This topic lists error messages for the update command.
See Common errors for a list of error messages that apply to all commands.
Error message | Definition |
---|---|
Cannot perform this command right now. The agent is not active. | A user tries to enter a command while the agent is not active. |
Disabling failover failed. | An error occurs while the management module is turning off the automatic failover feature. |
Error reading information for firmware image index.maximum
where index specifies the firmware image. |
An error occurs while the management module is reading information for a specified firmware image. |
Error reading the number of firmware images. | An error occurs while the management module is reading the number of firmware images. |
Flash operation failed. | An error occurs during the flash firmware update. |
Flash operation failed status percentage
where the percentage value varies based on when the problem was encountered. |
An error occurs during the flash firmware update. |
Flash operation not in process or status unavailable. | An error occurs during the flash firmware update. |
Flash operation timed out percentage. where the percentage value varies based on when the problem was encountered. |
An error occurs during the flash firmware update. |
Flash preparation - error sending packet file filename. where filename identifies the file being updated. |
An error occurs during the flash firmware update. |
Flash preparation error. Packet percent complete percentage.
Flash percent complete percentage. where the percentage value varies based on when the problem was encountered. |
An error occurs during the flash firmware update. |
Flash preparation error. Timeout on packet preparation
operation percentage. where the percentage value varies based on when the problem was encountered. |
An error occurs during the flash firmware update. |
Flashing not supported on this target. | A user attempts to run the update command on a module that does not support flash firmware updates. |
Getting data encryption setting failed. If data encryption is enabled and you are updating the firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. | An error occurs while the management module is reading the data encryption setting. |
Getting name of mm bay_number failed. where the bay_number identifies the management module specified. |
An error occurs while the management module is reading the name of the management module in designated bay. |
Invalid image index. Index must be less than maximum
where maximum designates the largest permitted index value. |
A user tries to enter an image index that is greater than the maximum permitted index value. |
Invalid option. | An invalid command option is entered. For the update command,
invalid command option errors include:
|
Management Module bay_number is not installed. where the bay_number identifies the management module specified. |
The command is targeted to a management module bay where no management module is installed. |
Status: Unable to read status. | An error occurs while the management module is reading status. |
TFTP Error: error_code. where the error_code can have one of the following values:
|
An error occurs when the user attempts to set up the TFTP connection. |
Unable to read blade server VPD bay bay_number
name.
where the bay_number and name identify the blade server by location and name. |
The command specifies an empty blade server bay or an error occurs when reading the VPD. |
Unable to read I/O Module VPD bay bay_number
name.
where the bay_number and name identify the I/O module by location and name. |
The command specifies an empty I/O-module bay or an error occurs when reading the VPD. |
Unable to read MM VPD bay bay_number
name.
where the bay_number and name identify the management module by location and name. |
The command specifies an empty management module bay or an error occurs when reading the VPD. |
Unable to read VPD for Blade blade_number
name. where the blade_number and name identify the blade server by location and name. |
An error occurs while the management module is reading the VPD of the targeted blade server. |
Unknown device type. | The command is targeted to an unknown device type. |
Update error. Invalid destination. | A user tries to issue a command to a target that is not valid. |
Update Failed, there was a problem retrieving the file. | The management module was unable to complete the update because it was unable to retrieve the file from the TFTP server. |