BladeCenter
What's New
Additional information sources
BladeCenter Security – Best Practices
Racks
IBM 11U Office Enablement Kit
PDF file
Introduction
Safety
Rack safety statements
IBM Statement of Limited Warranty Z125-4753-10 08/2008
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
United Kingdom telecommunications safety requirement
European Union EMC Directive conformance statement
Taiwanese Class A warning statement
Chinese Class A warning statement
Japanese Voluntary Control Council for Interference (FCS) statement
Planning
Physical dimensions and clearances
Installing
Installation considerations
Installation guidelines
System reliability guidelines
Setting up the Office Enablement Kit
Removing the Office Enablement Kit from the pallet
Removing the front door
Installing the stabilizer bracket
Extending the stabilizer bracket
Installing optional devices
Installing an uninterruptible power supply
Installing a System x server
Installing a BladeCenter chassis
Shipping a BladeCenter S chassis
Installing a flat-panel monitor console kit
Installing a blank filler panel
Installing the front door
Installing the rear door
Managing cables
Removing and replacing components
Parts listing
Replacing a door lock
Replacing the hinge bracket and door latch
Replacing casters
Replacing the stabilizer bracket assembly
Getting help and technical assistance
Before you call
Hardware service and support
Software service and support
IBM Taiwan product service
Chassis
BladeCenter E (8677)
Planning
Installing
Troubleshooting
Warranty
Options
BladeCenter T (8720/8730)
Planning
Installing
Troubleshooting
Warranty
Options
BladeCenter HT (8740/8750)
Installing
Troubleshooting
Warranty
Options
BladeCenter H (8852)
Installing
Troubleshooting
Warranty
Options
BladeCenter S (8886/7779)
PDF files
Product overview
Features and specifications
Components
Front view
Disk storage module
Media tray
Battery backup unit
Blade server
Rear view
Advanced management module - BladeCenter S Types 7779 and 8886
Indicators and controls
Input and output connectors
Serial pass-thru module
I/O modules
Power modules
Fan modules
Systems and storage management
IBM Director
Storage Configuration Manager
Safety
Guidelines for servicing electrical equipment
Inspecting for unsafe conditions
Safety statements
IBM Statement of Limited Warranty Z125-4753-10 08/2008
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Learning and tutorials
Introducing the BladeCenter S Type 8886
Configuring your BladeCenter S system
Configuring your BladeCenter S system storage
Managing your BladeCenter S system
Planning
Planning for the physical environment
Dimensions
Weight considerations
Floor space
Rack requirements
IBM NetBAY and non-IBM racks
Noise considerations
Power considerations
Power source requirements
Power consumption guidelines
Power management policies
Power allocation guidelines
Power diagrams
110 VAC
220 VAC
Cooling considerations
Air temperature and humidity
Airflow considerations
Heat output
Prevention of air recirculation
Room cooling
Deployment
Network topology
Deployment of the BladeCenter S system
Hardware for the BladeCenter S system
I/O module bay configuration options
I/O module bay 1 configuration options
I/O module bay 2 configuration options
I/O module bays 3 and 4 configuration options
Deployment tools
IBM Director
Remote Deployment Manager
IBM ServerGuide
Management connection
Deployment of blade servers
Hardware for blade servers
Operating system considerations
Application considerations
Planning for configuration
Configuration tools
BladeCenter Open Fabric Manager
Storage Configuration Manager
Keyboard, video, and mouse
Planning for advanced management module configuration
General settings
User profile settings
Alert settings
Serial port
Port settings
Ethernet network settings
Network protocols settings
Security settings
Ethernet switch module configuration planning
SAS connectivity module
User-defined configurations
Predefined configurations
Predefined storage configuration 02
Predefined storage configuration 03
Predefined storage configuration 04
Predefined storage configuration 05
Predefined storage configuration 06
Predefined storage configuration 07
Predefined storage configuration 08
Predefined storage configuration 09
SAS RAID controller module
Defining storage pools
Defining volumes
Zone for SAS RAID controller modules
Replacing SAS connectivity modules with SAS RAID controller modules
Planning worksheets
Installation planning worksheets
Blade server and workstation blade installation worksheet
BladeCenter S Types 7779 and 8886 installation worksheet
Rack installation worksheet
Cabling worksheet
Power worksheet
Configuration planning worksheets
Advanced management module configuration worksheet
SAS connectivity module configuration worksheet
SAS RAID controller module
Installing
Preparing to install your BladeCenter S system
Verifying ship group contents
Obtaining firmware and device drivers
Obtaining configuration, systems management, and storage management software
Setting up your BladeCenter S system
Removing components
Installing the BladeCenter S chassis in a rack
Rack-mounting template
Installing components
Installing the battery backup unit
Installing a disk storage module
Installing a blade server
Installing a serial pass-thru module
Installing an advanced management module
Installing a power module
Installing a fan module
Installing an I/O module
Cabling the BladeCenter S chassis
Connecting the BladeCenter S chassis to power
Disconnecting power from the BladeCenter unit
Installing IBM Director Server (optional)
Configuring
Configuring I/O modules
Configuring blade servers
Selecting shared BladeCenter resources
Troubleshooting
Service bulletins
Diagnostic tools
Light path diagnostic LEDs
System LED panel
Module LEDs
Event log
Watchdog timeout messages
I-error messages
I2C errors
Updating firmware
Isolating component failures
Symptoms by component
Advanced management module
Can ping the advanced management module but cannot access it
Cannot connect to the advanced management module
Cannot log in to the advanced management module
BIST errors
Blade servers
Blade server cannot communicate with external network
Blade server will not power on
I-error messages displayed for an Intel-based blade server
I-error messages displayed for an AMD-based blade server
Kernel mode displayed for blade server
No LEDs appear
No VPD available from advanced management module
Power LED continually flashes rapidly
Service processor communication (SP COMM) errors displayed for a blade server
Service processor communication error displayed for multiple blade servers
Watchdog timeout messages displayed for a blade server
Watchdog timeout messages displayed for multiple blade servers
Fan modules
Fan module running at full speed
Fan module is stopped
Fan modules continually cycle to full speed
I/O modules
I/O module will not power on
LEDs are not lit for an I/O module
Cannot communicate with external ports on I/O module
Blade server cannot communicate through CPM ports
Keyboard, mouse, or pointing devices
Keyboard or mouse device not working
Keyboard or mouse device not working after KVM ownership change
Media tray
Blade server cannot access the media tray
Multiple blade servers cannot access the media tray
Blade servers cannot communicate with the media tray
Monitor or video
Local and remote video not working
Remote video displays but local video does not
Local video displays but remote video does not
Power modules
BladeCenter S chassis has no power
The ac and dc LEDs are not lit for multiple power supplies
The dc LED is not lit but ac LED is lit
Fault LED is lit
Serial over LAN
Blade server does not support SoL (as reported in the advanced management module)
Blade server SoL status enabled but not ready (in management module)
SoL session will not stay up
Trouble entering commands or receiving double prompts
Characters received or typed are incorrect
Storage module
Hard disk drives not available to blade servers
Removing and replacing BladeCenter components
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Parts listing
Front view
Rear view
Power cords - C14 power module
Power cords - C20 power module
Removing and replacing CRUs
Removing a bezel
Installing a bezel
Removing the media tray
Installing the media tray
Removing the DVD drive
Installing the DVD drive
Removing the battery backup unit
Installing the battery backup unit
Removing an advanced management module
Installing an advanced management module
Removing a blade server
Installing a blade server
Removing a fan module
Installing a fan module
Removing an I/O module
Installing an I/O module
Removing a power module
Installing a power module
Removing a serial pass-thru module
Installing a serial pass-thru module
Removing a disk storage module
Installing a disk storage module
Removing and replacing FRUs
Removing the SPC chassis (shuttle)
Installing the SPC chassis (shuttle)
Removing the midplane
Installing the midplane
Removing a midplane-to-fan cable
Installing a midplane-to-fan cable
Removing an air damper
Installing an air damper
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
IBM BladeCenter Airborne Contaminant Filter
PDF file
Introduction
IBM Statement of Limited Warranty Z125-4753-09 08/2006
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Product recycling and disposal
Installing
Removing the bezel
Installing the Airborne Contaminant Filter assembly
Removing
Removing the Airborne Contaminant Filter assembly
Installing the bezel
Replacing a filter
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Management module
Advanced management module
PDF files
Installing
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Using the Web interface
The BladeCenter management module
Related documentation
Notices and statements in this document
Using the management-module web interface
Connecting to the management module
Management-module connection overview
Hardware requirements
Software requirements
Cabling the management module
Networked connection
Direct connection
Connecting to the management module for the first time
IPv6 addressing for initial connection
Starting the management-module web interface
Configuring the management module
Configuring the management module for remote access
Configuring the management-module Ethernet port
Using the configuration wizard
Configuring a blade server management network
Communicating with the IBM Systems Director software
Advanced features
Network and security configuration
Configuring SNMP
Configuring SMTP
Configuring LDAP
Secure web server and secure LDAP
Configuring security
SSL certificate overview
SSL server certificate management
Generating a self-signed certificate
Generating a certificate signing request
Enabling SSL for the secure web server
SSL client certificate management
SSL client trusted certificate management
Enabling SSL for the LDAP client
Configuring the Secure Shell (SSH) server
Generating a Secure Shell host key
Enabling the Secure Shell server
Assigning an SSH public key
Using the Secure Shell server
Enabling SMASH
Using SMASH
Enabling Syslog
Configuring Linux TFTP server
Configuring Wake on LAN
Verifying the Wake on LAN configuration
Linux-specific configuration
Using the configuration file
Backing up your management-module configuration
Backing up an advanced management module configuration
Restoring and modifying your management-module configuration
Restoring a management-module configuration
Restoring an advanced management-module configuration
Using the remote console feature
Using the remote disk feature
Mounting a disk drive or image
Unmounting a disk drive or disk image
Using management channel auto-discovery
Enabling management channel auto-discovery
Viewing management channel auto-discovery status
IBM Service Advisor
Configuring Service Advisor
Using Service Advisor
Connectivity security for Service Advisor
Configuring an I/O module
NEBS mode support
Air filter management for BladeCenter HT and BladeCenter T units
Fouled-filter detection
Passive air filter reminder
Management-module web interface overview
Web interface pages and user roles
Management-module web interface options
Monitors
System Status
BladeCenter unit detailed component status
Event Log
LEDs
BladeCenter unit LEDs
BladeCenter T and BladeCenter HT alarm management
Power Management
Detailed power information
Hardware VPD
Firmware VPD
Remote Chassis
Blade Tasks
Power/Restart
Remote Control
Firmware Update
Firmware Multi-flash
Configuration
Advanced Configuration
Serial Over LAN
Open Fabric Manager
I/O Module Tasks
Admin/Power/Restart
Configuration
Firmware Update
Storage Tasks
MM Control
General Settings
Login Profiles
Alerts
Serial Port
Port Assignments
Network Interfaces
Network Protocols
Chassis Internal Network
Security
File Management
Firmware Update
Configuration Mgmt
Restart MM
License Manager
Service Tools
AMM Service Data
Blade Service Data
AMM Status
Service Advisor
Scalable Complex
Configuration
Troubleshooting
Common Problems
Using the command-line interface
Introduction
Before you begin
Accessibility features for the BladeCenter management module
Using the command-line interface
Command-line interface guidelines
Selecting the command target
Commands and user authority
Cabling the management module
Networked connection
Direct connection
Serial connection
Starting the command-line interface
IPv6 addressing for initial connection
Telnet connection
Serial connection
Secure Shell (SSH) connection
Using the Secure Shell server
Using SMASH
SSH CLI exit codes
BladeCenter unit configuration
Configuring the management module
Starting an SOL session
Ending an SOL session
Command reference
Alphabetic command list
Command list by function
Command syntax
accseccfg command
advfailover command
airfilter command (BladeCenter S only)
alarm command (BladeCenter T and HT only)
alertcfg command
alertentries command
autoftp command
baydata command
bofm command
boot command
bootmode command
bootseq command
buildidcfg command
chconfig command
chlog command
chmanual command
cin command
cinstatus command
clear command
clearlog command
clock command
config command
console command
dhcpinfo command
displaylog command
displaysd command
dns command
env (environment) command
ethoverusb command
eventinfo command
events command
exit command
feature command
files command
fuelg command
groups command
health command
help command
history command
identify (location LED) command
ifconfig command
info (configuration information) command
iocomp command
kvm (keyboard, video, mouse) command
ldapcfg command
led command
list (system physical configuration) command
mcad command
modactlog command
monalerts command
mt (media tray) command
nat command
ntp (network time protocol) command
ping command
pmpolicy command
portcfg command
ports command
power command
rdoc command
read command
remotechassis command
reset command
scale command
sddump command
sdemail command
security command
service command
shutdown command
slp command
smtp command
snmp command
sol (serial over LAN) command
sshcfg command
sslcfg command
syslog command
tcpcmdmode command
telnetcfg (Telnet configuration) command
temps command
trespass command
