Microprocessor: Supports up to two multi-core
IntelXeon microprocessors.
Note: Use the Setup utility to determine
the type and speed of the microprocessors in the blade server.
Memory:
- 12 dual inline memory module (DIMM) connectors
- Type: Very Low Profile (VLP) double-data rate (DDR3) single-rank,
dual-rank, or quad-rank DRAM
- Supports 2 GB, 4 GB, 8 GB, and 16 GB DIMMs with up to 192 GB of
total memory on the system board
Integrated functions:
- Horizontal-compact-form-factor (CFFh) expansion card interface
- Vertical-combination-I/O (CIOv) expansion card interface
- Local service processor: Integrated Management Module II (IMM2)
with Intelligent Platform Management Interface (IPMI) firmware
- Integrated Renesas SH7757 IMM2 video controller
- Integrated keyboard/video/mouse (cKVM) controller through the
IMM2
- Light path diagnostics
- RS-485 interface for communication with the management module
- USB 2.0 for communication with cKVM and removable media drives
(an external USB port is not supported)
- Serial over LAN (SOL)
- Wake on LAN (WOL)
- Redundant buses for communication with keyboard, mouse, and removable
media drives
|
Predictive Failure Analysis (PFA) alerts:
- Memory
- Storage drives (SAS only)
Electrical input: 12 V dc
Environment:
- Air temperature:
- Blade server on: 10°C to 35°C (50°F to 95°F). Altitude: 0 m to
914.4 m (0 ft to 3000 ft)
- Blade server on: 10°C to 32°C (50°F to 89.6°F). Altitude: 914.4
m to 2133.6 m (3000 ft to 7000 ft)
- Blade server off: 10°C to 43°C (50°F to 109.4°F). Altitude:
914.4 m to 2133.6 m (3000 ft to 7000 ft)
- Blade server shipping: -40°C to 60°C (-40°F to 140°F)
- Humidity:
- Blade server on: 8% to 80%
- Blade server off: 8% to 80%
- Blade server storage: 5% to 80%
- Blade server shipment: 5% to 100%
- Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or in combination with other environmental
factors such as humidity or temperature might pose a risk to the server.
For information about the limits for particulates and gases, see Particulate contamination.
|
Drives: Supports up to two hot-swap,
small form factor (SFF)
- Serial Attached SCSI (SAS) (enabled when ServeRAID H1135 is installed)
- Serial ATA (SATA) (including solid-state storage drives)
Size:
- Height: 24.5 cm (9.64 inches) (6U)
- Depth: 44.6 cm (17.56 inches)
- Width: 2.9 cm (1.14 inches)
- Maximum weight: 4.63 kg (10.2 lb)
|