Location codes

Location codes identify components of the blade server. Location codes are displayed with some error codes to identify the blade server component that is causing the error.

See System-board connectors for component locations.

Notes:
  1. Location codes do not indicate the location of the blade server within the BladeCenter® unit. The codes identify components of the blade server only.
  2. For checkpoints with no associated location code, see Light path diagnostics to identify the failing component when there is a hang condition.
  3. For checkpoints with location codes, use the following table to identify the failing component when there is a hang condition.
  4. For 8-digit codes not listed in Table 1, see the Checkout procedure.
Table 1. Location codes for PS703.
Components Physical location code CRU LED
Un location codes are for enclosure and VPD locations.
Un = Utttt.mmm.sssssss

tttt = system machine type
mmm = system model number
sssssss = system serial number

DIMM 1 Un-P1-C1 Yes
DIMM 2 Un-P1-C2 Yes
DIMM 3 Un-P1-C3 Yes
DIMM 4 Un-P1-C4 Yes
DIMM 5 Un-P1-C5 Yes
DIMM 6 Un-P1-C6 Yes
DIMM 7 Un-P1-C7 Yes
DIMM 8 Un-P1-C8 Yes
DIMM 9 Un-P1-C9 Yes
DIMM 10 Un-P1-C10 Yes
DIMM 11 Un-P1-C11 Yes
DIMM 12 Un-P1-C12 Yes
DIMM 13 Un-P1-C13 Yes
DIMM 14 Un-P1-C14 Yes
DIMM 15 Un-P1-C15 Yes
DIMM 16 Un-P1-C16 Yes
2.5" SAS disk drive Un-P1-D1 Yes
Management card Un-P1-C17 Yes
Solid-state drive carrier Un-P1-C18 Yes
Solid-state drive 1 (top drive) Un-P1-C18-D1 Yes
Solid-state drive 2 (bottom drive) Un-P1-C18-D2 Yes
Battery Un-P1-E1 Yes
CFFh expansion card Un-P1-C20 Yes
CIOv form-factor expansion card Un-P1-C19 Yes
USB port 1 (CDROM/FDD) Un-P1-T1 No
USB port 2 (CDROM/FDD) Un-P1-T2 No
Ethernet port 0 Un-P1-T3 No
Ethernet port 1 Un-P1-T4 No
Integrated SAS controller Un-P1-T5 No
Machine location code Utttt.mmm.sssssss No
Um codes are for firmware. The format is the same as for a Un location code.

Um = Utttt.mmm.sssssss

Firmware version Um-Y1
Table 2. Location codes for PS704
Components Physical location code CRU LED
Un location codes are for enclosure and VPD locations.
Un = Utttt.mmm.sssssss

tttt = system machine type
mmm = system model number
sssssss = system serial number

DIMM 1 Un-P1-C1 Yes
DIMM 2 Un-P1-C2 Yes
DIMM 3 Un-P1-C3 Yes
DIMM 4 Un-P1-C4 Yes
DIMM 5 Un-P1-C5 Yes
DIMM 6 Un-P1-C6 Yes
DIMM 7 Un-P1-C7 Yes
DIMM 8 Un-P1-C8 Yes
DIMM 9 Un-P1-C9 Yes
DIMM 10 Un-P1-C10 Yes
DIMM 11 Un-P1-C11 Yes
DIMM 12 Un-P1-C12 Yes
DIMM 13 Un-P1-C13 Yes
DIMM 14 Un-P1-C14 Yes
DIMM 15 Un-P1-C15 Yes
DIMM 16 Un-P1-C16 Yes
2.5" SAS disk drive Un-P1-D1 Yes
Management card Un-P1-C17 Yes
Solid-state drive carrier Un-P1-C18 Yes
Solid-state drive 1 (top drive) Un-P1-C18-D1 Yes
Solid-state drive 2 (bottom drive) Un-P1-C18-D2 Yes
Battery Un-P1-E1 Yes
CFFh expansion card Un-P1-C20 Yes
CIOv form-factor expansion card Un-P1-C19 Yes
USB port 1 (CDROM/FDD) Un-P1-T1 No
USB port 2 (CDROM/FDD) Un-P1-T2 No
Ethernet port 0 Un-P1-T3 No
Ethernet port 1 Un-P1-T4 No
Integrated SAS controller Un-P1-T5 No
DIMM 17 Un-P2-C1 Yes
DIMM 18 Un-P2-C2 Yes
DIMM 19 Un-P2-C3 Yes
DIMM 20 Un-P2-C4 Yes
DIMM 21 Un-P2-C5 Yes
DIMM 22 Un-P2-C6 Yes
DIMM 23 Un-P2-C7 Yes
DIMM 24 Un-P2-C8 Yes
DIMM 25 Un-P2-C9 Yes
DIMM 26 Un-P2-C10 Yes
DIMM 27 Un-P2-C11 Yes
DIMM 28 Un-P2-C12 Yes
DIMM 29 Un-P2-C13 Yes
DIMM 30 Un-P2-C14 Yes
DIMM 31 Un-P2-C15 Yes
DIMM 32 Un-P2-C16 Yes
2.5" SAS disk drive Un-P2-D1 Yes
Solid-state drive carrier Un-P2-C18 Yes
Solid-state drive 1 (top drive) Un-P2-C18-D1 Yes
Solid-state drive 2 (bottom drive) Un-P2-C18-D2 Yes
CFFh expansion card Un-P2-C20 Yes
CIOv form-factor expansion card Un-P2-C19 Yes
Ethernet port 0 Un-P2-T3 No
Ethernet port 1 Un-P2-T4 No
Integrated SAS controller Un-P2-T5 No
Machine location code Utttt.mmm.sssssss No
Um codes are for firmware. The format is the same as for a Un location code.

Um = Utttt.mmm.sssssss

Firmware version Um-Y1