uicfg command
update (update firmware) command
uplink (management module failover) command
users command
volts command
write command
zonecfg command
Error messages
Common errors
accseccfg command errors
advfailover command errors
alarm command errors
alertcfg command errors
alertentries command errors
autoftp command errors
baydata command errors
bofm command errors
boot command errors
bootmode command errors
bootseq command errors
buildidcfg command errors
chconfig command errors
chlog command errors
chmanual command errors
cin command errors
clear command errors
clearlog command errors
clock command errors
config command errors
console command errors
dhcpinfo command errors
displaylog command errors
displaysd command errors
dns command errors
env command errors
ethoverusb command errors
eventinfo command errors
events command errors
exit command errors
feature command errors
files command errors
fuelg command errors
groups command errors
health command errors
help command errors
history command errors
identify command errors
ifconfig command errors
info command errors
iocomp command errors
kvm command errors
ldapcfg command errors
led command errors
list command errors
mcad command errors
modactlog command errors
monalerts command errors
monalertsleg command errors
mt command errors
nat command errors
ntp command errors
ping command errors
pmpolicy command errors
portcfg command errors
ports command errors
power command errors
rdoc command errors
read command errors
remotechassis command errors
reset command errors
scale command errors
sddump command errors
sdemail command errors
security command errors
service command errors
shutdown command errors
slp command errors
smtp command errors
snmp command errors
sol command errors
sshcfg command errors
sslcfg command errors
syslog command errors
tcpcmdmode command errors
telnetcfg command errors
temps command errors
thres command errors
trespass command errors
uicfg command errors
update command errors
uplink command errors
users command errors
volts command errors
write command errors
zonecfg command errors
Messages
Introduction
The advanced management module
The BC T and BC HT advanced management module
Terminology
Abbreviations
IBM BladeCenter Service Advisor
Troubleshooting BladeCenter issues
Troubleshooting power issues
Troubleshooting blade server processors throttling
Troubleshooting thermal issues
Troubleshooting SAS RAID controller module issues
Diagnostic tools
Light path diagnostic LEDs
Light path diagnostic LEDs - BladeCenter T and BladeCenter HT chassis
LEDs for remote chassis
Advanced management module event messages
The system status summary
The event log
E-mail notification
SNMP traps
Syslog
IBM Director
Service bulletins
IBM Dynamic System Analysis (DSA)
Fields displayed for a message
IPMI blade server event messages
Special messages
Getting help and technical assistance
Before you call
Hardware service and support
Software service and support
Additional resources
Related documentation
IBM websites
I2C buses in a BladeCenter chassis
BladeCenter E and BladeCenter T
BladeCenter H
BladeCenter HT
BladeCenter S
Messages listing
0x00000014
0x00000067
0x0000006B
0x0000006F
0x00000071
0x00000072
0x00000073
0x00000077
0x0000007A
0x00000081
0x00010022
0x00014033
0x00014034
0x00014035
0x00014045
0x00014046
0x00014047
0x0001404A
0x0001404B
0x0001404C
0x0001404D
0x0001404E
0x00014053
0x00014054
0x00014055
0x00014056
0x00014060
0x00014061
0x00015011
0x00015012
0x00015013
0x00015014
0x00015030
0x00015040
0x00015050
0x00015060
0x00015100
0x00015101
0x00015102
0x00015103
0x00015104
0x00015105
0x00015106
0x00015401
0x00015402
0x00015403
0x00015404
0x00015405
0x00015406
0x00015407
0x00015408
0x00015409
0x0001540A
0x0001540B
0x0001540C
0x0001540D
0x0001540E
0x00015500
0x00015501
0x00015503
0x00015504
0x00015505
0x00015506
0x00015600
0x00015700
0x00015800
0x00015801
0x00015802
0x00015803
0x00015804
0x00015805
0x00015806
0x00015807
0x00015808
0x00015809
0x0001580A
0x0001580B
0x00015900
0x00015901
0x00015902
0x00015903
0x00015904
0x00015905
0x00015906
0x00015907
0x00015908
0x00015909
0x0001590A
0x00015A01
0x00015A02
0x00015A03
0x00015A04
0x00015A05
0x00015A06
0x00016001
0x0001600A
0x0001600B
0x0001600D
0x0001600E
0x0001600F
0x00016010
0x00016011
0x00016012
0x00016013
0x00016014
0x00016015
0x00016016
0x00016017
0x00016018
0x00016019
0x0001601A
0x0001601B
0x00016020
0x00016021
0x00016022
0x00016023
0x00016024
0x00016025
0x00016026
0x00016027
0x00016028
0x00016029
0x0001602A
0x0001602B
0x0001602C
0x0001602D
0x0001602E
0x0001602F
0x00016030
0x00016031
0x00016032
0x00016033
0x00016034
0x00016035
0x00016036
0x00016037
0x00016038
0x00016039
0x0001603A
0x0001603B
0x0001603C
0x0001603D
0x0001603F
0x00016040
0x00016044
0x00016048
0x00016049
0x0001604A
0x0001604B
0x0001604C
0x0001604D
0x0001604E
0x0001604F
0x00016050
0x00016051
0x00016053
0x00016054
0x00016055
0x00016057
0x00016058
0x00016059
0x0001605B
0x0001605C
0x0001605E
0x0001605F
0x00016060
0x00016061
0x00016068
0x00016069
0x0001606A
0x0001606B
0x0001606C
0x0001606E
0x0001606F
0x00016070
0x00016071
0x00016072
0x00016073
0x00016074
0x00016075
0x00016076
0x00016077
0x00016078
0x00016079
0x0001607A
0x0001607B
0x0001607C
0x0001607D
0x0001607E
0x0001607F
0x00016080
0x00016081
0x00016082
0x00016083
0x00016084
0x00016085
0x00016086
0x00016087
0x00016088
0x00016089
0x0001608A
0x0001608B
0x0001608C
0x0001608D
0x0001608E
0x00016090
0x00016091
0x00016092
0x00016093
0x00016094
0x00016095
0x00016096
0x00016097
0x00016098
0x00016099
0x0001609A
0x0001609B
0x0001609C
0x0001609D
0x0001609E
0x0001609F
0x000160A0
0x000160A1
0x000160A2
0x000160A3
0x000160A4
0x000160A5
0x000160A6
0x000160A7
0x000160A8
0x000160A9
0x000160AA
0x000160AB
0x000160AC
0x00016100
0x00016101
0x00016102
0x00016103
0x00016104
0x00016105
0x00016201
0x00016202
0x00016203
0x00016204
0x00016205
0x00016206
0x00016207
0x00016208
0x00016209
0x0001620A
0x0001620B
0x0001620C
0x0001620D
0x0001620E
0x00016301
0x00016302
0x00016303
0x00016304
0x00016305
0x00016306
0x00016307
0x00016308
0x00016309
0x0001630A
0x0001630B
0x0001630C
0x0001630D
0x0001630E
0x00016310
0x00016311
0x00016400
0x00016401
0x00016402
0x00016500
0x00016700
0x00016702
0x00016704
0x00016705
0x00016706
0x00016800
0x00016801
0x00016802
0x00016803
0x00017001
0x00017002
0x00017003
0x00017004
0x00017100
0x00017101
0x00017102
0x00017103
0x00017104
0x00017105
0x00017106
0x00017107
0x00017108
0x00017109
0x0001710A
0x0001710B
0x0001710C
0x0001710D
0x0001710E
0x0001710F
0x00017111
0x00017112
0x00017113
0x00017114
0x00017115
0x00017116
0x00017117
0x00017118
0x00017119
0x0001711A
0x0001711B
0x0001711C
0x0001711D
0x00018001
0x0001C482
0x0001C500
0x0001C800
0x0001D400
0x0001D502
0x0001D800
0x00020000
0x00020001
0x00020002
0x00020003
0x00020004
0x00020005
0x00020006
0x00020007
0x00020008
0x00020009
0x0002000A
0x0002000B
0x0002000C
0x0002000D
0x0002000E
0x0002000F
0x00020010
0x00020011
0x00020012
0x00020013
0x00020014
0x00020015
0x00020016
0x00020017
0x00020018
0x00020019
0x0002001A
0x0002001B
0x0002001C
0x0002001D
0x0002001E
0x0002001F
0x00020020
0x00020021
0x00020022
0x00020023
0x00020024
0x00020025
0x00020026
0x00020027
0x00020028
0x00020029
0x0002002A
0x0002002B
0x0002002C
0x0002002D
0x0002002E
0x0002002F
0x00020030
0x00020031
0x00020032
0x00020033
0x00020034
0x00020035
0x00020036
0x00022001
0x00022002
0x00022003
0x00022004
0x00022005
0x00022006
0x00022007
0x00022008
0x00022009
0x0002200A
0x0002200B
0x00022011
0x00022012
0x00022015
0x00022016
0x00022017
0x00022018
0x00022019
0x0002201B
0x0002201C
0x0002201D
0x0002201E
0x00022049
0x0002204A
0x00022052
0x00022053
0x00022054
0x00022055
0x00022058
0x00022059
0x0002205A
0x00026801
0x00026802
0x00026803
0x00026804
0x00026805
0x00026806
0x00026807
0x00026808
0x00026809
0x0002680A
0x00026A01
0x00026A02
0x00026A03
0x00026A04
0x00028000
0x00028001
0x00029400
0x00029402
0x00029401
0x00036801
0x00036002
0x00036003
0x00036004
0x00036005
0x00036006
0x000A2001
0x000A2002
0x000A2003
0x000A2004
0x000A6000
0x000A6001
0x000A6002
0x000A6003
0x000A6004
0x000A6005
0x000A6006
0x000A6007
0x000A6008
0x000A6009
0x000A600A
0x000A7001
0x000A7002
0x000A7003
0x000A7004
0x000A7005
0x000A7006
0x000A7801
0x000A7802
0x000A7803
0x000A7804
0x000A8001
0x000A8002
0x000A8003
0x000A8004
0x000A8005
0x000A8006
0x000A9001
0x000A9002
0x000A9003
0x000A9004
0x000A9005
0x000A9006
0x000A9007
0x000A9008
0x000A9009
0x000A900A
0x000A9101
0x000A9102
0x000A9103
0x000A9104
0x000AA020
0x000B6001
0x000B6002
0x000B6003
0x000B6004
0x000B6005
0x000B6006
0x000FF1BA
0x00101000
0x00101007
0x00104201
0x00104202
0x00104203
0x00104204
0x00104205
0x00104206
0x0011C501
0x0011C881
0x0011C901
0x0011D801
0x00120000
0x00200000
0x00216000
0x00216002
0x00216004
0x00216005
0x00216010
0x00216011
0x00216012
0x00216018
0x0021601C
0x0021603E
0x00217000
0x00217001
0x00217002
0x00217003
0x00217004
0x00217005
0x00222000
0x00282001
0x00282002
0x00282005
0x00284001
0x00284002
0x04000000
0x04000080
0x04000300
0x04000381
0x04000382
0x04000383
0x04000384
0x04000385
0x04000386
0x04000387
0x04000388
0x04000389
0x0400038A
0x0400038B
0x0400038C
0x0400038D
0x0400038E
0x04018000
0x0401E000
0x04110000
0x04110001
0x04200201
0x04200202
0x04200203
0x04200204
0x04204001
0x04204002
0x04204003
0x04204004
0x04204005
0x04204006
0x04204007
0x04204008
0x04210001
0x0421C081
0x0421C082
0x0421D081
0x0421D082
0x0421D083
0x0421D084
0x0421C481
0x0421C482
0x0421C483
0x0421C484
0x0421D401
0x0421D402
0x0421D501
0x0421D502
0x0421D503
0x0421D504
0x04300201
0x04300202
0x04300203
0x04300204
0x04306201
0x04306202
0x04306203
0x04306204
0x04306205
0x04306206
0x04306207
0x04306208
0x04401501
0x04401502
0x04401801
0x04401802
0x04428000
0x04428001
0x04428002
0x04428003
0x04428004
0x05200000
0x06000000
0x06000201
0x06000202
0x06000301
0x06000302
0x06002001
0x06002002
0x06002003
0x06002004
0x06016000
0x06018000
0x0601A000
0x06026080
0x06035500
0x0603550A
0x06035800
0x06035801
0x06037500
0x06037503
0x06037800
0x06037801
0x0621C481
0x0621D481
0x06500000
0x06800000
0x06802000
0x06800001
0x06800002
0x06800003
0x06800004
0x06800005
0x0681C482
0x0681E000
0x0681E001
0x0681E002
0x0681E003
0x0681E004
0x0681E005
0x06A02001
0x06A02002
0x06A03001
0x06A03002
0x06A16001
0x06A16002
0x06A17001
0x06A17002
0x06A1E001
0x06A1E002
0x06A2E001
0x06A2E002
0x08001400
0x08001401
0x08001800
0x08001801
0x08006001
0x08006002
0x0800A401
0x0800A402
0x0800B401
0x0800C401
0x0800D401
0x0800E401
0x0800F401
0x08016080
0x08028001
0x08028002
0x08028003
0x08028004
0x08028081
0x08028082
0x08028083
0x08028084
0x08028481
0x08028482
0x08028483
0x08028484
0x08031480
0x08031481
0x08031880
0x08031881
0x08033480
0x08033481
0x08033880
0x08033881
0x08035500
0x08035800
0x08039480
0x08039880
0x0803D500
0x0803D501
0x0803D800
0x0803D801
0x08041400
0x08041800
0x0807B400
0x0807B401
0x0807B800
0x0807B801
0x08080001
0x08100080
0x08200001
0x08200002
0x08200003
0x08200004
0x08216001
0x08216002
0x08216003
0x08216004
0x0821A001
0x0821A002
0x0821A003
0x0821A004
0x0821C001
0x0821C002
0x0821C003
0x0821C004
0x0821C080
0x0821C081
0x0821C082
0x0821C083
0x0821C084
0x0821E001
0x0821E002
0x0821E003
0x0821E004
0x08236001
0x08236002
0x08236003
0x08236004
0x08236481
0x08236482
0x08236483
0x08236484
0x08236801
0x08236802
0x08236803
0x08236804
0x08238001
0x08238002
0x08238003
0x08238004
0x08238481
0x08238482
0x08238483
0x08238484
0x08238801
0x08238802
0x08238803
0x08238804
0x08240001
0x08240002
0x08240003
0x08240004
0x09025000
0x0A000000
0x0A000280
0x0A000281
0x0A000282
0x0A000283
0x0A000284
0x0A000285
0x0A000286
0x0A000287
0x0A000288
0x0A000289
0x0A00028A
0x0A00028B
0x0A00028C
0x0A00028D
0x0A00028E
0x0A00028F
0x0A000290
0x0A000400
0x0A000401
0x0A000402
0x0A000403
0x0A000404
0x0A000405
0x0A000406
0x0A000407
0x0A000408
0x0A000409
0x0A00040A
0x0A00040B
0x0A00040C
0x0A00040D
0x0A00040E
0x0A00040F
0x0A000410
0x0A000580
0x0A000581
0x0A000582
0x0A000583
0x0A000584
0x0A000585
0x0A000586
0x0A000587
0x0A000588
0x0A000589
0x0A00058A
0x0A00058B
0x0A00058C
0x0A00058D
0x0A00058E
0x0A00058F
0x0A000590
0x0A002001
0x0A002002
0x0A002003
0x0A002004
0x0A002005
0x0A002006
0x0A002007
0x0A002008
0x0A002009
0x0A00200A
0x0A003001
0x0A003002
0x0A003003
0x0A003004
0x0A003005
0x0A003006
0x0A003007
0x0A003008
0x0A003009
0x0A00300A
0x0A00AC02
0x0A00BC02
0x0A027000
0x0A027100
0x0A02CC00
0x0A02CC01
0x0A02CC02
0x0A02DC00
0x0A02DC01
0x0A02DC02
0x0A030C00
0x0A030C01
0x0A030C02
0x0A031C00
0x0A031C01
0x0A031C02
0x0A034C00
0x0A034C02
0x0A035C00
0x0A035C02
0x0A036C00
0x0A036C01
0x0A036C02
0x0A037C00
0x0A037C01
0x0A037C02
0x0A03CC00
0x0A03DC00
0x0A040C00
0x0A040C02
0x0A041C00
0x0A041C02
0x0A07AC00
0x0A07AC02
0x0A07BC00
0x0A07BC02
0x0B026001
0x0B026002
0x0B026003
0x0B026004
0x0B026005
0x0B026006
0x0B026007
0x0B026008
0x0B026009
0x0B02600A
0x0D000281
0x0D000282
0x0D01E000
0x0E002001
0x0E002002
0x0E002003
0x0E002004
0x0E002005
0x0E002006
0x0E002007
0x0E002008
0x0E002009
0x0E00200A
0x0E00200B
0x0E00200C
0x0E00200D
0x0E00200E
0x0E004001
0x0E004002
0x0E004003
0x0E004004
0x0E004005
0x0E004006
0x0E004007
0x0E004008
0x0E004009
0x0E00400A
0x0E00400B
0x0E00400C
0x0E00400D
0x0E00400E
0x0E006001
0x0E006002
0x0E006003
0x0E006004
0x0E006005
0x0E006006
0x0E006007
0x0E006008
0x0E006009
0x0E00600A
0x0E00600B
0x0E00600C
0x0E00600D
0x0E00600E
0x0E008001
0x0E008002
0x0E008003
0x0E008004
0x0E008005
0x0E008006
0x0E008007
0x0E008008
0x0E008009
0x0E00800A
0x0E00800B
0x0E00800C
0x0E00800D
0x0E00800E
0x0E00A001
0x0E00A002
0x0E00A003
0x0E00A004
0x0E00A005
0x0E00A006
0x0E00A007
0x0E00A008
0x0E00A009
0x0E00A00A
0x0E00A00B
0x0E00A00C
0x0E00A00D
0x0E00A00E
0x0E00B001
0x0E00B002
0x0E00B003
0x0E00B004
0x0E00B005
0x0E00B006
0x0E00B007
0x0E00B008
0x0E00B009
0x0E00B00A
0x0E00C001
0x0E00C002
0x0E00C003
0x0E00C004
0x0E00C005
0x0E00C006
0x0E00C007
0x0E00C008
0x0E00C009
0x0E00C00A
0x0E00C00B
0x0E00C00C
0x0E00C00D
0x0E00C00E
0x0E00C28F
0x0E00D001
0x0E00D002
0x0E00D281
0x0E00D282
0x0E00D381
0x0E00D382
0x0E010001
0x0E010002
0x0E010003
0x0E010004
0x0E010005
0x0E010006
0x0E010007
0x0E010008
0x0E010009
0x0E01000A
0x0E01000B
0x0E01000C
0x0E01000D
0x0E01000E
0x0E012041
0x0E012042
0x0E012047
0x0E200001
0x0E200002
0x0E200003
0x0E200004
0x0E200005
0x0E200006
0x0E200007
0x0E200008
0x0E200009
0x0E20000A
0x0E20000B
0x0E20000C
0x0E20000D
0x0E20000E
0x0E418802
0x0E830402
0x0E830802
0x0E832402
0x0E832802
0x0E834402
0x0E834802
0x0E836402
0x0E836802
0x0E83C402
0x0E83C802
0x0E840402
0x0E840802
0x0E850402
0x0E850802
0x0E860402
0x0E860802
0x0E87A402
0x0E87A802
0x0EA00001
0x0EA00002
0x0EA00003
0x0EA00004
0x0EA00005
0x0EA00006
0x0EA00007
0x0EA00008
0x0EA00009
0x0EA0000A
0x0EA01001
0x0EA01002
0x0EA01003
0x0EA01004
0x0EA01005
0x0EA01006
0x0EA01007
0x0EA01008
0x0EA01009
0x0EA0100A
0x0EA02001
0x0EA02002
0x0EA02003
0x0EA02004
0x0EA02005
0x0EA02006
0x0EA02007
0x0EA02008
0x0EA02009
0x0EA0200A
0x0EA04001
0x0EA04002
0x0EA04003
0x0EA04004
0x0EA04005
0x0EA04006
0x0EA04007
0x0EA04008
0x0EA04009
0x0EA0400A
0x0EA05001
0x0EA05002
0x0EA05003
0x0EA05004
0x0EA05005
0x0EA05006
0x0EA05007
0x0EA05008
0x0EA05009
0x0EA0500A
0x0EA06001
0x0EA06002
0x0EA06003
0x0EA06004
0x0EA06005
0x0EA06006
0x0EA06007
0x0EA06008
0x0EA06009
0x0EA0600A
0x0EA08001
0x0EA08002
0x0EA08003
0x0EA08004
0x0EA08005
0x0EA08006
0x0EA08007
0x0EA08008
0x0EA08009
0x0EA0800A
0x0EA0A001
0x0EA0A002
0x0EA0A003
0x0EA0A004
0x0EA0A005
0x0EA0A006
0x0EA0A007
0x0EA0A008
