Use this information to locate and identify the light path
diagnostics LEDs.
Before you work inside the blade server to view light
path diagnostics LEDs, read Safety and Installation guidelines.
If an error occurs,
view the light path diagnostics LEDs in the following order:
- Look at the control panel on the front of the blade server
(see Blade server controls and LEDs).
- If the information LED is lit, it indicates that information about
a suboptimal condition in the blade server is available in the IMM2
log or in the Advanced-Management-Module event log.
- If the blade-error LED is lit, it indicates that an error has
occurred; view the light path diagnostics panel (located under the
blade server) and LEDs on the system board to isolate the failing
component.
- To view the light path diagnostics
panel and LEDs, complete the following steps:
- Remove the blade server from the BladeCenter unit. See Removing the blade server from the BladeCenter unit.
- Place the blade server, bottom side up, on a flat, static-protective
surface.
- Press and hold the power button to light the LEDs on
the light path diagnostics panel.
- If the INTERNAL LP LED is lit, it indicates that an
error has occurred on a component on the system board. Complete the
following steps:
- Remove the cover from the blade server. See Removing the blade server cover.
- Press and hold the power button to light the LEDs of the failing
components in the blade server. The LEDs will remain lit for as long
as you press the switch, to a maximum of 25 seconds.
The following illustration shows
the locations of the system-board error LEDs.
The following illustration
shows the light path diagnostics panel under the blade server.