405-000-xxx |
Passed the EEPROM test on the system board. |
N/A |
405-001-xxx |
Passed the MII registers test. |
N/A |
405-002-xxx |
Passed the EEPROM test on the system board. |
N/A |
405-003-xxx |
Passed the Internal memory test. |
N/A |
405-004-xxx |
Passed the interrupt test. |
N/A |
405-005-xxx |
Passed the MAC layer loopback test. |
N/A |
405-007-xxx |
Passed LED test. |
N/A |
405-901-xxx |
Test control registers. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-902-xxx |
Failed the MII registers test. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-903-xxx |
Failed the EEPROM test on the system board. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-904-xxx |
Failed the Internal memory test. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-905-xxx |
Failed interrupt test. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, check interrupt assignments in the PCI
Hardware section of the DSA Diagnostic Log. If the Ethernet device
is sharing interrupts, modify the interrupt assignments using the
Setup utility to assign a unique interrupt to the device (see Using the Setup utility).
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-906-xxx |
Failed MAC layer loopback test. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, check interrupt assignments in the PCI
Hardware section of the DSA Diagnostic Log. If the Ethernet device
is sharing interrupts, modify the interrupt assignments using the
Setup utility to assign a unique interrupt to the device (see Using the Setup utility).
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-908-xxx |
Failed LED test. |
- Make sure that the component firmware level is up-to-date, upgrade
if necessary; then, rerun the test. The installed firmware level can
be found in the DSA Diagnostic Event Log within the Firmware/VPD section
for this component. The latest level firmware for this component can
be found on the IBM support Web site at http://www.ibm.com/support/docview.wss?uid=psg1MIGR-63017.
- If the failure remains, check interrupt assignments in the PCI
Hardware section of the DSA Diagnostic Log. If the Ethernet device
is sharing interrupts, modify the interrupt assignments using the
Setup utility to assign a unique interrupt to the device (see Using the Setup utility).
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|