Y)     81Y5958
4 Microprocessor, Intel Xeon X5672 3.2 GHz/1333MHz-12MB (quad core) (model C5x)     81Y5957
4 Microprocessor, Intel Xeon X5680 3.33 GHz/6.4 GTps QPI/1333MHz-12MB 130W (six core) (model F2x)     69Y0849
4 Microprocessor, Intel Xeon X5677 3.46 GHz/6.4 GTps QPI/1333MHz-12MB 130W (quad core) (model F3x)     69Y0850
4 Microprocessor, Intel Xeon X5690 3.46 GHz/1333MHz-12MB 130W (six core) (model C8x)     81Y5960
4 Microprocessor, Intel Xeon X5687 3.6 GHz/1333MHz-12MB 130W (quad core) (model C7x)     81Y5959
5 Memory, DIMM filler (Type 7870 models 1Mx, 5Mx, 6Mx, A2x, A4x, A5x, A7x, B3x, B4x, B5x, B6x, C3x, C4x, C5x, C6x, C7x, C8x, CCx, D2x, D3x, D4x, D5x, E1Y, E2Y, E3Y, ECx, EBx, EDx, EEx, F2x, F3x, EGx, G2x, G4x, GCx, H2x, H4x, H5x, HAx, K4x, L2x, L3x, M2x, N2x, 91x, 92x) (Type 1911 model G2X) (Type 1936 model C4x) 60H2962    
6 Memory, 1 GB VLP DDR3 (models A2x, A4x, CCx, D2x, D3x) 44T1495    
6 Memory, 1 GB single rank VLP DDR3-1333 PC3-10600 (option) 49Y1437    
6 Memory, 2 GB VLP DDR3 2Rx8 VLP (models L3x, M2x) 44T1496    
6 Memory, 2 GB VLP DDR3-1333 (Type 7870 models B3x, B4x, C3x, C4x, ECx, EDx, EBx, ECx, L2x) (Type 1936 model C4x) 44T1497    
6 Memory, 2 GB single rank VLP DDR3-1333 (1.35V) (option) 46C0573    
6 Memory, 2 GB single rank VLP DDR3-1333 PC3-10600 (option) 49Y1439    
6 Memory, 2 GB dual rank VLP DDR3-1333 PC3-10600 (models EEx, EGx, F2x, F3x, G2x, G2X, G4x, GCx, H2x, H4x, H5x, HAx, N2x) 49Y1438    
6 Memory, 2 GB 1Rx8 2 Gb DDR3 RDIMM (option) 44T1584    
6 Memory, 2 GB 1Rx8 2 Gb ECC RDIMM (option) 46C0572    
6 Memory, 4 GB (1Gb, 2Rx4) VLP DDR3-1333 (1.35V) (option) 46C0579    
6 Memory, 4 GB dual rank VLP DDR3-1333 PC3-10600 (option) 49Y1440    
6 Memory, 4 GB dual rank VLP DDR3-1333 (2DPC@1333) (option) 46C0533    
6 Memory, 4 GB VLP DDR3 (Type 1936) (option) 46C0528    
6 Memory, 4 GB VLP DDR3-1333 (Type 7870 models 1Mx, 2Mx, 3Mx, 5Mx, 6Mx) 44T1498    
6 Memory, 4 GB VLP DDR3-1333 2Rx8 (model K4x) (option) 44T1586    
6 Memory, 4 GB 2 GBIT 1RX4) PC3L-10600R-999 VLP RDIMM (models A5x, A7x, B5x, B6x, C5x, C6x, C7x, C8x, D4x, D5x, E1Y, E2Y) 46C0575    
6 Memory, 4 GB 2Rx8 2 Gb ECC RDIMM (option) 46C0576    
6 Memory, 8 GB VLP DDR3 (Type 1936) (option) 46C0529    
6 Memory, 8 GB VLP DDR3-1066 (Type 7870) (option) 44T1580    
6 Memory, 8 GB (2 Gb, 2Rx4) VLP DDR3-1066 (1.35V) (option) 46C0581    
6 Memory, 8 GB dual rank VLP DDR3-1333 PC3-10600 (option) 49Y1441    
6 Memory, 8 GB 2Rx4 VLP DDR3-1333 PC3-10600 (1.35V) (models 91x, 92x) 46C0580    
6 Memory, 8 GB dual rank VLP DDR3-1333 (2DPC@1333) (option) 46C0534    
6

