In-band manual recovery method

To recover the server firmware and restore the server operation to the primary bank, complete the following steps:
  1. Download the blade server UEFI firmware update from the World Wide Web (see Firmware updates).
  2. Turn off the server (see Turning off the blade server).
  3. Remove the blade server from the BladeCenter unit (see Removing the blade server from the BladeCenter unit).
  4. Remove the server cover. See Removing the blade server cover for more information.
  5. Locate the UEFI boot block recovery switch (SW1-5) on the system board (see System-board switches).
  6. Use your finger to move switch SW1-5 to the ON position.
  7. Replace the cover and reinstall the blade server in the BladeCenter unit, making sure that the media tray is selected by the relevant blade server. See Closing the blade server cover and Installing the blade server in a BladeCenter unit.
  8. Restart the blade server (see Turning on the blade server). The system begins the power-on self-test (POST).
  9. Boot the server to an operating system that is supported by the firmware update package that you downloaded.
  10. Perform the firmware update by following the instructions that are in the firmware update package readme file.
  11. Copy the downloaded firmware update package into a directory.
  12. From a command line, type filename-s, where filename is the name of the executable file that you downloaded with the firmware update package.
  13. Reboot the server and verify that it completes POST (see Turning off the blade server and Turning on the blade server).
  14. Turn off the server (see Turning off the blade server).
  15. Remove the blade server form the BladeCenter unit (see Removing the blade server from the BladeCenter unit).
  16. Remove the server cover. See Removing the blade server cover.
  17. Move the UEFI boot block recovery switch (SW1-5) to the OFF position (see System-board switches).
  18. Replace the cover and reinstall the blade server in the BladeCenter unit, making sure that the media tray is selected by the relevant blade server. See Closing the blade server cover and Installing the blade server in a BladeCenter unit.
  19. Restart the blade server (see Turning off the blade server and Turning on the blade server). The system begins the power-on self-test (POST).If this does not recover the primary bank continue with the following steps.
  20. Remove the blade server form the BladeCenter unit (see Removing the blade server from the BladeCenter unit).
  21. Remove the server cover. See Removing the blade server cover.
  22. Reset the CMOS by removing the battery (see Removing the battery).
  23. Leave the battery out of the server for 5 minutes.
  24. Reinstall the battery (see Installing the battery).
  25. Replace the cover and reinstall the blade server in the BladeCenter unit, making sure that the media tray is selected by the relevant blade server. See Closing the blade server cover and Installing the blade server in a BladeCenter unit.
  26. Restart the blade server (see Turning on the blade server).

The system begins the power-on self-test (POST).