0x0EA0A009
0x0EA0A00A
0x0EA0B001
0x0EA0B002
0x0EA0B003
0x0EA0B004
0x0EA0B005
0x0EA0B006
0x0EA0B007
0x0EA0B008
0x0EA0B009
0x0EA0B00A
0x0EA0C001
0x0EA0C002
0x0EA0C003
0x0EA0C004
0x0EA0C005
0x0EA0C006
0x0EA0C007
0x0EA0C008
0x0EA0C009
0x0EA0C00A
0x0EA0C101
0x0EA0C102
0x0EA0C103
0x0EA0C104
0x0EA0C105
0x0EA0C106
0x0EA0C107
0x0EA0C108
0x0EA0C109
0x0EA0C10A
0x0EA0D001
0x0EA0D002
0x0EA0D003
0x0EA0D004
0x0EA0D005
0x0EA0D006
0x0EA0D007
0x0EA0D008
0x0EA0D009
0x0EA0D00A
0x0EA0D201
0x0EA0D202
0x0EA0D203
0x0EA0D204
0x0EA0D205
0x0EA0D206
0x0EA0D207
0x0EA0D208
0x0EA0D209
0x0EA0D20A
0x0EA0D301
0x0EA0D302
0x0EA0D303
0x0EA0D304
0x0EA0D305
0x0EA0D306
0x0EA0D307
0x0EA0D308
0x0EA0D309
0x0EA0D30A
0x0EA0D401
0x0EA0D402
0x0EA0D403
0x0EA0D404
0x0EA0D405
0x0EA0D406
0x0EA0D407
0x0EA0D408
0x0EA0D409
0x0EA0D40A
0x0EA0D501
0x0EA0D502
0x0EA0D503
0x0EA0D504
0x0EA0D505
0x0EA0D506
0x0EA0D507
0x0EA0D508
0x0EA0D509
0x0EA0D50A
0x0EA0D601
0x0EA0D602
0x0EA0D603
0x0EA0D604
0x0EA0D605
0x0EA0D606
0x0EA0D607
0x0EA0D608
0x0EA0D609
0x0EA0D60A
0x0EA0D701
0x0EA0D702
0x0EA0D703
0x0EA0D704
0x0EA0D705
0x0EA0D706
0x0EA0D707
0x0EA0D708
0x0EA0D709
0x0EA0D70A
0x0EA0D801
0x0EA0D802
0x0EA0D803
0x0EA0D804
0x0EA0D805
0x0EA0D806
0x0EA0D807
0x0EA0D808
0x0EA0D809
0x0EA0D80A
0x0EA0D901
0x0EA0D902
0x0EA0D903
0x0EA0D904
0x0EA0D905
0x0EA0D906
0x0EA0D907
0x0EA0D908
0x0EA0D909
0x0EA0D90A
0x0EA0DB01
0x0EA0DB02
0x0EA0DB03
0x0EA0DB04
0x0EA0DB05
0x0EA0DB06
0x0EA0DB07
0x0EA0DB08
0x0EA0DB09
0x0EA0DB0A
0x0EA0DC01
0x0EA0DC02
0x0EA0DC03
0x0EA0DC04
0x0EA0DC05
0x0EA0DC06
0x0EA0DC07
0x0EA0DC08
0x0EA0DC09
0x0EA0DC0A
0x0EA0E001
0x0EA0E002
0x0EA0E003
0x0EA0E004
0x0EA0E005
0x0EA0E006
0x0EA0E007
0x0EA0E008
0x0EA0E009
0x0EA0E00A
0x0EA0E101
0x0EA0E102
0x0EA0E103
0x0EA0E104
0x0EA0E105
0x0EA0E106
0x0EA0E107
0x0EA0E108
0x0EA0E109
0x0EA0E10A
0x0EA0E201
0x0EA0E202
0x0EA0E203
0x0EA0E204
0x0EA0E205
0x0EA0E206
0x0EA0E207
0x0EA0E208
0x0EA0E209
0x0EA0E20A
0x0EA0E301
0x0EA0E401
0x0EA0E501
0x0EA0E601
0x0EA0E701
0x0EA0E702
0x0EA0E703
0x0EA0E704
0x0EA0E705
0x0EA0E706
0x0EA0E707
0x0EA0E708
0x0EA0E709
0x0EA0E70A
0x0EA0E801
0x0EA0E901
0x0EA0EA01
0x0EA0EA02
0x0EA0EA03
0x0EA0EA04
0x0EA0EA05
0x0EA0EA06
0x0EA0EA07
0x0EA0EA08
0x0EA0EA09
0x0EA0EA0A
0x0EA0EB01
0x0EA0EB02
0x0EA0EB03
0x0EA0EB04
0x0EA0EB05
0x0EA0EB06
0x0EA0EB07
0x0EA0EB08
0x0EA0EB09
0x0EA0EB0A
0x0EA0EC01
0x0EA0EC02
0x0EA0EC03
0x0EA0EC04
0x0EA0EC05
0x0EA0EC06
0x0EA0EC07
0x0EA0EC08
0x0EA0EC09
0x0EA0EC0A
0x0EA0ED01
0x0EA0ED02
0x0EA0ED03
0x0EA0ED04
0x0EA0ED05
0x0EA0ED06
0x0EA0ED07
0x0EA0ED08
0x0EA0ED09
0x0EA0ED0A
0x0EA0EE01
0x0EA0EE02
0x0EA0EE03
0x0EA0EE04
0x0EA0EE05
0x0EA0EE06
0x0EA0EE07
0x0EA0EE08
0x0EA0EE09
0x0EA0EE0A
0x0EA0F001
0x0EA0F002
0x0EA0F003
0x0EA0F004
0x0EA0F005
0x0EA0F006
0x0EA0F007
0x0EA0F008
0x0EA0F009
0x0EA0F00A
0x0EA0F101
0x0EA0F102
0x0EA0F103
0x0EA0F104
0x0EA0F105
0x0EA0F106
0x0EA0F107
0x0EA0F108
0x0EA0F109
0x0EA0F10A
0x0EA0F201
0x0EA0F202
0x0EA0F203
0x0EA0F204
0x0EA0F205
0x0EA0F206
0x0EA0F207
0x0EA0F208
0x0EA0F209
0x0EA0F20A
0x0EA0F301
0x0EA0F302
0x0EA0F303
0x0EA0F304
0x0EA0F305
0x0EA0F306
0x0EA0F307
0x0EA0F308
0x0EA0F309
0x0EA0F30A
0x0EA0F401
0x0EA0F402
0x0EA0F403
0x0EA0F404
0x0EA0F405
0x0EA0F406
0x0EA0F407
0x0EA0F408
0x0EA0F409
0x0EA0F40A
0x0EA0F501
0x0EA0F502
0x0EA0F503
0x0EA0F504
0x0EA0F505
0x0EA0F506
0x0EA0F507
0x0EA0F508
0x0EA0F509
0x0EA0F50A
0x0EA0F601
0x0EA0F602
0x0EA0F603
0x0EA0F604
0x0EA0F605
0x0EA0F606
0x0EA0F607
0x0EA0F608
0x0EA0F609
0x0EA0F60A
0x0EA0F701
0x0EA0F702
0x0EA0F703
0x0EA0F704
0x0EA0F705
0x0EA0F706
0x0EA0F707
0x0EA0F708
0x0EA0F709
0x0EA0F70A
0x0EA0F801
0x0EA0F802
0x0EA0F803
0x0EA0F804
0x0EA0F805
0x0EA0F806
0x0EA0F807
0x0EA0F808
0x0EA0F809
0x0EA0F80A
0x0EA0F901
0x0EA0F902
0x0EA0F903
0x0EA0F904
0x0EA0F905
0x0EA0F906
0x0EA0F907
0x0EA0F908
0x0EA0F909
0x0EA0F90A
0x0EA0FA01
0x0EA0FA02
0x0EA0FA03
0x0EA0FA04
0x0EA0FA05
0x0EA0FA06
0x0EA0FA07
0x0EA0FA08
0x0EA0FA09
0x0EA0FA0A
0x0EA0FB01
0x0EA0FB02
0x0EA0FB03
0x0EA0FB04
0x0EA0FB05
0x0EA0FB06
0x0EA0FB07
0x0EA0FB08
0x0EA0FB09
0x0EA0FB0A
0x0EA0FC01
0x0EA0FC02
0x0EA0FC03
0x0EA0FC04
0x0EA0FC05
0x0EA0FC06
0x0EA0FC07
0x0EA0FC08
0x0EA0FC09
0x0EA0FC0A
0x0EA0FD01
0x0EA0FD02
0x0EA0FD03
0x0EA0FD04
0x0EA0FD05
0x0EA0FD06
0x0EA0FD07
0x0EA0FD08
0x0EA0FD09
0x0EA0FD0A
0x0EA0FE01
0x0EA0FE02
0x0EA0FE03
0x0EA0FE04
0x0EA0FE05
0x0EA0FE06
0x0EA0FE07
0x0EA0FE08
0x0EA0FE09
0x0EA0FE0A
0x0EA0FF01
0x0EA0FF02
0x0EA0FF03
0x0EA0FF04
0x0EA0FF05
0x0EA0FF06
0x0EA0FF07
0x0EA0FF08
0x0EA0FF09
0x0EA0FF0A
0x0EA12001
0x0EA12002
0x0EA12003
0x0EA12004
0x0EA12005
0x0EA12006
0x0EA12007
0x0EA12008
0x0EA12009
0x0EA1200A
0x0EA14001
0x0EA14002
0x0EA14003
0x0EA14004
0x0EA14005
0x0EA14006
0x0EA14007
0x0EA14008
0x0EA14009
0x0EA1400A
0x0EA15001
0x0EA15002
0x0EA15003
0x0EA15004
0x0EA15005
0x0EA15006
0x0EA15007
0x0EA15008
0x0EA15009
0x0EA1500A
0x0EA16001
0x0EA16002
0x0EA1A401
0x0EA1A402
0x0EA1A403
0x0EA1A404
0x0EA1A405
0x0EA1A406
0x0EA1A407
0x0EA1A408
0x0EA1A409
0x0EA1A40A
0x0EA1C401
0x0EA1C402
0x0EA1C403
0x0EA1C404
0x0EA1C405
0x0EA1C406
0x0EA1C407
0x0EA1C408
0x0EA1C409
0x0EA1C40A
0x0EA1D401
0x0EA1D402
0x0EA1D403
0x0EA1D404
0x0EA1D405
0x0EA1D406
0x0EA1D407
0x0EA1D408
0x0EA1D409
0x0EA1D40A
0x0EC00001
0x0EC00002
0x0EE00000
0x0EE18000
0x0F00A001
0x0F00A002
0x0F00A003
0x0F00A004
0x0F00A005
0x0F00A006
0x0F00A007
0x0F00A008
0x0F00A009
0x0F00A00A
0x0F00A00B
0x0F00A00C
0x0F00A00D
0x0F00A00E
0x0F00B001
0x0F00B002
0x0F00B003
0x0F00B004
0x0F00B005
0x0F00B006
0x0F00B007
0x0F00B008
0x0F00B009
0x0F00B00A
0x0F00B00B
0x0F00B00C
0x0F00B00D
0x0F00B00E
0x0F00C001
0x0F00C002
0x0F00C003
0x0F00C004
0x0F00C005
0x0F00C006
0x0F00C007
0x0F00C008
0x0F00C009
0x0F00C00A
0x0F00C00B
0x0F00C00C
0x0F00C00D
0x0F00C00E
0x0F00D001
0x0F00D002
0x0F00D003
0x0F00D004
0x0F00D005
0x0F00D006
0x0F00D007
0x0F00D008
0x0F00D009
0x0F00D00A
0x0F00D00B
0x0F00D00C
0x0F00D00D
0x0F00D00E
0x0F00E001
0x0F00E002
0x0F00E003
0x0F00E004
0x0F00E005
0x0F00E006
0x0F00E007
0x0F00E008
0x0F00E009
0x0F00E00A
0x0F00E00B
0x0F00E00C
0x0F00E00D
0x0F00E00E
0x0F00F001
0x0F00F002
0x0F00F003
0x0F00F004
0x0F00F005
0x0F00F006
0x0F00F007
0x0F00F008
0x0F00F009
0x0F00F00A
0x0F00F00B
0x0F00F00C
0x0F00F00D
0x0F00F00E
0x0F010001
0x0F010002
0x0F010003
0x0F010004
0x0F010005
0x0F010006
0x0F010007
0x0F010008
0x0F010009
0x0F01000A
0x0F01000B
0x0F01000C
0x0F01000D
0x0F01000E
0x0F010101
0x0F010102
0x0F010103
0x0F010104
0x0F010105
0x0F010106
0x0F010107
0x0F010108
0x0F010109
0x0F01010A
0x0F01010B
0x0F01010C
0x0F01010D
0x0F01010E
0x10016000
0x1C000001
0x1C000002
0x1C000003
0x1C000004
0x1E00D001
0x1E00D002
0x1E00D003
0x1E00D004
0x1E00D005
0x1E00D006
0x1E00D007
0x1E00D008
0x1E00D009
0x1E00D00A
0x1E00D00B
0x1E00D00C
0x1E00D00D
0x1E00D00E
0x1E00E001
0x1E00E002
0x1E00E003
0x1E00E004
0x1E00E005
0x1E00E006
0x1E00E007
0x1E00E008
0x1E00E009
0x1E00E00A
0x1E00E00B
0x1E00E00C
0x1E00E00D
0x1E00E00E
0x1E00F001
0x1E00F002
0x1E00F003
0x1E00F004
0x1E00F005
0x1E00F006
0x1E00F007
0x1E00F008
0x1E00F009
0x1E00F00A
0x1E00F00B
0x1E00F00C
0x1E00F00D
0x1E00F00E
0x1E00F00F
0x1E010012
0x40000010
0x40000011
0x40000012
0x40000013
0x40000014
0x40000015
0x40000016
0x40000020
0x40000022
0x40000030
0x40001001
0x40001002
0x40001003
0x40001004
0x40001005
0x40001007
0x40001008
0x4000100A
0x40001006
0x40001009
0x40001020
0x40001021
0x40001022
0x40001023
0x40001024
0x40001025
0x40001026
0x40001027
0x40015070
0x40015080
0x40015090
0x4001711E
0x40110001
0x40110002
0x40217006
0x40217007
0x40217008
0x40324001
0x40324002
0x40324003
0x40324004
0x40324005
0x40324006
0x40324007
0x40324008
0x40324009
0x4032400A
0x40324101
0x40324102
0x40324103
0x40324104
0x40324105
0x40324106
0x40324107
0x40324108
0x40324109
0x4032410A
0x40324201
0x40324202
0x40324203
0x40324204
0x40324205
0x40324206
0x40324207
0x40324208
0x40324209
0x4032420A
0x40324301
0x40324302
0x40324303
0x40324304
0x40324305
0x40324306
0x40324307
0x40324308
0x40324309
0x4032430A
0x40324401
0x40324402
0x40324403
0x40324404
0x40324405
0x40324406
0x40324407
0x40324408
0x40324409
0x4032440A
0x40324501
0x40324502
0x40324503
0x40324504
0x40324505
0x40324506
0x40324507
0x40324508
0x40324509
0x4032450A
0x40324601
0x40324602
0x40324603
0x40324604
0x40324605
0x40324606
0x40324607
0x40324608
0x40324609
0x4032460A
0x40324701
0x40324702
0x40324703
0x40324704
0x40324705
0x40324706
0x40324707
0x40324708
0x40324709
0x4032470A
0x40324801
0x40324802
0x40324803
0x40324804
0x40324805
0x40324806
0x40324807
0x40324808
0x40324809
0x4032480A
0x40324901
0x40324902
0x40324903
0x40324904
0x40324905
0x40324906
0x40324907
0x40324908
0x40324909
0x4032490A
0x40324A01
0x40324A02
0x40324A03
0x40324A04
0x40324A05
0x40324A06
0x40324A07
0x40324A08
0x40324A09
0x40324A0A
0x40524901
0x40524902
0x40524903
0x40524904
0x40524905
0x40524906
0x40524907
0x40524908
0x40524909
0x4052490A
0x40624901
0x40624902
0x43000101
0x43000102
0x43000103
0x43000104
0x43000105
0x43000106
0x43000108
0x43000109
0x4300010A
0x4300010B
0x4300010C
0x4300010D
0x4300010E
0x43000500
0x48008401
0x48008402
0x4800A400
0x64001000
0x6E000001
0x6F100000
0x6F100001
0x6F200000
0x6F300000
0x6F500000
0x6F600001
0x6F600002
0x6F600101
0x6F600102
0x6F601001
0x6F601002
0x6F601101
0x6F601102
0x6F602001
0x6F602002
0x6F602003
0x6F602004
0x6F602005
0x6F602006
0x6F602007
0x6F602008
0x6F602009
0x6F60200A
0x6F602101
0x6F602102
0x6F602103
0x6F602104
0x6F602105
0x6F602106
0x6F602107
0x6F602108
0x6F602109
0x6F60210A
0x6F603001
0x6F603002
0x6F603003
0x6F603004
0x6F603005
0x6F603006
0x6F603007
0x6F603008
0x6F603009
0x6F60300A
0x6F603101
0x6F603102
0x6F603103
0x6F603104
0x6F603105
0x6F603106
0x6F603107
0x6F603108
0x6F603109
0x6F60310A
0x6F608001
0x6F608002
0x6F609001
0x6F609002
0x6F609101
0x6F609102
0x6F60A001
0x6F60A002
0x6F60A003
0x6F60A101
0x6F60A201
0x6F60A401
0x6F60B001
0x6F60B101
0x6F60C001
0x6F60C002
0x6F60C101
0x6F60C102
0x6F60C201
0x6F60C202
0x6F60D001
0x6F60D002
0x6F60F001
0x6F60F002
0x6F700001
0x6F700002
0x6F700003
0x6F700004
0x6F700005
0x6F800001
0x6F800002
0x6F800101
0x6F800102
0x6F800301
0x6F800302
0x6F800401
0x6F800402
0x6F800501
0x6F800502
0x6F800601
0x6F800602
0x6F801001
0x6F801002
0x6F801003
0x6F801004
0x6F801005
0x6F801006
0x6F801007
0x6F801008
0x6F801009
0x6F80100A
0x6F80100B
0x6F80100C
0x6F801101
0x6F801102
0x6F801103
0x6F801104
0x6F801105
0x6F801106
0x6F801107
0x6F801108
0x6F801109
0x6F80110A
0x6F80110B
0x6F80110C
0x6F801201
0x6F801202
0x6F801203
0x6F801204
0x6F801205
0x6F801206
0x6F801207
0x6F801208
0x6F801209
0x6F80120A
0x6F80120B
0x6F80120C
0x6F801301
0x6F801302
0x6F801303
0x6F801304
0x6F801305
0x6F801306
0x6F801307
0x6F801308
0x6F801309
0x6F80130A
0x6F80130B
0x6F80130C
0x6F801401
0x6F801402
0x6F801403
0x6F801404
0x6F801405
0x6F801406
0x6F801407
0x6F801408
0x6F801409
0x6F80140A
0x6F80140B
0x6F80140C
0x6F801501
0x6F801502
0x6F801503
0x6F801504
0x6F801505
0x6F801506
0x6F801507
0x6F801508
0x6F801509
0x6F80150A
0x6F80150B
0x6F80150C
0x6F801601
0x6F801602
0x6F801603
0x6F801604
0x6F801605
0x6F801606
0x6F801607
0x6F801608
0x6F801609
0x6F80160A
0x6F80160B
0x6F80160C
0x6F801701
0x6F801702
0x6F801703
0x6F801704
0x6F801705
0x6F801706
0x6F801707
0x6F801708
0x6F801709
0x6F80170A
0x6F80170B
0x6F80170C
0x6F802001
0x6F802002
0x6F802101
0x6F802102
0x6F803001
0x6F803002
0x6F900001
0x6F900002
0x6F900003
0x6F900004
0x6F901001
0x6F901002
0x6F901003
0x6F901004
0x6FA00001
0x6FA01001
0x6FA02001
0x800000FF
0x80010000
0x80010200
0x80010400
0x80010700
0x80010701
0x80010702
0x80010002
0x80010900
0x80010901
0x80010902
0x80010202
0x80010B00
0x80010B01
0x80010B02
0x80010402
0x80030100
0x80070000
0x80070100
0x80070200
0x80070300
0x80070500
0x80070600
0x80080000
0x80090000
0x800B0100
0x800B0300
0x800B0400
0x800B0500
0x806F0007
0x806F0009
0x806F000D
0x806F002C
0x806F000F
0x806F0013
0x806F001E
0x806F001F
0x806F011F
0x806F021F
0x806F041F
0x806F0021
0x806F0029
0x806F002B
0x806F0107
0x806F0108
0x806F0109
0x806F010C
0x806F010D
0x806F010F
0x806F0112
0x806F0113
0x806F011B
0x806F0120
0x806F0129
0x806F012B
0x806F0207
0x806F0208
0x806F020D
0x806F020F
0x806F0212
0x806F0229
0x806F030C
0x806F0313
0x806F032B
0x806F0407
0x806F0409
0x806F040C
0x806F0413
0x806F0507
0x806F0509
0x806F050C
0x806F050D
0x806F0513
0x806F0521
0x806F052B
0x806F0607
0x806F0609
0x806F060C
0x806F060D
0x806F0707
0x806F070C
0x806F070D
0x806F0807
0x806F0813
0x806F0A07
0x806F0A13
Setting up Serial over LAN
Introduction
Hardware and firmware requirements
Hardware requirements
Firmware requirements
Checking firmware versions
Starting the BladeCenter management-module Web interface
General configuration
Configuring the global SOL settings for the BladeCenter unit
Configuring the management module
Installing and configuring SSH for SOL
Enabling SOL for blade servers
Updating and configuring the blade server BIOS
Operating system configuration
Linux configuration
Red Hat Enterprise Linux ES 2.1 configuration
SUSE SLES 8.0 configuration
Installing the Ethernet controller device driver for Linux operating systems
Microsoft Windows 2003 Standard Edition configuration
Special component requirements
Configuring the BladeCenter HS22 Type 7870 blade server
Configuring the BladeCenter HS20 Type 8832 and HS20 Type 8843 blade servers
HS20 Type 8832 SOL jumper placement
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the BladeCenter HS40 Type 8839 blade server
Updating the Baseboard Management Controller firmware
Updating and configuring the BIOS
Configuring the BladeCenter JS20 Type 8842 blade server
Updating the open firmware (BIOS)
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the IBM 4-Port Gb Ethernet Switch Module for BladeCenter
Configuring the Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter
Configuring the Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM BladeCenter
Connecting an Intelligent Copper Pass-thru Module
Using SOL
Starting an SOL session
Starting a command-line Telnet connection
Establishing a serial connection
Starting a command-line Secure Shell (SSH) connection
Starting an SOL session from the command-line interface
Ending an SOL session
Monitoring SOL session status
Restarting a blade server through SOL
Mounting and unmounting media for Linux operating systems
Troubleshooting SOL
Management module indicates that blade server does not support SOL
Blade server shows SOL status of Not Ready
SOL session opens and drops
Trouble entering SOL commands or receiving double prompts
Garbage characters in an SOL session
IBM BladeCenter Open Fabric Manager
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
BladeCenter Open Fabric Manager
Requirements
Hardware requirements
Supported software
License information
Accessibility
Documentation and related information
Notices and statements in this document
Overview
Configuration file
Sample configuration file
Mapping of devices to ports
Multi-slot blades and the port offset parameter
Standby AMM
Preparing for BOFM
Upgrading firmware
Setting up boot from SAN
Basic BOFM
AMM Web interface
Installing BOFM
Session and credentials
Configuring
Creating a configuration file automatically
Selecting domains
Avoiding address duplication
Resolving duplicate address errors
Creating a requirements report
Editing the configuration file manually
Applying a new configuration
Viewing the configuration in a local chassis
Retrieving the current configuration
Using Basic BOFM
Initial deployment
Adding a new chassis to the domain
Replacing a blade in the same slot
Swapping addresses between blades
Replacing AMM IP addresses
