To recover the server firmware and restore the server operation
to the primary bank, complete the following steps:
- Download the blade server UEFI firmware update from the
World Wide Web (see Updating firmware and device drivers).
- Turn off the server (see Turning off the blade server).
- Remove the blade server from the BladeCenter unit (see Removing the blade server from the BladeCenter chassis).
- Remove the server cover. See Removing the blade server cover for more
information.
- Locate the UEFI boot block recovery switch (SW2-7) on
the system board (see System-board switches).
- Use your finger to move switch SW2-7 to the ON position.
- Replace the cover and reinstall the blade server in the
BladeCenter unit, making sure that the media tray is selected by the
relevant blade server. See Installing the blade server cover and Installing a blade server in a BladeCenter chassis.
- Restart the blade server (see Turning on the blade server). The system begins the power-on self-test (POST).
- Boot the server to the operating system or the F1 UEFI
configuration menu.
- Log into the Advanced Management's web interface.
- After you log in, select MM Control -> Network Protocol and ensure that TFTP is enabled on the management module. The default
setting is disable.
- Select Blade Tasks -> Firmware update and select
the blade server you want to recover.
- Use the browse button to point to the UEFI update file.
- Click the Update button to update the UEFI firmware.
- Reboot the server and verify that it completes POST (see Turning off the blade server and Turning on the blade server).
- Turn off the server (see Turning off the blade server).
- Remove the blade server form the BladeCenter unit (see Removing the blade server from the BladeCenter chassis).
- Remove the server cover. See Removing the blade server cover.
- Move the UEFI boot block recovery switch (SW2-7) to the
OFF position (see System-board switches).
- Replace the cover and reinstall the blade server in the
BladeCenter unit, making sure that the media tray is selected by the
relevant blade server. See Installing the blade server cover and Installing a blade server in a BladeCenter chassis.
- Restart the blade server (see Turning off the blade server and Turning on the blade server). The system begins the power-on self-test (POST). If this
does not recover the primary bank continue with the following steps.
- Remove the blade server form the BladeCenter unit (see Removing the blade server from the BladeCenter chassis).
- Remove the server cover. See Removing the blade server from the BladeCenter chassis.
- Reset the CMOS by removing the battery (see Removing the battery).
- Leave the battery out of the server for 5 minutes.
- Reinstall the battery (see Installing the battery).
- Replace the cover and reinstall the blade server in the
BladeCenter unit, making sure that the media tray is selected by the
relevant blade server. See Installing the blade server cover and Installing a blade server in a BladeCenter chassis.
- Restart the blade server (see Turning on the blade server).
The system begins the power-on self-test (POST).