Memory, 8 GB (8 GB, 1Rx4) 1.35V PC3L-10600 CL9 ECC
DDR3 1333MHz VLP RDIMM (option)
(for use with Intel Xeon 5600 series microprocessors)

00D4983    
6

Memory, 8 GB (8 GB, 2Rx8) 1.35V PC3L-10600 CL9 ECC
DDR3 1333MHz VLP RDIMM (option)
(for use with Intel Xeon 5600 series microprocessors)

00D4987    
6

Memory, 16 GB (4 Gb, 2Rx4) 1.35V DDR3-1333 VLP RDIMM
(for use with Intel Xeon 5600 series microprocessors)

49Y1528    
7 Front bezel (all models) 46D1141    
8 Control panel (front bezel) (all models) 46D1120    
9 Hard disk drive, 2.5 inch hot-swap SAS 73 GB, 10K, (option) 43W7537    
9 Hard disk drive, 2.5 inch hot-swap SAS 73 GB, 15K, (option) 43W7546    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 73 GB, 15K 6Gbps (option) 42D0673    
9 Hard disk drive, 2.5 inch hot-swap SAS 146 GB, 10K (option) 43W7538    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 146 GB, 10K 6Gbps (option) 42D0633    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 146 GB, 15K 6Gbps (option) 42D0678    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 160 GB, 7200 (option) 42D0748    
9 Hard disk drive, 2.5 inch hot-swap SATA 300 GB, 10K (option) 43W7673    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 300 GB, 10K 6Gbps (option) 42D0638    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 500 GB, 7200 (option) 42D0753    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 500 GB, 7200 6Gbps NL (option) 42D0708    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SAS 900 GB, 10000 6Gbps NL (option) 81Y9651    
9 Hard disk drive, 2.5 inch SFF slim hot-swap SATA 500 GB, 7200 NL (option) 42D0753    
9 Solid state drive, 2.5 inch hot-swap SATA 31.4 GB (option) 43W7685    
9 Solid state drive, 2.5 inch slim hot-swap SATA 64 GB (option) 43W7659    
9 Solid state drive, 2.5 inch SFF slim High IOPS hot-swap SATA 50 GB (option) 43W7717    
10 Blade handle (right) included in the miscellaneous parts kit   46D1122  
11 Blade handle (left) included in the miscellaneous parts kit   46D1122  
12 Hot-swap storage-bay filler (models 1Mx, 6Mx, A2x, A4x, A5x, A7x, B3x, B4x, B5x, B6x, C3x, C4x, C5x, C6x, C7x, C8x, CCx, D2x, D3x, D4x, D5x, E1Y, E2Y, E3Y, EBx, ECx, EDx, EEx, EGx, F2x, F3x, GCx, G2x, G2X, G4x, HAx, H2x, H4x, H5x, K4x, L2x, L3x, M2x, N2x, 91x, 92x) 44T2248    
13 Heat sink filler (Type 1936 model C4x) (Type 7870 models 6Mx, A2x, A4x, A5x, A6x, B3x, B4x, B5x, B6x, CCx, C3x, C4x, C5x, C6x, C7x, C8x, D2x, D3x, D4x, D5x, E1Y, E2Y, E3Y, EEx, EDx, F2x, F3x, GCx, G2x, G2X, G4x, HAx, H2x, H4x, H5x, K4x, L2x, L3x, M2x, N2x)     46C3548
14 Battery, 3.0 volt (all models) 33F8354    
15 Blade server base assembly type 1 for use with Intel Xeon 5500 series microprocessors (includes the system board without a microprocessor) (Type 1936 model C4x) (Type 7870 models 1Mx, 2Mx, 3Mx, 5Mx, 6Mx, A2x, A4x, B3x, B4x, C3x, C4x, CCx, D2x, D3x, EBx, ECx, EDx, EEx, L2x, L3x, M2x)     00AE742
15 Blade server base assembly type 2 for use with Intel Xeon 5600 series and 5500 series microprocessors (includes the system board without a microprocessor) (all models)     00AE735
16 Expansion card, 4 GB Fibre Channel CIOv (option) 49Y4237    