Replacing the AMM in a single AMM environment
CLI command
Advanced BOFM
Stand-alone version for Windows
Stand-alone version for Linux
Importing BOFM-Advanced upgrade
Using Advanced BOFM
Starting Advanced BOFM
Adding chassis inventory
Managing chassis inventory
Managing blade inventory
Creating or importing an address manager template
Managing an address manager template
Creating a standby blade pool template
Managing a standby blade pool template
Creating a failover monitor
Managing a failover monitor
Troubleshooting
Basic BOFM troubleshooting
Events
BOFM address usage
Configuration failure scenarios
Error messages
Advanced BOFM troubleshooting
Common problems
Problems when you create or apply a standby blade pool
BOFM To IBM Fabric Manager Migration
Steps for BOFM to IBM Fabric Manager (IFM) migration
BOFM Basic to IFM Migration Option 1 – Do Nothing
BOFM Basic to IFM Migration Option 2 – Import CSV File
BOFM Basic to IFM Migration Option 3 – Create Deployment by Harvesting from BladeCenter
BOFM Basic to IFM Migration Option 4 – Start Over
Management module
PDF files
Installing
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Using the Web interface
The BladeCenter management module
Accessibility features for the BladeCenter management module
Related documentation
Notices and statements in this documentation
Using the management-module Web interface
Connecting to the management module
Management-module connection overview
Hardware requirements
Software requirements
Cabling the management module
Networked connection
Direct connection
Connecting to the management module for the first time
Starting the management-module Web interface
Configuring the management module
Configuring the management module for remote access
Configuring the management-module Ethernet ports
Communicating with the IBM Director software
Configuring advanced features
Network and security configuration
Configuring SNMP
Configuring SMTP
Configuring LDAP
Secure Web server and secure LDAP
Configuring the Secure Shell (SSH) server
Configuring Wake on LAN
Verifying the Wake on LAN configuration
Linux-specific configuration
Using the configuration file
Backing up your management-module configuration
Restoring and modifying your management-module configuration
Using the remote disk feature
Mounting a disk drive or disk image
Unmounting a disk drive or disk image
Configuring an I/O module
Management-module Web interface overview
Web interface pages and user roles
Management-module Web interface options
Monitors
System Status
BladeCenter T alarm management
BladeCenter unit detailed component status
Event Log
LEDs
BladeCenter unit LEDs
BladeCenter T alarm management
Fuel Gauge
Detailed power information
Hardware VPD
Firmware VPD
Blade Tasks
Power/Restart
Remote Control
Firmware Update
Configuration
Serial Over LAN
I/O Module Tasks
Admin/Power/Restart
Configuration
Firmware Update
MM Control
General Settings
Login Profiles
Alerts
Port Assignments
Network Interfaces
Network Protocols
Security
Configuration File
Firmware Update
Restore Defaults
Restart MM
Using the command-line interface
Introduction
Before you begin
Accessibility features for the BladeCenter management module
Using the command-line interface
Command-line interface guidelines
Selecting the command target
Commands and user authority
Cabling the management module
Networked connection
Direct connection
Starting the command-line interface
Telnet connection
Secure Shell (SSH) connection
Using the Secure Shell server
BladeCenter unit configuration
Configuring the management module
Starting an SOL session
Ending an SOL session
Command reference
Alphabetic command list
Command list by function
Command syntax
alarm command (BladeCenter T only)
alertentries command
boot command
clear command
clearlog command
clock command
config command
console command
dhcpinfo command
displaylog command
dns command
env (environment) command
exit command
fuelg command
health command
help command
history command
identify (location LED) command
ifconfig command
info (configuration information) command
kvm (keyboard, video, mouse) command
list (system physical configuration) command
mt (media tray) command
power command
reset command
shutdown command
slp command
smtp command
snmp command
sol (serial over LAN) command
tcpcmdmode command
telnetcfg (Telnet configuration) command
update (update firmware) command
uplink (management module failover) command
users command
Error messages
Common errors
alarm command errors
alertentries command errors
boot command errors
clear command errors
clearlog command errors
clock command errors
config command errors
console command errors
dhcpinfo command errors
displaylog command errors
dns command errors
env command errors
exit command errors
fuelg command errors
health command errors
help command errors
history command errors
identify command errors
ifconfig command errors
info command errors
kvm command errors
list command errors
mt command errors
power command errors
reset command errors
shutdown command errors
slp command errors
smtp command errors
snmp command errors
sol command errors
tcpcmdmode command errors
telnetcfg command errors
update command errors
uplink command errors
users command errors
Setting up Serial over LAN
Introduction
Hardware and firmware requirements
Hardware requirements
Firmware requirements
Checking firmware versions
Starting the BladeCenter management-module Web interface
General configuration
Configuring the global SOL settings for the BladeCenter unit
Configuring the management module
Installing and configuring SSH for SOL
Enabling SOL for blade servers
Updating and configuring the blade server BIOS
Operating system configuration
Linux configuration
Red Hat Enterprise Linux ES 2.1 configuration
SUSE SLES 8.0 configuration
Installing the Ethernet controller device driver for Linux operating systems
Microsoft Windows 2003 Standard Edition configuration
Special component requirements
Configuring the BladeCenter HS22 Type 7870 blade server
Configuring the BladeCenter HS20 Type 8832 and HS20 Type 8843 blade servers
HS20 Type 8832 SOL jumper placement
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the BladeCenter HS40 Type 8839 blade server
Updating the Baseboard Management Controller firmware
Updating and configuring the BIOS
Configuring the BladeCenter JS20 Type 8842 blade server
Updating the open firmware (BIOS)
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the IBM 4-Port Gb Ethernet Switch Module for BladeCenter
Configuring the Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter
Configuring the Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM BladeCenter
Connecting an Intelligent Copper Pass-thru Module
Using SOL
Starting an SOL session
Starting a command-line Telnet connection
Establishing a serial connection
Starting a command-line Secure Shell (SSH) connection
Starting an SOL session from the command-line interface
Ending an SOL session
Monitoring SOL session status
Restarting a blade server through SOL
Mounting and unmounting media for Linux operating systems
Troubleshooting SOL
Management module indicates that blade server does not support SOL
Blade server shows SOL status of Not Ready
SOL session opens and drops
Trouble entering SOL commands or receiving double prompts
Garbage characters in an SOL session
Blade servers
HS12 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Safety and environmental notices
Notices and statements
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
IBM Statement of Limited Warranty Z125-4753-09 08/2006
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing options
Removing the blade server from the BladeCenter unit
Opening the blade server cover
Removing an optional expansion unit
Installing a fixed-storage drive
Installing a hot-swap storage drive
Installing a memory module
Installing a concurrent KVM card
I/O expansion cards
Installing an I/O expansion card
Installing a high-speed expansion card
Installing an optional expansion unit
Completing the installation
Closing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Configuration/Setup Utility program
Configuration/Setup Utility menu
Using passwords
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Typical operating-system installation
Installing the operating system without using ServerGuide
Using the PXE boot agent utility program
Firmware updates
Configuring the Gigabit Ethernet controller
Configuring a SAS RAID array
Using the LSI Logic Configuration Utility program
Installing the operating system
Using the ServerGuide Setup and Installation CD to install the operating system
Using RDM to install the operating system
Downloading installation instructions
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools
POST
POST beep codes
Beep code descriptions
No-beep symptoms
Error logs
Viewing the BMC log from the Configuration/Setup Utility program
Viewing the BMC log from the diagnostic programs
BMC error messages
POST error codes
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
BMC self tests
Broadcom Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Microprocessor problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Recovering from a BIOS update failure
Service processor (BMC) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Solving undetermined problems
Removing and replacing blade server components
Parts listing, Types 8014, 8028 and 1916
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 customer replaceable units (CRUs)
Removing the blade server cover
Installing the blade server cover
Removing an optional expansion unit
Installing an optional expansion unit
Removing the bezel assembly
Installing the bezel assembly
Removing a fixed-storage drive
Installing a fixed-storage drive
Removing a hot-swap storage drive
Installing a hot-swap storage drive
Removing a memory module
Installing a memory module
Removing a concurrent KVM card
Installing a concurrent KVM card
Removing an I/O expansion card
Installing an I/O expansion card
Removing a storage interface card
Installing a storage interface card
Removing a high-speed expansion card
Installing a high-speed expansion card
Removing the battery
Installing the battery
Removing and replacing field replaceable units
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS20 Blade Server
Installing
Troubleshooting
Warranty
HS21 Blade Server
Installing
Troubleshooting
Warranty
HS21 XM Blade Server
Installing
Troubleshooting
Warranty
HS22 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety and environmental notices
Notices and statements in this document
Safety
Guidelines for trained technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Opening the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a hot-swap SAS drive
Removing a hot-swap SAS drive
Installing a memory module
Removing a memory module
Installing a USB module
Installing a USB module
I/O expansion cards
Installing a compact-form-factor expansion card
Removing a compact-form-factor expansion card
Installing a CIOv expansion card
Removing a CIOv-form-factor expansion card
Installing a storage interface card
Removing a storage interface card
Completing the installation
Closing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu choices
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Typical operating-system installation
Installing the operating system without using ServerGuide
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controllers
Configuring a SAS RAID array
Using the LSI Logic Configuration Utility program
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
For IPMI Windows Server 2003 R2 based operating systems
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Installing the operating system
Using the ServerGuide Setup and Installation CD to install the operating system
Using RDM to install the operating system
Downloading installation instructions
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools
POST
Error logs
Viewing the IMM log through the Setup utility
Viewing event logs withoug restarting the blade server
IMM error messages
POST error codes
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs in the blade server
Light path diagnostics LEDs
Viewing the light path diagnostics LEDs in the BladeCenter GPU expansion unit
BladeCenter GPU expansion unit light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM self tests
Broadcom Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Recovering from a UEFI update failure
In-band manual recover method
Out-of-band manual recover method
In-band automated boot recovery method
Out-of-band automated boot recovery method
Automated boot recovery (ABR)
Nx boot failure
Service processor (IMM) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing
Parts listing - BladeCenter HS22
Parts listing - BladeCenter GPU expansion unit
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from a BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 CRUs
Removing the blade server cover
Installing the blade server cover
Removing a blade handle
Installing a blade handle
Removing a hot-swap SAS drive
Installing a hot-swap SAS drive
Removing a memory module
Installing a memory module
Removing a USB module
Installing a USB module
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a compact-form-factor expansion card
Removing a storage interface card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a compact-form-factor expansion card
Installing a storage interface card
Removing and replacing Tier 2 CRUs
Removing the bezel assembly
Installing the bezel assembly
Removing the control panel
Installing the control panel
Removing and replacing FRUs
Removing an optional expansion unit
Installing an optional expansion unit
Removing a GPU adapter from an expansion unit
Installing a GPU adapter in an expansion unit
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Removing and replacing consumable parts
Removing the battery
Installing the battery
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS22V Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
Blade server connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Removing the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a SSD storage drive
Removing a SSD storage drive
Installing a memory module
Removing a memory module
Installing a USB Flash key
Removing a USB Flash key
I/O expansion cards
Installing a horizontal-combination-form-factor expansion card
Removing a horizontal-combination-form-factor expansion card
Installing a CIOv-form-factor expansion card
Removing a CIOv-form-factor expansion card
Installing a storage interface card
Removing a storage interface card
Completing the installation
Closing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Installing the operating system
Typical operating-system installation
Using the ServerGuide Setup and Installation CD to install the operating system
Installing the operating system without using ServerGuide
Using RDM to install the operating system
Downloading installation instructions
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controller
Configuring a RAID array
Using the LSI Logic Configuration Utility program
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
