405-000-xxx |
Passed the ControlRegisters test. |
N/A |
405-901-xxx |
Failed the ControlRegisters test. A failure was
detected while testing internal MAC registers. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-001-xxx |
Passed the MIIRegisters test. |
N/A |
405-901-xxx |
Failed the MIIRegisters test. A failure was detected
while testing internal PHY registers. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-002-xxx |
Passed the EEPROM test. |
N/A |
405-902-xxx |
Failed the EEPROM test. A failure was detected
while testing non-volatile RAM. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-003-xxx |
Passed the InternalMemory test. |
N/A |
405-903-xxx |
Failed the InternalMemory test. A failure was detected
while testing internal memory. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-004-xxx |
Passed the Interrupt test. |
N/A |
405-904-xxx |
Failed the Interrupt test. A failure was detected
while testing interrupts. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-005-xxx |
Passed the LoopbackAtMACLayer test. |
N/A |
405-905-xxx |
Failed the LoopbackAtMACLayer test. A failure was
detected during the loopback test at the MAC layer. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-006-xxx |
Passed the LoopbackAtPhysicallayer test. |
N/A |
405-906-xxx |
Failed the LoopbackAtPhysicallayer test. A failure
was detected during the loopback test at the physical layer. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|
405-006-xxx |
Passed the LEDs test. |
N/A |
405-906-xxx |
Failed the LEDs test. A failure was detected while
verifying operation of the status LEDs. |
- Make sure that the component firmware or driver is installed correctly,
upgrade if necessary. The installed firmware level can be found in
the DSA Diagnostic Event Log within the Firmware/VPD section for this
component. The latest level firmware for this component can be found
in reference to this system type at http://www.ibm.com/ support/docview.wss?
uid=psg1MIGR-4JTS2T.
- Rerun the test.
- If the failure remains, refer to http://www.ibm.com/ support/docview.wss?
uid=psg1SERV-OPTN for the corrective actions.
|