Recovering the TEMP image from the PERM image

To recover the TEMP image from the PERM image, you must perform the reject function. The reject function copies the PERM image into the TEMP image.

To perform the reject function, complete the following procedure.

  1. If you have not started the system from the PERM image, do so now. See Starting the PERM image.
  2. Issue the appropriate command for your operating system to reject the TEMP image.
    • If you are using the Red Hat Linux or SUSE Linux operating system, type the following command:
      update_flash -r
    • If you are using the AIX® operating system, type the following command:
      /usr/lpp/diagnostics/bin/update_flash -r
  3. Start the TEMP image, as described in Starting the TEMP image.

You might need to update the firmware code to the latest version. See Updating the firmware for more information about how to update the firmware code.