For IPMI Windows Server 2003 R2 based operating systems - IBM BladeCenter HS22V
LAN over USB Windows Driver Installation - IBM BladeCenter HS22V
LAN over USB Linux Driver Installation
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools overview
POST
Error logs
Viewing event logs through the Setup utility
Viewing event logs without restarting the blade server
IMM error messages
POST error codes
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM I2C tests
Broadcom Ethernet device tests
CPU stress tests
Memory I2C tests
Optical drive
Storage drive tests
Tape alert flags
Service processor (IMM) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Storage drive tests
Recovering from a UEFI update failure
In-band manual recovery method
Out-of-band manual recovery method
In-band automated boot recovery method
Out-of-band automated boot recovery method
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing, Types 7871 and 1949
Removing and replacing blade server components
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 customer replaceable units (CRUs)
Removing the blade server cover
Closing the blade server cover
Removing an optional expansion unit
Installing an optional expansion unit
Removing the bezel assembly
Installing the bezel assembly
Removing a SSD storage drive
Installing a SSD storage drive
Removing a memory module
Installing a memory module
Removing a USB Flash key
Installing a USB Flash key
Removing the battery
Installing the battery
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a horizontal-combination-form-factor expansion card
Removing a storage interface card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a horizontal-combination-form-factor expansion card
Installing a storage interface card
Removing and replacing Tier 2 customer replaceable units (CRUs)
Removing an SSD storage tray
Installing an SSD storage tray
Removing and replacing field replaceable units
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS23 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety
Guidelines for trained technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Taiwan BSMI RoHS declaration
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Removing the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a hot-swap storage drive
Removing a hot-swap storage drive
Installing a memory module
Removing a memory module
Installing a USB module
Removing a USB module
I/O expansion cards
Installing a compact-form-factor expansion card
Removing a compact-form-factor expansion card
Installing a CIOv expansion card
Removing a CIOv-form-factor expansion card
Installing a 10Gb LOM interposer card
Removing a 10Gb LOM interposer card
Completing the installation
Installing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Installing the operating system
Typical operating-system installation
Using the ServerGuide Setup and Installation CD to install the operating system
Installing the operating system without using ServerGuide
Using RDM to install the operating system
Downloading installation instructions
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controllers
Configuring a RAID array
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Troubleshooting
Diagnostics
Service bulletins
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Diagnostic tools
Event logs
Viewing the IMM log through the Setup utility
Viewing event logs withoug restarting the blade server
POST
POST/UEFI diagnostic codes
IMM error messages
Troubleshooting tables
General problems
Hard disk drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs in the blade server
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM self tests
Emulex Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Recovering from a UEFI update failure
In-band manual recovery method
Out-of-band manual recovery method
In-band automated boot recovery method
Out-of-band automated boot recovery method
Automated boot recovery (ABR)
Nx boot failure
Service processor (IMM) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing
Parts listing, Types 7875 and 1929
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from a BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 CRUs
Removing a hot-swap storage drive
Installing a hot-swap storage drive
Removing a memory module
Installing a memory module
Removing a USB module
Installing a USB module
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a compact-form-factor expansion card
Removing a 10Gb interposer card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a compact-form-factor expansion card
Installing a 10Gb interposer card
Removing the battery
Installing the battery
Removing the control panel
Installing the control panel
Removing a blade handle
Installing a blade handle
Removing and replacing Tier 2 CRUs
Removing an optional expansion unit
Installing an optional expansion unit
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Removing and replacing consumable and structural parts
Removing the blade server cover
Installing the blade server cover
Removing the bezel assembly
Installing the bezel assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS23E Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Removing the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a memory module
Removing a memory module
Installing a USB module
Removing a USB module
I/O expansion cards
Installing a compact-form-factor expansion card
Removing a compact-form-factor expansion card
Installing a CIOv expansion card
Removing a CIOv-form-factor expansion card
Removing a storage interface card
Installing a storage interface card
Removing the control panel
Installing the control panel
Completing the installation
Installing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Installing the operating system
Typical operating-system installation
Using the ServerGuide Setup and Installation CD to install the operating system
Installing the operating system without using ServerGuide
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controllers
Using the LSI Logic Configuration Utility program
Starting the LSI Configuration Utility program
Starting the HII Configuration Application
Creating a RAID array
Creating a software RAID array of hard disk drives
Setting Option ROM Execution Order
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools
POST
Error logs
Viewing the IMM log through the Setup utility
Viewing event logs withoug restarting the blade server
IMM error messages
POST error codes
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM self tests
Broadcom Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Recovering from a UEFI update failure
In-band manual recover method
Out-of-band manual recover method
In_band_automated_recovery
Out_of_band_automated_recovery
Service processor (IMM) error codes
Automated boot recovery (ABR)
Nx boot failure
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Storage drive self tests
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing
Parts listing, Types 8038 and 8039
Consumable and structural Parts
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from a BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing blade server components
Removing the blade server cover
Installing the blade server cover
Removing the bezel assembly
Installing the bezel assembly
Removing a blade handle
Installing a blade handle
Removing the air baffle
Installing the air baffle
Removing and replacing Tier 1 CRUs
Removing the battery
Installing the battery
Removing a hot-swap SAS drive
Installing a hot-swap SAS drive
Removing a memory module
Installing a memory module
Removing a USB module
Installing a USB module
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a compact-form-factor expansion card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a compact-form-factor expansion card
Removing a storage interface card
Installing a storage interface card
Removing the control panel
Installing the control panel
Removing an optional expansion unit
Installing an optional expansion unit
Removing and replacing Tier 2 CRUs
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HX5 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
IBM® Director
Major components
Working with a scalable blade complex
Safety and environmental notices
Notices and statements in this information
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
kh9_r_safety_statements.html
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Scalability indicators
Turning on the blade server
Turning off the blade server
System-board layouts
Connectors - BladeCenter HX5
System-board switches
Connectors - IBM MAX5
LEDs - BladeCenter HX5
LEDs - IBM MAX5
Input/output connectors and devices
Installing Options
Removing a blade server from a BladeCenter chassis
Removing the blade server cover
Disassembling a scalable blade complex
Removing the 2-node scalability card
Removing the IBM MAX5 1-node scalability card
Removing an IBM MAX5
Installing a DIMM - IBM MAX5
Removing a DIMM - IBM MAX5
Installing a SSD expansion card
Removing a SSD expansion card
Installing an SSD
Removing an SSD
Installing a DIMM - BladeCenter HX5
Removing a DIMM - BladeCenter HX5
Installing a hypervisor key
Removing a hypervisor key
Installing I/O expansion cards
Installing a CIOv expansion card
Installing a CFFh expansion card
Removing I/O expansion cards
Removing a CFFh expansion card
Removing a CIOv expansion card
Installing a PCI expansion blade
Removing a PCI expansion blade
Installing a microcessor and heat sink
Installing the 1-node speed burst card
Removing the 1-node speed burst card
Completing the installation
Assembling a scalable blade complex
Installing the scalability tray
Installing the 2-node scalabiity card
Installing an IBM MAX5
Installing the IBM MAX5 1-node scalabiity card
Installing the blade server cover
Installing the blade server in a BladeCenter chassis
Updating the blade server configuration
Configuring the blade server
Partitioning a scalable blade complex
Using the Setup utility
Using the PXE boot agent utility program
Using the Boot Menu program
Using the Advanced Settings Utility (ASU)
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the LSI Logic Configuration Utility program
Updating firmware and device drivers
Updating firmware for blade servers operating as a single partition
Updating firmware for each blade server independently
Recovering from a UEFI update failure
In-band manual recover method
Out-of-band manual recover method
In_band_automated_recovery
Out_of_band_automated_recovery
Installing the operating system
Using the ServerGuide Setup and Installation CD
ServerGuide features
Typical operating-system installation
Installing the operating system without using ServerGuide
Using IBM ServerGuide Scripting Toolkit
Accessing the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Troubleshooting
Start here
Diagnosing a problem
Undocumented problems
Diagnostics
Service bulletins
Checkout procedure
Diagnostic tools
Event logs
Viewing event logs through the Setup utility
Viewing event logs without restarting the blade server
POST error codes
IMM/AMM error codes
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs - BladeCenter HX5 blade server
Light path diagnostics LEDs - IBM MAX5
Dynamic system analysis diagnostic programs and messages
DSA editions
Running the diagnostic programs
Diagnostic text messages
Viewing the test results
Diagnostic messages
Microprocessor test
Memory test
IMM I2C test
Optical drive (CD or DVD) test
Ethernet controller test
Troubleshooting tables
General problems
Chassis problems
Hard disk drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Software problems
Universal Serial Bus (USB) port problems
Solving undetermined problems
Removing and replacing components
Parts listing
Parts listing - BladeCenter HX5 blade server
Parts listing - IBM MAX5
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing a blade server from a BladeCenter chassis
Installing the blade server in a BladeCenter chassis
Disassembling a scalable blade complex
Assembling a scalable blade complex
Removing and replacing Tier 1 CRUs
Removing the blade server cover
Installing the blade server cover
Removing the battery
Installing the battery
Removing and replacing Tier 2 CRUs
Removing the scalability tray
Installing the scalability tray
Removing the 1-node speed burst card
Installing the1-node speed burst card
Removing the 2-node scalability card
Installing the 2-node scalabiity card
Removing an IBM MAX5
Installing an IBM MAX5
Removing the IBM MAX5 1-node scalability card
Installing the IBM MAX5 1-node scalabiity card
Removing a PCI expansion blade
Installing a PCI expansion blade
Removing a SSD expansion card
Installing a SSD expansion card
Removing an SSD
Installing an SSD
Removing a DIMM - BladeCenter HX5
Installing a DIMM - BladeCenter HX5
Removing a DIMM - IBM MAX5
Installing a DIMM - IBM MAX5
Removing a hypervisor key
Installing a hypervisor key
Removing an I/O expansion card
Removing a CFFh expansion card
Removing a CIOv expansion card
Installing an I/O expansion card
Installing a CFFh expansion card
Installing a CIOv expansion card
Removing the control panel
Installing the control panel
Removing and replacing FRUs
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
JS12 Blade Server
JS20 Blade Server
JS21 Blade Server
JS22 Blade Server
JS23 and JS43 Blade Server
LS20 Blade Server
Installing
Troubleshooting
Warranty
LS21 Blade Server
Installing
Troubleshooting
Warranty
LS22 Blade Server
Installing
Troubleshooting
Warranty
LS41 Blade Server
Installing
Troubleshooting
Warranty
LS42 Blade Server
Installing
Troubleshooting
Warranty
PS700 Blade Server
PS701 and PS702 Blade Server
PS703 and PS704 Blade Server
QS21 Blade Server
Installing
Troubleshooting
QS22 Blade Server
Installing
Troubleshooting
Warranty
Special purpose blade devices
IBM WebSphere DataPower Integration Blade XI50B appliance
PDF files
Installing and Using
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Safety
Safety statements
Introduction
Related documentation
The IBM Documentation CD
Hardware and software requirements
Using the Documentation Browser
Notices and statements in this document
Features and specifications
Major components of the blade appliance
Input/output connectors and devices
Power, controls, and indicators
Blade appliance controls and LEDs
Control panel controls and LEDs
Storage drive controls and LEDs
Expansion unit controls and LEDs
Turning on the blade appliance
Turning off the blade appliance
Installing and removing the blade appliance
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Installing the blade appliance
Installing the expansion unit
Installing the blade appliance in a BladeCenter unit
Updating the blade appliance configuration
Removing the blade appliance from the BladeCenter unit
Removing the expansion unit
Setting up the initial firmware configuration
Configuration requirements
Connection requirements
Information requirements
Password for administration account
Operational modes
Initializing the blade appliance
Verifying the configuration with the WebGUI
Completing the configuration
Defining the base configuration manually
