A1xxyyyy service processor SRCs

An A1xxyyyy system reference code (SRC) is an attention code that offers information about a platform or service processor dump or confirms a control panel function request. Take the steps in the Action column only if the BladeSystem appears to hang on an attention code.

Table 1 shows A1xxyyyy SRCs.

Table 1. A1xxyyyy service processor SRCs
Attention code Description Action
A1xxyyyy Attention code
  1. Go to Checkout procedure.
  2. Replace the system board and chassis assembly, as described in Replacing the FRU system-board and chassis assembly.

A2xxyyyy Logical partition SRCs

An A2xxyyyy SRC is a logical partition reference code that is related to logical partitioning.

Table 2. A2xxyyyy Logical partition SRCs
Reference Code Description Action
A2xxyyyy See the description for the B200yyyy error code with the same yyyy value. Perform the action described in the B200yyyy error code with the same yyyy value.
A2D03000 User-initiated immediate termination and MSD of a partition. No corrective action is required.
A2D03001 User-initiated RSCDUMP of RPA partition's PFW content. No corrective action is required.
A2D03002 User-initiated RSCDUMP of IBM i partition's SLIC bootloader and PFW content. No corrective action is required.

A700yyyy Licensed internal code SRCs

An A700xxxx system reference code (SRC) is an error/event code that is related to licensed internal code.

Table 3. A700yyyy Licensed internal code SRCs
Reference Code Description Action
A700173C Informational system log entry only. No corrective action is required.
A7003000 A user-initiated platform dump occurred. No service action required.
A7004700 Informational system log entry only. No corrective action is required.
A7004712 A problem occurred when initializing, reading, or using system VPD. Replace the management card, as described in Removing the tier 2 management card and Installing the tier 2 management card.
A7004713 A problem occurred when initializing, reading, or using system VPD. Replace the management card, as described in Removing the tier 2 management card and Installing the tier 2 management card.
A7004715 A problem occurred when initializing, reading, or using system VPD. Replace the management card, as described in Removing the tier 2 management card and Installing the tier 2 management card.
A7004721 The World Wide Port Name (WWPN) Prefix is not valid. https://www-912.ibm.com/supporthome.nsf/document/51455410
A7004730 Informational system log entry only. No corrective action is required.
A7004740 Informational system log entry only. No corrective action is required.
A7004741 Informational system log entry only. No corrective action is required.
A7004788 Informational system log entry only. No corrective action is required.
A70047FF Informational system log entry only. No corrective action is required.
A7013003 Partition-initiated PHYP-content RSCDUMP. No corrective action is required.
A700yyyy For any other A7xxyyyy SRC not listed here, see the description for the B7xxyyyy error code with the same xxyyyy value. Perform the action in the B7xxyyyy error code with the same xxyyyy value.