power command errors

This topic lists error messages for the power command.

See Common errors for a list of error messages that apply to all commands.

Table 1. power command errors
Error message Definition
Invalid POST results. The POST results are not valid.
Not supported by this type of I/O module. Type env -h for help on changing targets. The user attempts to apply the -fp option to an I/O module that does not support this option.
POST results could not be read. An error occurs during POST.
POST results not complete: hex_code

where the hex_code value varies based on the problem that was encountered.

The POST results are not available. See the documentation that comes with the device that failed to respond correctly to the power command for information about the hex_code value.
Powering on/off blade failed. An error occurs while powering the blade server on or off.
Powering on/off I/O Module failed. An error occurs while the management module is powering the I/O module on or off.
Resetting blade failed. An error occurs while the management module is resetting the blade server.
Shutting down OS and powering off blade failed. An error occurs while the management module is shutting down the operating system and powering off the blade server.