Downloading the firmware image
Solving problems
Solving installation problems
Solving operational problems
IBM WebSphere DataPower Integration Blade XI50B unique information
Diagnostic tools overview
Error logs
Working with event logs during system startup
Viewing event logs without restarting the blade appliance
Parts listing,
HC10 Blade Workstation
Installing
Troubleshooting
Warranty
PN41 Deep Packet Inspection Blade
Getting Started
Installing
Troubleshooting
Warranty
Expansion units
BladeCenter Storage and I/O Expansion Blade
BladeCenter Memory and I/O Expansion Blade
BladeCenter PCI I/O Expansion Units
BladeCenter AMD Opteron LS41 Multiprocessor Expansion Unit
BladeCenter AMD LS42 Multiprocessor Expansion Unit
I/O modules
Ethernet switch modules
IBM BladeCenter 1/10 Gb Uplink Ethernet Switch Module
IBM BladeCenter Virtual Fabric 10Gb Switch Module
IBM BladeCenter 10 Gb Uplink Ethernet Switch Module
IBM BladeCenter Layer 2/3 Gigabit Ethernet Switch Module
IBM BladeCenter Layer 2-7 GbE Switch Module
Cisco Catalyst Switch Module 3012 for IBM BladeCenter
Cisco Catalyst Switch Module 3110X for IBM BladeCenter
Cisco Catalyst Switch Module 3110G for IBM BladeCenter
Cisco Systems Gigabit Ethernet Switch Module
Cisco Systems Fiber Intelligent Gigabit Ethernet Switch Module
IBM BladeCenter Server Connectivity Module
Fibre Channel switch modules
Brocade 10- and 20-port SAN Switch Modules for IBM BladeCenter
Cisco 4Gb 10 and 20 port Fibre Channel Switch Module for IBM BladeCenter
McDATA 10- and 20-port 4Gb Fibre Channel Switch Modules for IBM BladeCenter
QLogic 10- and 20-port 4 Gb Switch Modules for IBM BladeCenter
QLogic 10-port 4 Gb SAN Switch Module for IBM BladeCenter
QLogic 20-port 4 Gb SAN Switch Module for IBM BladeCenter
QLogic 20-port 8 Gb SAN Switch Module for IBM BladeCenter
InfiniBand switch modules
Cisco Systems 4X InfiniBand Switch Module for IBM BladeCenter
QLogic InfiniBand Ethernet Bridge Module for IBM BladeCenter
QLogic InfiniBand Fibre Channel Bridge Module for IBM BladeCenter
Pass-thru modules
IBM BladeCenter 10 Gb Ethernet Passthru Module
IBM BladeCenter Copper Pass-thru Module
IBM BladeCenter Optical Pass-thru Module
IBM 4X InfiniBand Pass-thru Module for IBM BladeCenter
IBM Intelligent Copper Pass-Thru Module for IBM BladeCenter
QLogic 4 Gb Intelligent Pass-thru Module for IBM BladeCenter
QLogic 8 Gb Intelligent pass-thru module
Storage I/O modules
IBM BladeCenter SAS Connectivity Module
IBM BladeCenter SAS RAID Controller Module
Expansion cards
Cisco 4X InfiniBand DDR CFF Expansion Card (CFFh)
Cisco InfiniBand HCA Expansion Card
Cisco Topspin InfiniBand HCA Expansion Card
Emulex 4 Gb Fibre Channel Expansion Card (CFFv)
Emulex 4 Gb SFF Fibre Channel Expansion Card
IBM 2/4 Port Ethernet Expansion Card (CFFh)
IBM 4X InfiniBand DDR Expansion Card (CFFh)
IBM BladeCenter Concurrent KVM Feature Card
IBM Ethernet Expansion Card (CIOv)
IBM BladeCenter Fibre Channel Expansion Card and JS20 Fibre Channel Expansion Card
IBM Gigabit Ethernet Expansion Card (CIOv)
IBM BladeCenter SAS Expansion Card (CFFv)
IBM BladeCenter SAS Connectivity Card (CIOv)
IBM BladeCenter SFF Fibre Channel Expansion Card
IBM BladeCenter SFF Gigabit Ethernet Expansion Card
IBM System i5 Integrated xSeries PCI-x iSCSI HBA (copper)
IBM System i5 Integrated xSeries PCI-x iSCSI HBA (fiber)
Intel Gigabit Ethernet Expansion Card
Intel 10Gb 2-port Ethernet Expansion Card (CFFh)
Myrinet Cluster Expansion Card
NetXen 10 Gb 2-Port Ethernet Expansion Card
QLogic 4 Gb Fibre Channel Expansion Card (CIOv)
QLogic 4 Gb SFF Fibre Channel Expansion Card
QLogic 4 Gb Standard Fibre Channel Expansion Card
QLogic 8 Gb Fibre Channel Expansion Card (CIOv)
QLogic Ethernet and 8 Gb Fibre Channel Expansion Card (CFFh)
QLogic iSCSI Expansion Card
Voltaire 4X InfiniBand DDR (CFFh) Expansion Card
What's New
Additional information sources
BladeCenter Security – Best Practices
Racks
IBM 11U Office Enablement Kit
PDF file
Introduction
Safety
Rack safety statements
IBM Statement of Limited Warranty Z125-4753-10 08/2008
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
United Kingdom telecommunications safety requirement
European Union EMC Directive conformance statement
Taiwanese Class A warning statement
Chinese Class A warning statement
Japanese Voluntary Control Council for Interference (FCS) statement
Planning
Physical dimensions and clearances
Installing
Installation considerations
Installation guidelines
System reliability guidelines
Setting up the Office Enablement Kit
Removing the Office Enablement Kit from the pallet
Removing the front door
Installing the stabilizer bracket
Extending the stabilizer bracket
Installing optional devices
Installing an uninterruptible power supply
Installing a System x server
Installing a BladeCenter chassis
Shipping a BladeCenter S chassis
Installing a flat-panel monitor console kit
Installing a blank filler panel
Installing the front door
Installing the rear door
Managing cables
Removing and replacing components
Parts listing
Replacing a door lock
Replacing the hinge bracket and door latch
Replacing casters
Replacing the stabilizer bracket assembly
Getting help and technical assistance
Before you call
Hardware service and support
Software service and support
IBM Taiwan product service
Chassis
BladeCenter E (8677)
Planning
Installing
Troubleshooting
Warranty
Options
BladeCenter T (8720/8730)
Planning
Installing
Troubleshooting
Warranty
Options
BladeCenter HT (8740/8750)
Installing
Troubleshooting
Warranty
Options
BladeCenter H (8852)
Installing
Troubleshooting
Warranty
Options
BladeCenter S (8886/7779)
PDF files
Product overview
Features and specifications
Components
Front view
Disk storage module
Media tray
Battery backup unit
Blade server
Rear view
Advanced management module - BladeCenter S Types 7779 and 8886
Indicators and controls
Input and output connectors
Serial pass-thru module
I/O modules
Power modules
Fan modules
Systems and storage management
IBM Director
Storage Configuration Manager
Safety
Guidelines for servicing electrical equipment
Inspecting for unsafe conditions
Safety statements
IBM Statement of Limited Warranty Z125-4753-10 08/2008
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Learning and tutorials
Introducing the BladeCenter S Type 8886
Configuring your BladeCenter S system
Configuring your BladeCenter S system storage
Managing your BladeCenter S system
Planning
Planning for the physical environment
Dimensions
Weight considerations
Floor space
Rack requirements
IBM NetBAY and non-IBM racks
Noise considerations
Power considerations
Power source requirements
Power consumption guidelines
Power management policies
Power allocation guidelines
Power diagrams
110 VAC
220 VAC
Cooling considerations
Air temperature and humidity
Airflow considerations
Heat output
Prevention of air recirculation
Room cooling
Deployment
Network topology
Deployment of the BladeCenter S system
Hardware for the BladeCenter S system
I/O module bay configuration options
I/O module bay 1 configuration options
I/O module bay 2 configuration options
I/O module bays 3 and 4 configuration options
Deployment tools
IBM Director
Remote Deployment Manager
IBM ServerGuide
Management connection
Deployment of blade servers
Hardware for blade servers
Operating system considerations
Application considerations
Planning for configuration
Configuration tools
BladeCenter Open Fabric Manager
Storage Configuration Manager
Keyboard, video, and mouse
Planning for advanced management module configuration
General settings
User profile settings
Alert settings
Serial port
Port settings
Ethernet network settings
Network protocols settings
Security settings
Ethernet switch module configuration planning
SAS connectivity module
User-defined configurations
Predefined configurations
Predefined storage configuration 02
Predefined storage configuration 03
Predefined storage configuration 04
Predefined storage configuration 05
Predefined storage configuration 06
Predefined storage configuration 07
Predefined storage configuration 08
Predefined storage configuration 09
SAS RAID controller module
Defining storage pools
Defining volumes
Zone for SAS RAID controller modules
Replacing SAS connectivity modules with SAS RAID controller modules
Planning worksheets
Installation planning worksheets
Blade server and workstation blade installation worksheet
BladeCenter S Types 7779 and 8886 installation worksheet
Rack installation worksheet
Cabling worksheet
Power worksheet
Configuration planning worksheets
Advanced management module configuration worksheet
SAS connectivity module configuration worksheet
SAS RAID controller module
Installing
Preparing to install your BladeCenter S system
Verifying ship group contents
Obtaining firmware and device drivers
Obtaining configuration, systems management, and storage management software
Setting up your BladeCenter S system
Removing components
Installing the BladeCenter S chassis in a rack
Rack-mounting template
Installing components
Installing the battery backup unit
Installing a disk storage module
Installing a blade server
Installing a serial pass-thru module
Installing an advanced management module
Installing a power module
Installing a fan module
Installing an I/O module
Cabling the BladeCenter S chassis
Connecting the BladeCenter S chassis to power
Disconnecting power from the BladeCenter unit
Installing IBM Director Server (optional)
Configuring
Configuring I/O modules
Configuring blade servers
Selecting shared BladeCenter resources
Troubleshooting
Service bulletins
Diagnostic tools
Light path diagnostic LEDs
System LED panel
Module LEDs
Event log
Watchdog timeout messages
I-error messages
I2C errors
Updating firmware
Isolating component failures
Symptoms by component
Advanced management module
Can ping the advanced management module but cannot access it
Cannot connect to the advanced management module
Cannot log in to the advanced management module
BIST errors
Blade servers
Blade server cannot communicate with external network
Blade server will not power on
I-error messages displayed for an Intel-based blade server
I-error messages displayed for an AMD-based blade server
Kernel mode displayed for blade server
No LEDs appear
No VPD available from advanced management module
Power LED continually flashes rapidly
Service processor communication (SP COMM) errors displayed for a blade server
Service processor communication error displayed for multiple blade servers
Watchdog timeout messages displayed for a blade server
Watchdog timeout messages displayed for multiple blade servers
Fan modules
Fan module running at full speed
Fan module is stopped
Fan modules continually cycle to full speed
I/O modules
I/O module will not power on
LEDs are not lit for an I/O module
Cannot communicate with external ports on I/O module
Blade server cannot communicate through CPM ports
Keyboard, mouse, or pointing devices
Keyboard or mouse device not working
Keyboard or mouse device not working after KVM ownership change
Media tray
Blade server cannot access the media tray
Multiple blade servers cannot access the media tray
Blade servers cannot communicate with the media tray
Monitor or video
Local and remote video not working
Remote video displays but local video does not
Local video displays but remote video does not
Power modules
BladeCenter S chassis has no power
The ac and dc LEDs are not lit for multiple power supplies
The dc LED is not lit but ac LED is lit
Fault LED is lit
Serial over LAN
Blade server does not support SoL (as reported in the advanced management module)
Blade server SoL status enabled but not ready (in management module)
SoL session will not stay up
Trouble entering commands or receiving double prompts
Characters received or typed are incorrect
Storage module
Hard disk drives not available to blade servers
Removing and replacing BladeCenter components
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Parts listing
Front view
Rear view
Power cords - C14 power module
Power cords - C20 power module
Removing and replacing CRUs
Removing a bezel
Installing a bezel
Removing the media tray
Installing the media tray
Removing the DVD drive
Installing the DVD drive
Removing the battery backup unit
Installing the battery backup unit
Removing an advanced management module
Installing an advanced management module
Removing a blade server
Installing a blade server
Removing a fan module
Installing a fan module
Removing an I/O module
Installing an I/O module
Removing a power module
Installing a power module
Removing a serial pass-thru module
Installing a serial pass-thru module
Removing a disk storage module
Installing a disk storage module
Removing and replacing FRUs
Removing the SPC chassis (shuttle)
Installing the SPC chassis (shuttle)
Removing the midplane
Installing the midplane
Removing a midplane-to-fan cable
Installing a midplane-to-fan cable
Removing an air damper
Installing an air damper
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
IBM BladeCenter Airborne Contaminant Filter
PDF file
Introduction
IBM Statement of Limited Warranty Z125-4753-09 08/2006
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Product recycling and disposal
Installing
Removing the bezel
Installing the Airborne Contaminant Filter assembly
Removing
Removing the Airborne Contaminant Filter assembly
Installing the bezel
Replacing a filter
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Management module
Advanced management module
PDF files
Installing
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Using the Web interface
The BladeCenter management module
Related documentation
Notices and statements in this document
Using the management-module web interface
Connecting to the management module
Management-module connection overview
Hardware requirements
Software requirements
Cabling the management module
Networked connection
Direct connection
Connecting to the management module for the first time
IPv6 addressing for initial connection
Starting the management-module web interface
Configuring the management module
Configuring the management module for remote access
Configuring the management-module Ethernet port
Using the configuration wizard
Configuring a blade server management network
Communicating with the IBM Systems Director software
Advanced features
Network and security configuration
Configuring SNMP
Configuring SMTP
Configuring LDAP
Secure web server and secure LDAP
Configuring security
SSL certificate overview
SSL server certificate management
Generating a self-signed certificate
Generating a certificate signing request
Enabling SSL for the secure web server
SSL client certificate management
SSL client trusted certificate management
Enabling SSL for the LDAP client
Configuring the Secure Shell (SSH) server
Generating a Secure Shell host key
Enabling the Secure Shell server
Assigning an SSH public key
Using the Secure Shell server
Enabling SMASH
Using SMASH
Enabling Syslog
Configuring Linux TFTP server
Configuring Wake on LAN
Verifying the Wake on LAN configuration
Linux-specific configuration
Using the configuration file
Backing up your management-module configuration
Backing up an advanced management module configuration
