An A1xxyyyy system reference code (SRC) is an attention code that offers information about a platform or service processor dump or confirms a control panel function request. Take the steps in the Action column only if the BladeSystem appears to hang on an attention code.
Table 1 shows A1xxyyyy SRCs.
Attention code | Description | Action |
---|---|---|
A1xxyyyy | Attention code |
|
An A2xxyyyy SRC is a logical partition reference code that is related to logical partitioning.
Reference Code | Description | Action |
---|---|---|
A2xxyyyy | See the description for the B200yyyy error code with the same yyyy value. | Perform the action described in the B200yyyy error code with the same yyyy value. |
A2D03000 | User-initiated immediate termination and MSD of a partition. | No corrective action is required. |
A2D03001 | User-initiated RSCDUMP of RPA partition's PFW content. | No corrective action is required. |
A2D03002 | User-initiated RSCDUMP of IBM i partition's SLIC bootloader and PFW content. | No corrective action is required. |
An A700xxxx system reference code (SRC) is an error/event code that is related to licensed internal code.
Reference Code | Description | Action |
---|---|---|
A700173C | Informational system log entry only. | No corrective action is required. |
A7003000 | A user-initiated platform dump occurred. | No service action required. |
A7004700 | Informational system log entry only. | No corrective action is required. |
A7004712 | A problem occurred when initializing, reading, or using system VPD. | Replace the management card, as described in Removing the tier 2 management card and Installing the tier 2 management card. |
A7004713 | A problem occurred when initializing, reading, or using system VPD. | Replace the management card, as described in Removing the tier 2 management card and Installing the tier 2 management card. |
A7004715 | A problem occurred when initializing, reading, or using system VPD. | Replace the management card, as described in Removing the tier 2 management card and Installing the tier 2 management card. |
A7004721 | The World Wide Port Name (WWPN) Prefix is not valid. | https://www-912.ibm.com/supporthome.nsf/document/51455410 |
A7004730 | Informational system log entry only. | No corrective action is required. |
A7004740 | Informational system log entry only. | No corrective action is required. |
A7004741 | Informational system log entry only. | No corrective action is required. |
A7004788 | Informational system log entry only. | No corrective action is required. |
A70047FF | Informational system log entry only. | No corrective action is required. |
A7013003 | Partition-initiated PHYP-content RSCDUMP. | No corrective action is required. |
A700yyyy | For any other A7xxyyyy SRC not listed here, see the description for the B7xxyyyy error code with the same xxyyyy value. | Perform the action in the B7xxyyyy error code with the same xxyyyy value. |