405-000-xxx |
Passed the EEPROM test on the system board. |
|
405-001-xxx |
Passed the MII registers test. |
|
405-002-xxx |
Passed the EEPROM test on the system board. |
|
405-003-xxx |
Passed the internal memory test |
|
405-004-xxx |
Passed the interrupt test. |
|
405-005-xxx |
Passed the MAC layer loopback test. |
|
405-007-xxx |
Passed LED test. |
|
405-901-xxx |
Failed the Broadcom Ethernet tests due to a failure
in the internal registers |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again. See Diagnostic tools overview.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-902-xxx |
Failed the Broadcom Ethernet tests due to a failure
in non-volatile RAM |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again. See Diagnostic tools overview.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-903-xxx |
Failed the Broadcom Ethernet tests due to a failure
in internal memory |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again. See Diagnostic tools overview.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-904-xxx |
Failed the Broadcom Ethernet tests due to a failure
in interrupts |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-905-xxx |
Failed the Broadcom Ethernet tests due to a failure
in loopback test at MAC layer. |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again. See Diagnostic tools overview.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-906-xxx |
Failed the Broadcom Ethernet tests due to a failure
in loopback test at physical layer. |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again. See Diagnostic tools overview.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|
405-907-xxx |
Failed the Broadcom Ethernet tests due to a failure
in status LED operation. |
- Make sure that the component firmware level is up-to-date, and
upgrade if necessary. The installed firmware level can be found in
the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be at http://www.ibm.com/support/
fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
- Run the test again. See Diagnostic tools overview.
- If the failure remains, refer to Removing and replacing blade server components to
replace the failed component.
|