Restoring and modifying your management-module configuration
Restoring a management-module configuration
Restoring an advanced management-module configuration
Using the remote console feature
Using the remote disk feature
Mounting a disk drive or image
Unmounting a disk drive or disk image
Using management channel auto-discovery
Enabling management channel auto-discovery
Viewing management channel auto-discovery status
IBM Service Advisor
Configuring Service Advisor
Using Service Advisor
Connectivity security for Service Advisor
Configuring an I/O module
NEBS mode support
Air filter management for BladeCenter HT and BladeCenter T units
Fouled-filter detection
Passive air filter reminder
Management-module web interface overview
Web interface pages and user roles
Management-module web interface options
Monitors
System Status
BladeCenter unit detailed component status
Event Log
LEDs
BladeCenter unit LEDs
BladeCenter T and BladeCenter HT alarm management
Power Management
Detailed power information
Hardware VPD
Firmware VPD
Remote Chassis
Blade Tasks
Power/Restart
Remote Control
Firmware Update
Firmware Multi-flash
Configuration
Advanced Configuration
Serial Over LAN
Open Fabric Manager
I/O Module Tasks
Admin/Power/Restart
Configuration
Firmware Update
Storage Tasks
MM Control
General Settings
Login Profiles
Alerts
Serial Port
Port Assignments
Network Interfaces
Network Protocols
Chassis Internal Network
Security
File Management
Firmware Update
Configuration Mgmt
Restart MM
License Manager
Service Tools
AMM Service Data
Blade Service Data
AMM Status
Service Advisor
Scalable Complex
Configuration
Troubleshooting
Common Problems
Using the command-line interface
Introduction
Before you begin
Accessibility features for the BladeCenter management module
Using the command-line interface
Command-line interface guidelines
Selecting the command target
Commands and user authority
Cabling the management module
Networked connection
Direct connection
Serial connection
Starting the command-line interface
IPv6 addressing for initial connection
Telnet connection
Serial connection
Secure Shell (SSH) connection
Using the Secure Shell server
Using SMASH
SSH CLI exit codes
BladeCenter unit configuration
Configuring the management module
Starting an SOL session
Ending an SOL session
Command reference
Alphabetic command list
Command list by function
Command syntax
accseccfg command
advfailover command
airfilter command (BladeCenter S only)
alarm command (BladeCenter T and HT only)
alertcfg command
alertentries command
autoftp command
baydata command
bofm command
boot command
bootmode command
bootseq command
buildidcfg command
chconfig command
chlog command
chmanual command
cin command
cinstatus command
clear command
clearlog command
clock command
config command
console command
dhcpinfo command
displaylog command
displaysd command
dns command
env (environment) command
ethoverusb command
eventinfo command
events command
exit command
feature command
files command
fuelg command
groups command
health command
help command
history command
identify (location LED) command
ifconfig command
info (configuration information) command
iocomp command
kvm (keyboard, video, mouse) command
ldapcfg command
led command
list (system physical configuration) command
mcad command
modactlog command
monalerts command
mt (media tray) command
nat command
ntp (network time protocol) command
ping command
pmpolicy command
portcfg command
ports command
power command
rdoc command
read command
remotechassis command
reset command
scale command
sddump command
sdemail command
security command
service command
shutdown command
slp command
smtp command
snmp command
sol (serial over LAN) command
sshcfg command
sslcfg command
syslog command
tcpcmdmode command
telnetcfg (Telnet configuration) command
temps command
trespass command
uicfg command
update (update firmware) command
uplink (management module failover) command
users command
volts command
write command
zonecfg command
Error messages
Common errors
accseccfg command errors
advfailover command errors
alarm command errors
alertcfg command errors
alertentries command errors
autoftp command errors
baydata command errors
bofm command errors
boot command errors
bootmode command errors
bootseq command errors
buildidcfg command errors
chconfig command errors
chlog command errors
chmanual command errors
cin command errors
clear command errors
clearlog command errors
clock command errors
config command errors
console command errors
dhcpinfo command errors
displaylog command errors
displaysd command errors
dns command errors
env command errors
ethoverusb command errors
eventinfo command errors
events command errors
exit command errors
feature command errors
files command errors
fuelg command errors
groups command errors
health command errors
help command errors
history command errors
identify command errors
ifconfig command errors
info command errors
iocomp command errors
kvm command errors
ldapcfg command errors
led command errors
list command errors
mcad command errors
modactlog command errors
monalerts command errors
monalertsleg command errors
mt command errors
nat command errors
ntp command errors
ping command errors
pmpolicy command errors
portcfg command errors
ports command errors
power command errors
rdoc command errors
read command errors
remotechassis command errors
reset command errors
scale command errors
sddump command errors
sdemail command errors
security command errors
service command errors
shutdown command errors
slp command errors
smtp command errors
snmp command errors
sol command errors
sshcfg command errors
sslcfg command errors
syslog command errors
tcpcmdmode command errors
telnetcfg command errors
temps command errors
thres command errors
trespass command errors
uicfg command errors
update command errors
uplink command errors
users command errors
volts command errors
write command errors
zonecfg command errors
Messages
Introduction
The advanced management module
The BC T and BC HT advanced management module
Terminology
Abbreviations
IBM BladeCenter Service Advisor
Troubleshooting BladeCenter issues
Troubleshooting power issues
Troubleshooting blade server processors throttling
Troubleshooting thermal issues
Troubleshooting SAS RAID controller module issues
Diagnostic tools
Light path diagnostic LEDs
Light path diagnostic LEDs - BladeCenter T and BladeCenter HT chassis
LEDs for remote chassis
Advanced management module event messages
The system status summary
The event log
E-mail notification
SNMP traps
Syslog
IBM Director
Service bulletins
IBM Dynamic System Analysis (DSA)
Fields displayed for a message
IPMI blade server event messages
Special messages
Getting help and technical assistance
Before you call
Hardware service and support
Software service and support
Additional resources
Related documentation
IBM websites
I2C buses in a BladeCenter chassis
BladeCenter E and BladeCenter T
BladeCenter H
BladeCenter HT
BladeCenter S
Messages listing
0x00000014
0x00000067
0x0000006B
0x0000006F
0x00000071
0x00000072
0x00000073
0x00000077
0x0000007A
0x00000081
0x00010022
0x00014033
0x00014034
0x00014035
0x00014045
0x00014046
0x00014047
0x0001404A
0x0001404B
0x0001404C
0x0001404D
0x0001404E
0x00014053
0x00014054
0x00014055
0x00014056
0x00014060
0x00014061
0x00015011
0x00015012
0x00015013
0x00015014
0x00015030
0x00015040
0x00015050
0x00015060
0x00015100
0x00015101
0x00015102
0x00015103
0x00015104
0x00015105
0x00015106
0x00015401
0x00015402
0x00015403
0x00015404
0x00015405
0x00015406
0x00015407
0x00015408
0x00015409
0x0001540A
0x0001540B
0x0001540C
0x0001540D
0x0001540E
0x00015500
0x00015501
0x00015503
0x00015504
0x00015505
0x00015506
0x00015600
0x00015700
0x00015800
0x00015801
0x00015802
0x00015803
0x00015804
0x00015805
0x00015806
0x00015807
0x00015808
0x00015809
0x0001580A
0x0001580B
0x00015900
0x00015901
0x00015902
0x00015903
0x00015904
0x00015905
0x00015906
0x00015907
0x00015908
0x00015909
0x0001590A
0x00015A01
0x00015A02
0x00015A03
0x00015A04
0x00015A05
0x00015A06
0x00016001
0x0001600A
0x0001600B
0x0001600D
0x0001600E
0x0001600F
0x00016010
0x00016011
0x00016012
0x00016013
0x00016014
0x00016015
0x00016016
0x00016017
0x00016018
0x00016019
0x0001601A
0x0001601B
0x00016020
0x00016021
0x00016022
0x00016023
0x00016024
0x00016025
0x00016026
0x00016027
0x00016028
0x00016029
0x0001602A
0x0001602B
0x0001602C
0x0001602D
0x0001602E
0x0001602F
0x00016030
0x00016031
0x00016032
0x00016033
0x00016034
0x00016035
0x00016036
0x00016037
0x00016038
0x00016039
0x0001603A
0x0001603B
0x0001603C
0x0001603D
0x0001603F
0x00016040
0x00016044
0x00016048
0x00016049
0x0001604A
0x0001604B
0x0001604C
0x0001604D
0x0001604E
0x0001604F
0x00016050
0x00016051
0x00016053
0x00016054
0x00016055
0x00016057
0x00016058
0x00016059
0x0001605B
0x0001605C
0x0001605E
0x0001605F
0x00016060
0x00016061
0x00016068
0x00016069
0x0001606A
0x0001606B
0x0001606C
0x0001606E
0x0001606F
0x00016070
0x00016071
0x00016072
0x00016073
0x00016074
0x00016075
0x00016076
0x00016077
0x00016078
0x00016079
0x0001607A
0x0001607B
0x0001607C
0x0001607D
0x0001607E
0x0001607F
0x00016080
0x00016081
0x00016082
0x00016083
0x00016084
0x00016085
0x00016086
0x00016087
0x00016088
0x00016089
0x0001608A
0x0001608B
0x0001608C
0x0001608D
0x0001608E
0x00016090
0x00016091
0x00016092
0x00016093
0x00016094
0x00016095
0x00016096
0x00016097
0x00016098
0x00016099
0x0001609A
0x0001609B
0x0001609C
0x0001609D
0x0001609E
0x0001609F
0x000160A0
0x000160A1
0x000160A2
0x000160A3
0x000160A4
0x000160A5
0x000160A6
0x000160A7
0x000160A8
0x000160A9
0x000160AA
0x000160AB
0x000160AC
0x00016100
0x00016101
0x00016102
0x00016103
0x00016104
0x00016105
0x00016201
0x00016202
0x00016203
0x00016204
0x00016205
0x00016206
0x00016207
0x00016208
0x00016209
0x0001620A
0x0001620B
0x0001620C
0x0001620D
0x0001620E
0x00016301
0x00016302
0x00016303
0x00016304
0x00016305
0x00016306
0x00016307
0x00016308
0x00016309
0x0001630A
0x0001630B
0x0001630C
0x0001630D
0x0001630E
0x00016310
0x00016311
0x00016400
0x00016401
0x00016402
0x00016500
0x00016700
0x00016702
0x00016704
0x00016705
0x00016706
0x00016800
0x00016801
0x00016802
0x00016803
0x00017001
0x00017002
0x00017003
0x00017004
0x00017100
0x00017101
0x00017102
0x00017103
0x00017104
0x00017105
0x00017106
0x00017107
0x00017108
0x00017109
0x0001710A
0x0001710B
0x0001710C
0x0001710D
0x0001710E
0x0001710F
0x00017111
0x00017112
0x00017113
0x00017114
0x00017115
0x00017116
0x00017117
0x00017118
0x00017119
0x0001711A
0x0001711B
0x0001711C
0x0001711D
0x00018001
0x0001C482
0x0001C500
0x0001C800
0x0001D400
0x0001D502
0x0001D800
0x00020000
0x00020001
0x00020002
0x00020003
0x00020004
0x00020005
0x00020006
0x00020007
0x00020008
0x00020009
0x0002000A
0x0002000B
0x0002000C
0x0002000D
0x0002000E
0x0002000F
0x00020010
0x00020011
0x00020012
0x00020013
0x00020014
0x00020015
0x00020016
0x00020017
0x00020018
0x00020019
0x0002001A
0x0002001B
0x0002001C
0x0002001D
0x0002001E
0x0002001F
0x00020020
0x00020021
0x00020022
0x00020023
0x00020024
0x00020025
0x00020026
0x00020027
0x00020028
0x00020029
0x0002002A
0x0002002B
0x0002002C
0x0002002D
0x0002002E
0x0002002F
0x00020030
0x00020031
0x00020032
0x00020033
0x00020034
0x00020035
0x00020036
0x00022001
0x00022002
0x00022003
0x00022004
0x00022005
0x00022006
0x00022007
0x00022008
0x00022009
0x0002200A
0x0002200B
0x00022011
0x00022012
0x00022015
0x00022016
0x00022017
0x00022018
0x00022019
0x0002201B
0x0002201C
0x0002201D
0x0002201E
0x00022049
0x0002204A
0x00022052
0x00022053
0x00022054
0x00022055
0x00022058
0x00022059
0x0002205A
0x00026801
0x00026802
0x00026803
0x00026804
0x00026805
0x00026806
0x00026807
0x00026808
0x00026809
0x0002680A
0x00026A01
0x00026A02
0x00026A03
0x00026A04
0x00028000
0x00028001
0x00029400
0x00029402
0x00029401
0x00036801
0x00036002
0x00036003
0x00036004
0x00036005
0x00036006
0x000A2001
0x000A2002
0x000A2003
0x000A2004
0x000A6000
0x000A6001
0x000A6002
0x000A6003
0x000A6004
0x000A6005
0x000A6006
0x000A6007
0x000A6008
0x000A6009
0x000A600A
0x000A7001
0x000A7002
0x000A7003
0x000A7004
0x000A7005
0x000A7006
0x000A7801
0x000A7802
0x000A7803
0x000A7804
0x000A8001
0x000A8002
0x000A8003
0x000A8004
0x000A8005
0x000A8006
0x000A9001
0x000A9002
0x000A9003
0x000A9004
0x000A9005
0x000A9006
0x000A9007
0x000A9008
0x000A9009
0x000A900A
0x000A9101
0x000A9102
0x000A9103
0x000A9104
0x000AA020
0x000B6001
0x000B6002
0x000B6003
0x000B6004
0x000B6005
0x000B6006
0x000FF1BA
0x00101000
0x00101007
0x00104201
0x00104202
0x00104203
0x00104204
0x00104205
0x00104206
0x0011C501
0x0011C881
0x0011C901
0x0011D801
0x00120000
0x00200000
0x00216000
0x00216002
0x00216004
0x00216005
0x00216010
0x00216011
0x00216012
0x00216018
0x0021601C
0x0021603E
0x00217000
0x00217001
0x00217002
0x00217003
0x00217004
0x00217005
0x00222000
0x00282001
0x00282002
0x00282005
0x00284001
0x00284002
0x04000000
0x04000080
0x04000300
0x04000381
0x04000382
0x04000383
0x04000384
0x04000385
0x04000386
0x04000387
0x04000388
0x04000389
0x0400038A
0x0400038B
0x0400038C
0x0400038D
0x0400038E
0x04018000
0x0401E000
0x04110000
0x04110001
0x04200201
0x04200202
0x04200203
0x04200204
0x04204001
0x04204002
0x04204003
0x04204004
0x04204005
0x04204006
0x04204007
0x04204008
0x04210001
0x0421C081
0x0421C082
0x0421D081
0x0421D082
0x0421D083
0x0421D084
0x0421C481
0x0421C482
0x0421C483
0x0421C484
0x0421D401
0x0421D402
0x0421D501
0x0421D502
0x0421D503
0x0421D504
0x04300201
0x04300202
0x04300203
0x04300204
0x04306201
0x04306202
0x04306203
0x04306204
0x04306205
0x04306206
0x04306207
0x04306208
0x04401501
0x04401502
0x04401801
0x04401802
0x04428000
0x04428001
0x04428002
0x04428003
0x04428004
0x05200000
0x06000000
0x06000201
0x06000202
0x06000301
0x06000302
0x06002001
0x06002002
0x06002003
0x06002004
0x06016000
0x06018000
0x0601A000
0x06026080
0x06035500
0x0603550A
0x06035800
0x06035801
0x06037500
0x06037503
0x06037800
0x06037801
0x0621C481
0x0621D481
0x06500000
0x06800000
0x06802000
0x06800001
0x06800002
0x06800003
0x06800004
0x06800005
0x0681C482
0x0681E000
0x0681E001
0x0681E002
0x0681E003
0x0681E004
0x0681E005
0x06A02001
0x06A02002
0x06A03001
0x06A03002
0x06A16001
0x06A16002
0x06A17001
0x06A17002
0x06A1E001
0x06A1E002
0x06A2E001
0x06A2E002
0x08001400
0x08001401
0x08001800
0x08001801
0x08006001
0x08006002
0x0800A401
0x0800A402
0x0800B401
0x0800C401
0x0800D401
0x0800E401
0x0800F401
0x08016080
0x08028001
0x08028002
0x08028003
0x08028004
0x08028081
0x08028082
0x08028083
0x08028084
0x08028481
0x08028482
0x08028483
0x08028484
0x08031480
0x08031481
0x08031880
0x08031881
0x08033480
0x08033481
0x08033880
0x08033881
0x08035500
0x08035800
0x08039480
0x08039880
0x0803D500
0x0803D501
0x0803D800
0x0803D801
0x08041400
0x08041800
0x0807B400
0x0807B401
0x0807B800
0x0807B801
0x08080001
0x08100080
0x08200001
0x08200002
0x08200003
0x08200004
0x08216001
0x08216002
0x08216003
0x08216004
0x0821A001
0x0821A002
0x0821A003
0x0821A004
0x0821C001
0x0821C002
0x0821C003
0x0821C004
0x0821C080
0x0821C081
0x0821C082
0x0821C083
0x0821C084
0x0821E001
0x0821E002
0x0821E003
0x0821E004
0x08236001
0x08236002
0x08236003
0x08236004
0x08236481
0x08236482
0x08236483
0x08236484
0x08236801
0x08236802
0x08236803
0x08236804
0x08238001
0x08238002
0x08238003
0x08238004
0x08238481
0x08238482
0x08238483
0x08238484
0x08238801
0x08238802
0x08238803
0x08238804
0x08240001
0x08240002
0x08240003
0x08240004
0x09025000
0x0A000000
0x0A000280
0x0A000281
