Microprocessor: Supports
up to two multi-core Intel Xeon microprocessors
Note: Use
the Setup utility to determine the type and speed of the microprocessors
in the blade server.
Integrated functions:
- Horizontal-compact-form-factor (CFFh) expansion card interface
- Vertical-combination-I/O (CIOv) expansion card interface
- Local service processor: Integrated Management Module (IMM) with
Intelligent Platform Management Interface (IPMI) firmware
- Vitesse VSC452 iBMC controller
- Integrated Matrox G200e video adapter
- LSI 1064E SAS controller
- Broadcom BCM5709S dual-port Gigabit Ethernet controller
- Integrated keyboard/video/mouse (cKVM) controller through IMM
- Light path diagnostics
- RS-485 interface for communication with the management module
- Automatic server restart (ASR)
- USB 2.0 for communication with cKVM and removable media drives
(an external USB port is not supported)
- Serial over LAN (SOL)
- Redundant buses for communication with keyboard, mouse, and removable
media drives
Predictive Failure Analysis (PFA)
alerts:
- Microprocessors
- Memory
- Storage drives
|
Memory:
- 18 dual inline memory module (DIMM) connectors
- Type: Very Low Profile (VLP) double-data rate (DDR3)
DRAM. Supports 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB DIMMs with up to
288 GB of total memory on the system board
Electrical input: 12 V dc
Environment:
- Air temperature:
- Blade server on: 10°C to 35°C (50°F to 95°F). Altitude: 0 m to
914.4 m (0 ft to 3000 ft)
- Blade server on: 10°C to 32°C (50°F to 89.6°F). Altitude: 914.4
m to 2133.6 m (3000 ft to 7000 ft)
- Blade server off: 10°C to 43°C (50°F to 109.4°F). Altitude: 914.4
m to 2133.6 m (3000 ft to 7000 ft)
- Blade server storage: 1°C to 60°C (34 to 140°F)
- Blade server shipping: -40°C to 60°C (-40°F to 140°F)
- Humidity:
- Blade server on: 8% to 80%
- Blade server off: 8% to 80%
- Blade server storage: 5% to 80%
- Blade server shipment: 5% to 100%
- Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or in combination with other environmental
factors such as humidity or temperature might pose a risk to the server.
For information about the limits for particulates and gases, see Particulate contamination.
|
Drives: Supports up to two solid state
drives (SSD)
Size:
- Height: 24.5 cm (9.7 inches) (6U)
- Depth: 44.6 cm (17.6 inches)
- Width: 2.9 cm (1.14 inches)
- Maximum weight: 4.8 kg (10 lb)
NEBS Environment:
- Air temperature:
- Blade server on: 5°C to 40°C (41°F to 104°F). Altitude: -60 m
to 1800 m (-197 ft to 6000 ft)
- Blade server on: 5°C to 30°C (41°F to 86°F). Altitude: 1800 m
to 4000 m (6000 ft to 13000 ft)
- Blade server off: -5°C to 55°C (23°F to 131°F). Altitude: -60
m to 1800 m (-197 ft to 6000 ft)
- Blade server off: -5°C to 45°C (23°F to 113°F). Altitude: 1800
m to 4000 m (6000 ft to 13000 ft)
- Blade server storage: -40°C to 60°C (-40°F to 140°F)
- Humidity: 8% to 85%
- Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or in combination with other environmental
factors such as humidity or temperature might pose a risk to the server.
For information about the limits for particulates and gases, see Particulate contamination.
|