16 Expansion card, 8 GB Fibre Channel CIOv (option) 44X1948    
16 Expansion card, Emulex 8 Gb Fibre Channel Dual-Port CIOv (option) 46M6138    
16 Expansion card, Gigabit Ethernet CIOv (option) 44W4487    
16 Expansion card, LSI 1078 RAID with battery backed cache CIOv (model ECx) 69Y1916    
16 Expansion card, LSI 1078 Stingray RAID Controller (option) 46C9241    
16 Expansion card, SAS passthrough CIOv (option) 46C4069    
16 Expansion card, Qlogic 4 Gb Fibre Channel CIOv (option) 49Y4237    
16 Expansion card, 10GbE DP (model D5x) 42C1812    
16 Expansion card, LSI Logic 1078 Stingray MegaRAID for BladeCenter (model ECx) 46C7171    
  Alcohol Kit (all models)     59P4739
  Alcohol Wipe Kit, Canada, Eng/Fr 41Y8746    
  Alcohol Wipe Kit, Brazil/Mexico 41Y8747    
  Alcohol Wipe Kit, Taiwan/Japan 41Y8748    
  Alcohol Wipe Kit, China/Malaysia 41Y8749    
  Alcohol Wipe Kit, Austrailia/UK 41Y8750    
  Alcohol Wipe Kit, Korea 41Y8751    
  Alcohol Wipe Kit, Other Countries 41Y8752    
  Alcohol Wipe Kit, Hungary 41Y8753    
  Alcohol Wipe Kit, Latin America 41Y8754    
  Alcohol Wipe Kit, China 41Y8757    
  Alcohol Wipe Kit, Hong Kong 41Y8758    
  Alcohol Wipe Kit, India 41Y8759    
  Alcohol Wipe Kit, Singapore 41Y8760    
  Battery, ServeRAID MR10ie (CIOv) controller battery 46C9242    
  Emulex Advanced Virtual Fabric Adapter (CFFh) for BladeCenter (model AC1) 49Y4261    
  Grease Kit (all models)     41Y9292
  IBM USB key for VMware ESXi 42D0545    
  Jumper cable, 12 volt (option) 46M6763    
  Kit, miscellaneous parts (all models)   46D1122  
  Label, system service (all models) 46D1121    
  Label, FRU list (all models) 46D1123    
  Microprocessor extraction tool (option) 81Y9398    
  PCI I/O expansion unit III 43W4390    
  RID tag (all models) 81Y9389    
  W2008 SP2 32/64 bit, multilingual 60Y1760    
  W2008 32/64 bit, multilingual 49Y0222    
  W2008 32/64 bit, Simplified Chinese 49Y0223    
  W2008 32/64 bit, Traditional Chinese 49Y0224    
  W2008 Standard Edition 32/64 bit 1-4 microprocessors, multilingual 49Y0892    
  W2008 Standard Edition 32/64 bit 1-4 microprocessors, Simplified Chinese 49Y0893    
  W2008 Standard Edition 32/64 bit 1-4 microprocessors, Traditional Chinese 49Y0894    
  W2008 Extended Standard Edition 32/64 bit 1-8 microprocessors, multilingual 49Y0895    
  W2008 Extended Standard Edition 32/64 bit SP2 1-8 microprocessors, Simplified Chinese 49Y0896    
  W2008 Extended Standard Edition 32/64 bit 1-8 microprocessors, Traditional Chinese 49Y0897    
  W2008 HPC Server 1-4 microprocessors, English 68Y9455    
  W2008 HPC Server 1-4 microprocessors, Japanese 68Y9456    
  W2008 HPC Server 1-4 microprocessors, Simplified Chinese 68Y9457    
  VMware ESXi3.5 U5 without USB module 68Y9633    
  VMware ESXi4.0 U1 without USB module 68Y9634    
  VMware ESXi4.1 SW without USB module 81Y2028    
  VMware ESX server 3i recovery CD kit, version 3.5 46D0762    
  VMware ESX server 3i recovery CD kit, version 3.5 update 2 46M9236    
  VMware ESX server 3i recovery CD kit, version 3.5 update 3 46M9237    
  VMware ESX server 3i recovery CD kit, version 3.5 update 4 46M9238    
  VMware ESXi 4 49Y8747