Carefully lay the blade server on a
flat, static-protective surface.
If you are installing the SSD expansion card in a blade server that is the bottom blade server in an
existing scalable blade complex, disassemble the blade complex (see Disassembling a scalable blade complex for
instructions).
If an optional expansion unit is installed,
remove the expansion unit (see Removing an expansion unit for instructions).
Note: Optional expansion units are not supported when a IBM MAX5 expansion
blade is installed.
Insert the back of the SSD expansion card into the expansion-card standoffs on the blade server
and rotate the expansion card down toward the system board.
Note: The expansion card standoff in the middle
of the blade server has two slots. The top slot is for the CFFh expansion
card. Be sure to insert the SSD expansion card into the bottom slot of the expansion-card standoff that
is located in the middle of the blade server.
Carefully push down on the SSD expansion card (pressing on the blue label) until the expansion card
is seated.
Note: Make sure that the expansion card lever is in the closed
position.
Install the CFFh expansion card, if you removed one from
the blade server (see Installing a CFFh expansion card for instructions).
If the blade server is
part of a scalable blade complex, assemble the scalable blade complex
(see Assembling a scalable blade complex for instructions).