0x0A000282
0x0A000283
0x0A000284
0x0A000285
0x0A000286
0x0A000287
0x0A000288
0x0A000289
0x0A00028A
0x0A00028B
0x0A00028C
0x0A00028D
0x0A00028E
0x0A00028F
0x0A000290
0x0A000400
0x0A000401
0x0A000402
0x0A000403
0x0A000404
0x0A000405
0x0A000406
0x0A000407
0x0A000408
0x0A000409
0x0A00040A
0x0A00040B
0x0A00040C
0x0A00040D
0x0A00040E
0x0A00040F
0x0A000410
0x0A000580
0x0A000581
0x0A000582
0x0A000583
0x0A000584
0x0A000585
0x0A000586
0x0A000587
0x0A000588
0x0A000589
0x0A00058A
0x0A00058B
0x0A00058C
0x0A00058D
0x0A00058E
0x0A00058F
0x0A000590
0x0A002001
0x0A002002
0x0A002003
0x0A002004
0x0A002005
0x0A002006
0x0A002007
0x0A002008
0x0A002009
0x0A00200A
0x0A003001
0x0A003002
0x0A003003
0x0A003004
0x0A003005
0x0A003006
0x0A003007
0x0A003008
0x0A003009
0x0A00300A
0x0A00AC02
0x0A00BC02
0x0A027000
0x0A027100
0x0A02CC00
0x0A02CC01
0x0A02CC02
0x0A02DC00
0x0A02DC01
0x0A02DC02
0x0A030C00
0x0A030C01
0x0A030C02
0x0A031C00
0x0A031C01
0x0A031C02
0x0A034C00
0x0A034C02
0x0A035C00
0x0A035C02
0x0A036C00
0x0A036C01
0x0A036C02
0x0A037C00
0x0A037C01
0x0A037C02
0x0A03CC00
0x0A03DC00
0x0A040C00
0x0A040C02
0x0A041C00
0x0A041C02
0x0A07AC00
0x0A07AC02
0x0A07BC00
0x0A07BC02
0x0B026001
0x0B026002
0x0B026003
0x0B026004
0x0B026005
0x0B026006
0x0B026007
0x0B026008
0x0B026009
0x0B02600A
0x0D000281
0x0D000282
0x0D01E000
0x0E002001
0x0E002002
0x0E002003
0x0E002004
0x0E002005
0x0E002006
0x0E002007
0x0E002008
0x0E002009
0x0E00200A
0x0E00200B
0x0E00200C
0x0E00200D
0x0E00200E
0x0E004001
0x0E004002
0x0E004003
0x0E004004
0x0E004005
0x0E004006
0x0E004007
0x0E004008
0x0E004009
0x0E00400A
0x0E00400B
0x0E00400C
0x0E00400D
0x0E00400E
0x0E006001
0x0E006002
0x0E006003
0x0E006004
0x0E006005
0x0E006006
0x0E006007
0x0E006008
0x0E006009
0x0E00600A
0x0E00600B
0x0E00600C
0x0E00600D
0x0E00600E
0x0E008001
0x0E008002
0x0E008003
0x0E008004
0x0E008005
0x0E008006
0x0E008007
0x0E008008
0x0E008009
0x0E00800A
0x0E00800B
0x0E00800C
0x0E00800D
0x0E00800E
0x0E00A001
0x0E00A002
0x0E00A003
0x0E00A004
0x0E00A005
0x0E00A006
0x0E00A007
0x0E00A008
0x0E00A009
0x0E00A00A
0x0E00A00B
0x0E00A00C
0x0E00A00D
0x0E00A00E
0x0E00B001
0x0E00B002
0x0E00B003
0x0E00B004
0x0E00B005
0x0E00B006
0x0E00B007
0x0E00B008
0x0E00B009
0x0E00B00A
0x0E00C001
0x0E00C002
0x0E00C003
0x0E00C004
0x0E00C005
0x0E00C006
0x0E00C007
0x0E00C008
0x0E00C009
0x0E00C00A
0x0E00C00B
0x0E00C00C
0x0E00C00D
0x0E00C00E
0x0E00C28F
0x0E00D001
0x0E00D002
0x0E00D281
0x0E00D282
0x0E00D381
0x0E00D382
0x0E010001
0x0E010002
0x0E010003
0x0E010004
0x0E010005
0x0E010006
0x0E010007
0x0E010008
0x0E010009
0x0E01000A
0x0E01000B
0x0E01000C
0x0E01000D
0x0E01000E
0x0E012041
0x0E012042
0x0E012047
0x0E200001
0x0E200002
0x0E200003
0x0E200004
0x0E200005
0x0E200006
0x0E200007
0x0E200008
0x0E200009
0x0E20000A
0x0E20000B
0x0E20000C
0x0E20000D
0x0E20000E
0x0E418802
0x0E830402
0x0E830802
0x0E832402
0x0E832802
0x0E834402
0x0E834802
0x0E836402
0x0E836802
0x0E83C402
0x0E83C802
0x0E840402
0x0E840802
0x0E850402
0x0E850802
0x0E860402
0x0E860802
0x0E87A402
0x0E87A802
0x0EA00001
0x0EA00002
0x0EA00003
0x0EA00004
0x0EA00005
0x0EA00006
0x0EA00007
0x0EA00008
0x0EA00009
0x0EA0000A
0x0EA01001
0x0EA01002
0x0EA01003
0x0EA01004
0x0EA01005
0x0EA01006
0x0EA01007
0x0EA01008
0x0EA01009
0x0EA0100A
0x0EA02001
0x0EA02002
0x0EA02003
0x0EA02004
0x0EA02005
0x0EA02006
0x0EA02007
0x0EA02008
0x0EA02009
0x0EA0200A
0x0EA04001
0x0EA04002
0x0EA04003
0x0EA04004
0x0EA04005
0x0EA04006
0x0EA04007
0x0EA04008
0x0EA04009
0x0EA0400A
0x0EA05001
0x0EA05002
0x0EA05003
0x0EA05004
0x0EA05005
0x0EA05006
0x0EA05007
0x0EA05008
0x0EA05009
0x0EA0500A
0x0EA06001
0x0EA06002
0x0EA06003
0x0EA06004
0x0EA06005
0x0EA06006
0x0EA06007
0x0EA06008
0x0EA06009
0x0EA0600A
0x0EA08001
0x0EA08002
0x0EA08003
0x0EA08004
0x0EA08005
0x0EA08006
0x0EA08007
0x0EA08008
0x0EA08009
0x0EA0800A
0x0EA0A001
0x0EA0A002
0x0EA0A003
0x0EA0A004
0x0EA0A005
0x0EA0A006
0x0EA0A007
0x0EA0A008
0x0EA0A009
0x0EA0A00A
0x0EA0B001
0x0EA0B002
0x0EA0B003
0x0EA0B004
0x0EA0B005
0x0EA0B006
0x0EA0B007
0x0EA0B008
0x0EA0B009
0x0EA0B00A
0x0EA0C001
0x0EA0C002
0x0EA0C003
0x0EA0C004
0x0EA0C005
0x0EA0C006
0x0EA0C007
0x0EA0C008
0x0EA0C009
0x0EA0C00A
0x0EA0C101
0x0EA0C102
0x0EA0C103
0x0EA0C104
0x0EA0C105
0x0EA0C106
0x0EA0C107
0x0EA0C108
0x0EA0C109
0x0EA0C10A
0x0EA0D001
0x0EA0D002
0x0EA0D003
0x0EA0D004
0x0EA0D005
0x0EA0D006
0x0EA0D007
0x0EA0D008
0x0EA0D009
0x0EA0D00A
0x0EA0D201
0x0EA0D202
0x0EA0D203
0x0EA0D204
0x0EA0D205
0x0EA0D206
0x0EA0D207
0x0EA0D208
0x0EA0D209
0x0EA0D20A
0x0EA0D301
0x0EA0D302
0x0EA0D303
0x0EA0D304
0x0EA0D305
0x0EA0D306
0x0EA0D307
0x0EA0D308
0x0EA0D309
0x0EA0D30A
0x0EA0D401
0x0EA0D402
0x0EA0D403
0x0EA0D404
0x0EA0D405
0x0EA0D406
0x0EA0D407
0x0EA0D408
0x0EA0D409
0x0EA0D40A
0x0EA0D501
0x0EA0D502
0x0EA0D503
0x0EA0D504
0x0EA0D505
0x0EA0D506
0x0EA0D507
0x0EA0D508
0x0EA0D509
0x0EA0D50A
0x0EA0D601
0x0EA0D602
0x0EA0D603
0x0EA0D604
0x0EA0D605
0x0EA0D606
0x0EA0D607
0x0EA0D608
0x0EA0D609
0x0EA0D60A
0x0EA0D701
0x0EA0D702
0x0EA0D703
0x0EA0D704
0x0EA0D705
0x0EA0D706
0x0EA0D707
0x0EA0D708
0x0EA0D709
0x0EA0D70A
0x0EA0D801
0x0EA0D802
0x0EA0D803
0x0EA0D804
0x0EA0D805
0x0EA0D806
0x0EA0D807
0x0EA0D808
0x0EA0D809
0x0EA0D80A
0x0EA0D901
0x0EA0D902
0x0EA0D903
0x0EA0D904
0x0EA0D905
0x0EA0D906
0x0EA0D907
0x0EA0D908
0x0EA0D909
0x0EA0D90A
0x0EA0DB01
0x0EA0DB02
0x0EA0DB03
0x0EA0DB04
0x0EA0DB05
0x0EA0DB06
0x0EA0DB07
0x0EA0DB08
0x0EA0DB09
0x0EA0DB0A
0x0EA0DC01
0x0EA0DC02
0x0EA0DC03
0x0EA0DC04
0x0EA0DC05
0x0EA0DC06
0x0EA0DC07
0x0EA0DC08
0x0EA0DC09
0x0EA0DC0A
0x0EA0E001
0x0EA0E002
0x0EA0E003
0x0EA0E004
0x0EA0E005
0x0EA0E006
0x0EA0E007
0x0EA0E008
0x0EA0E009
0x0EA0E00A
0x0EA0E101
0x0EA0E102
0x0EA0E103
0x0EA0E104
0x0EA0E105
0x0EA0E106
0x0EA0E107
0x0EA0E108
0x0EA0E109
0x0EA0E10A
0x0EA0E201
0x0EA0E202
0x0EA0E203
0x0EA0E204
0x0EA0E205
0x0EA0E206
0x0EA0E207
0x0EA0E208
0x0EA0E209
0x0EA0E20A
0x0EA0E301
0x0EA0E401
0x0EA0E501
0x0EA0E601
0x0EA0E701
0x0EA0E702
0x0EA0E703
0x0EA0E704
0x0EA0E705
0x0EA0E706
0x0EA0E707
0x0EA0E708
0x0EA0E709
0x0EA0E70A
0x0EA0E801
0x0EA0E901
0x0EA0EA01
0x0EA0EA02
0x0EA0EA03
0x0EA0EA04
0x0EA0EA05
0x0EA0EA06
0x0EA0EA07
0x0EA0EA08
0x0EA0EA09
0x0EA0EA0A
0x0EA0EB01
0x0EA0EB02
0x0EA0EB03
0x0EA0EB04
0x0EA0EB05
0x0EA0EB06
0x0EA0EB07
0x0EA0EB08
0x0EA0EB09
0x0EA0EB0A
0x0EA0EC01
0x0EA0EC02
0x0EA0EC03
0x0EA0EC04
0x0EA0EC05
0x0EA0EC06
0x0EA0EC07
0x0EA0EC08
0x0EA0EC09
0x0EA0EC0A
0x0EA0ED01
0x0EA0ED02
0x0EA0ED03
0x0EA0ED04
0x0EA0ED05
0x0EA0ED06
0x0EA0ED07
0x0EA0ED08
0x0EA0ED09
0x0EA0ED0A
0x0EA0EE01
0x0EA0EE02
0x0EA0EE03
0x0EA0EE04
0x0EA0EE05
0x0EA0EE06
0x0EA0EE07
0x0EA0EE08
0x0EA0EE09
0x0EA0EE0A
0x0EA0F001
0x0EA0F002
0x0EA0F003
0x0EA0F004
0x0EA0F005
0x0EA0F006
0x0EA0F007
0x0EA0F008
0x0EA0F009
0x0EA0F00A
0x0EA0F101
0x0EA0F102
0x0EA0F103
0x0EA0F104
0x0EA0F105
0x0EA0F106
0x0EA0F107
0x0EA0F108
0x0EA0F109
0x0EA0F10A
0x0EA0F201
0x0EA0F202
0x0EA0F203
0x0EA0F204
0x0EA0F205
0x0EA0F206
0x0EA0F207
0x0EA0F208
0x0EA0F209
0x0EA0F20A
0x0EA0F301
0x0EA0F302
0x0EA0F303
0x0EA0F304
0x0EA0F305
0x0EA0F306
0x0EA0F307
0x0EA0F308
0x0EA0F309
0x0EA0F30A
0x0EA0F401
0x0EA0F402
0x0EA0F403
0x0EA0F404
0x0EA0F405
0x0EA0F406
0x0EA0F407
0x0EA0F408
0x0EA0F409
0x0EA0F40A
0x0EA0F501
0x0EA0F502
0x0EA0F503
0x0EA0F504
0x0EA0F505
0x0EA0F506
0x0EA0F507
0x0EA0F508
0x0EA0F509
0x0EA0F50A
0x0EA0F601
0x0EA0F602
0x0EA0F603
0x0EA0F604
0x0EA0F605
0x0EA0F606
0x0EA0F607
0x0EA0F608
0x0EA0F609
0x0EA0F60A
0x0EA0F701
0x0EA0F702
0x0EA0F703
0x0EA0F704
0x0EA0F705
0x0EA0F706
0x0EA0F707
0x0EA0F708
0x0EA0F709
0x0EA0F70A
0x0EA0F801
0x0EA0F802
0x0EA0F803
0x0EA0F804
0x0EA0F805
0x0EA0F806
0x0EA0F807
0x0EA0F808
0x0EA0F809
0x0EA0F80A
0x0EA0F901
0x0EA0F902
0x0EA0F903
0x0EA0F904
0x0EA0F905
0x0EA0F906
0x0EA0F907
0x0EA0F908
0x0EA0F909
0x0EA0F90A
0x0EA0FA01
0x0EA0FA02
0x0EA0FA03
0x0EA0FA04
0x0EA0FA05
0x0EA0FA06
0x0EA0FA07
0x0EA0FA08
0x0EA0FA09
0x0EA0FA0A
0x0EA0FB01
0x0EA0FB02
0x0EA0FB03
0x0EA0FB04
0x0EA0FB05
0x0EA0FB06
0x0EA0FB07
0x0EA0FB08
0x0EA0FB09
0x0EA0FB0A
0x0EA0FC01
0x0EA0FC02
0x0EA0FC03
0x0EA0FC04
0x0EA0FC05
0x0EA0FC06
0x0EA0FC07
0x0EA0FC08
0x0EA0FC09
0x0EA0FC0A
0x0EA0FD01
0x0EA0FD02
0x0EA0FD03
0x0EA0FD04
0x0EA0FD05
0x0EA0FD06
0x0EA0FD07
0x0EA0FD08
0x0EA0FD09
0x0EA0FD0A
0x0EA0FE01
0x0EA0FE02
0x0EA0FE03
0x0EA0FE04
0x0EA0FE05
0x0EA0FE06
0x0EA0FE07
0x0EA0FE08
0x0EA0FE09
0x0EA0FE0A
0x0EA0FF01
0x0EA0FF02
0x0EA0FF03
0x0EA0FF04
0x0EA0FF05
0x0EA0FF06
0x0EA0FF07
0x0EA0FF08
0x0EA0FF09
0x0EA0FF0A
0x0EA12001
0x0EA12002
0x0EA12003
0x0EA12004
0x0EA12005
0x0EA12006
0x0EA12007
0x0EA12008
0x0EA12009
0x0EA1200A
0x0EA14001
0x0EA14002
0x0EA14003
0x0EA14004
0x0EA14005
0x0EA14006
0x0EA14007
0x0EA14008
0x0EA14009
0x0EA1400A
0x0EA15001
0x0EA15002
0x0EA15003
0x0EA15004
0x0EA15005
0x0EA15006
0x0EA15007
0x0EA15008
0x0EA15009
0x0EA1500A
0x0EA16001
0x0EA16002
0x0EA1A401
0x0EA1A402
0x0EA1A403
0x0EA1A404
0x0EA1A405
0x0EA1A406
0x0EA1A407
0x0EA1A408
0x0EA1A409
0x0EA1A40A
0x0EA1C401
0x0EA1C402
0x0EA1C403
0x0EA1C404
0x0EA1C405
0x0EA1C406
0x0EA1C407
0x0EA1C408
0x0EA1C409
0x0EA1C40A
0x0EA1D401
0x0EA1D402
0x0EA1D403
0x0EA1D404
0x0EA1D405
0x0EA1D406
0x0EA1D407
0x0EA1D408
0x0EA1D409
0x0EA1D40A
0x0EC00001
0x0EC00002
0x0EE00000
0x0EE18000
0x0F00A001
0x0F00A002
0x0F00A003
0x0F00A004
0x0F00A005
0x0F00A006
0x0F00A007
0x0F00A008
0x0F00A009
0x0F00A00A
0x0F00A00B
0x0F00A00C
0x0F00A00D
0x0F00A00E
0x0F00B001
0x0F00B002
0x0F00B003
0x0F00B004
0x0F00B005
0x0F00B006
0x0F00B007
0x0F00B008
0x0F00B009
0x0F00B00A
0x0F00B00B
0x0F00B00C
0x0F00B00D
0x0F00B00E
0x0F00C001
0x0F00C002
0x0F00C003
0x0F00C004
0x0F00C005
0x0F00C006
0x0F00C007
0x0F00C008
0x0F00C009
0x0F00C00A
0x0F00C00B
0x0F00C00C
0x0F00C00D
0x0F00C00E
0x0F00D001
0x0F00D002
0x0F00D003
0x0F00D004
0x0F00D005
0x0F00D006
0x0F00D007
0x0F00D008
0x0F00D009
0x0F00D00A
0x0F00D00B
0x0F00D00C
0x0F00D00D
0x0F00D00E
0x0F00E001
0x0F00E002
0x0F00E003
0x0F00E004
0x0F00E005
0x0F00E006
0x0F00E007
0x0F00E008
0x0F00E009
0x0F00E00A
0x0F00E00B
0x0F00E00C
0x0F00E00D
0x0F00E00E
0x0F00F001
0x0F00F002
0x0F00F003
0x0F00F004
0x0F00F005
0x0F00F006
0x0F00F007
0x0F00F008
0x0F00F009
0x0F00F00A
0x0F00F00B
0x0F00F00C
0x0F00F00D
0x0F00F00E
0x0F010001
0x0F010002
0x0F010003
0x0F010004
0x0F010005
0x0F010006
0x0F010007
0x0F010008
0x0F010009
0x0F01000A
0x0F01000B
0x0F01000C
0x0F01000D
0x0F01000E
0x0F010101
0x0F010102
0x0F010103
0x0F010104
0x0F010105
0x0F010106
0x0F010107
0x0F010108
0x0F010109
0x0F01010A
0x0F01010B
0x0F01010C
0x0F01010D
0x0F01010E
0x10016000
0x1C000001
0x1C000002
0x1C000003
0x1C000004
0x1E00D001
0x1E00D002
0x1E00D003
0x1E00D004
0x1E00D005
0x1E00D006
0x1E00D007
0x1E00D008
0x1E00D009
0x1E00D00A
0x1E00D00B
0x1E00D00C
0x1E00D00D
0x1E00D00E
0x1E00E001
0x1E00E002
0x1E00E003
0x1E00E004
0x1E00E005
0x1E00E006
0x1E00E007
0x1E00E008
0x1E00E009
0x1E00E00A
0x1E00E00B
0x1E00E00C
0x1E00E00D
0x1E00E00E
0x1E00F001
0x1E00F002
0x1E00F003
0x1E00F004
0x1E00F005
0x1E00F006
0x1E00F007
0x1E00F008
0x1E00F009
0x1E00F00A
0x1E00F00B
0x1E00F00C
0x1E00F00D
0x1E00F00E
0x1E00F00F
0x1E010012
0x40000010
0x40000011
0x40000012
0x40000013
0x40000014
0x40000015
0x40000016
0x40000020
0x40000022
0x40000030
0x40001001
0x40001002
0x40001003
0x40001004
0x40001005
0x40001007
0x40001008
0x4000100A
0x40001006
0x40001009
0x40001020
0x40001021
0x40001022
0x40001023
0x40001024
0x40001025
0x40001026
0x40001027
0x40015070
0x40015080
0x40015090
0x4001711E
0x40110001
0x40110002
0x40217006
0x40217007
0x40217008
0x40324001
0x40324002
0x40324003
0x40324004
0x40324005
0x40324006
0x40324007
0x40324008
0x40324009
0x4032400A
0x40324101
0x40324102
0x40324103
0x40324104
0x40324105
0x40324106
0x40324107
0x40324108
0x40324109
0x4032410A
0x40324201
0x40324202
0x40324203
0x40324204
0x40324205
0x40324206
0x40324207
0x40324208
0x40324209
0x4032420A
0x40324301
0x40324302
0x40324303
0x40324304
0x40324305
0x40324306
0x40324307
0x40324308
0x40324309
0x4032430A
0x40324401
0x40324402
0x40324403
0x40324404
0x40324405
0x40324406
0x40324407
0x40324408
0x40324409
0x4032440A
0x40324501
0x40324502
0x40324503
0x40324504
0x40324505
0x40324506
0x40324507
0x40324508
0x40324509
0x4032450A
0x40324601
0x40324602
0x40324603
0x40324604
0x40324605
0x40324606
0x40324607
0x40324608
0x40324609
0x4032460A
0x40324701
0x40324702
0x40324703
0x40324704
0x40324705
0x40324706
0x40324707
0x40324708
0x40324709
0x4032470A
0x40324801
0x40324802
0x40324803
0x40324804
0x40324805
0x40324806
0x40324807
0x40324808
0x40324809
0x4032480A
0x40324901
0x40324902
0x40324903
0x40324904
0x40324905
0x40324906
0x40324907
0x40324908
0x40324909
0x4032490A
0x40324A01
0x40324A02
0x40324A03
0x40324A04
0x40324A05
0x40324A06
0x40324A07
0x40324A08
0x40324A09
0x40324A0A
0x40524901
0x40524902
0x40524903
0x40524904
0x40524905
0x40524906
0x40524907
0x40524908
0x40524909
0x4052490A
0x40624901
0x40624902
0x43000101
0x43000102
0x43000103
0x43000104
0x43000105
0x43000106
0x43000108
0x43000109
0x4300010A
0x4300010B
0x4300010C
0x4300010D
0x4300010E
0x43000500
0x48008401
0x48008402
0x4800A400
0x64001000
0x6E000001
0x6F100000
0x6F100001
0x6F200000
0x6F300000
0x6F500000
0x6F600001
0x6F600002
0x6F600101
0x6F600102
0x6F601001
0x6F601002
0x6F601101
0x6F601102
0x6F602001
0x6F602002
0x6F602003
0x6F602004
0x6F602005
0x6F602006
0x6F602007
0x6F602008
0x6F602009
0x6F60200A
0x6F602101
0x6F602102
0x6F602103
0x6F602104
0x6F602105
0x6F602106
0x6F602107
0x6F602108
0x6F602109
0x6F60210A
0x6F603001
0x6F603002
0x6F603003
0x6F603004
0x6F603005
0x6F603006
0x6F603007
0x6F603008
0x6F603009
0x6F60300A
0x6F603101
0x6F603102
0x6F603103
0x6F603104
0x6F603105
0x6F603106
0x6F603107
0x6F603108
0x6F603109
0x6F60310A
0x6F608001
0x6F608002
0x6F609001
0x6F609002
0x6F609101
0x6F609102
0x6F60A001
0x6F60A002
0x6F60A003
0x6F60A101
0x6F60A201
0x6F60A401
0x6F60B001
0x6F60B101
0x6F60C001
0x6F60C002
0x6F60C101
0x6F60C102
0x6F60C201
0x6F60C202
0x6F60D001
0x6F60D002
0x6F60F001
0x6F60F002
0x6F700001
0x6F700002
0x6F700003
0x6F700004
0x6F700005
0x6F800001
0x6F800002
0x6F800101
0x6F800102
0x6F800301
0x6F800302
0x6F800401
0x6F800402
0x6F800501
0x6F800502
0x6F800601
0x6F800602
0x6F801001
0x6F801002
0x6F801003
0x6F801004
0x6F801005
0x6F801006
0x6F801007
0x6F801008
0x6F801009
0x6F80100A
0x6F80100B
0x6F80100C
0x6F801101
0x6F801102
0x6F801103
0x6F801104
0x6F801105
0x6F801106
0x6F801107
0x6F801108
0x6F801109
0x6F80110A
0x6F80110B
0x6F80110C
0x6F801201
0x6F801202
0x6F801203
0x6F801204
0x6F801205
0x6F801206
0x6F801207
0x6F801208
0x6F801209
0x6F80120A
0x6F80120B
0x6F80120C
0x6F801301
0x6F801302
0x6F801303
0x6F801304
0x6F801305
0x6F801306
0x6F801307
0x6F801308
0x6F801309
0x6F80130A
0x6F80130B
0x6F80130C
0x6F801401
0x6F801402
0x6F801403
0x6F801404
0x6F801405
0x6F801406
0x6F801407
0x6F801408
0x6F801409
0x6F80140A
0x6F80140B
0x6F80140C
0x6F801501
0x6F801502
0x6F801503
0x6F801504
0x6F801505
0x6F801506
0x6F801507
0x6F801508
0x6F801509
0x6F80150A
0x6F80150B
0x6F80150C
0x6F801601
0x6F801602
0x6F801603
0x6F801604
0x6F801605
0x6F801606
0x6F801607
0x6F801608
0x6F801609
0x6F80160A
0x6F80160B
0x6F80160C
0x6F801701
0x6F801702
0x6F801703
0x6F801704
0x6F801705
0x6F801706
0x6F801707
0x6F801708
0x6F801709
0x6F80170A
0x6F80170B
0x6F80170C
0x6F802001
0x6F802002
0x6F802101
0x6F802102
0x6F803001
0x6F803002
0x6F900001
0x6F900002
0x6F900003
0x6F900004
0x6F901001
0x6F901002
0x6F901003
0x6F901004
0x6FA00001
0x6FA01001
0x6FA02001
0x800000FF
0x80010000
0x80010200
0x80010400
0x80010700
0x80010701
0x80010702
0x80010002
0x80010900
0x80010901
0x80010902
0x80010202
0x80010B00
0x80010B01
0x80010B02
0x80010402
0x80030100
0x80070000
0x80070100
0x80070200
0x80070300
0x80070500
0x80070600
0x80080000
0x80090000
0x800B0100
0x800B0300
0x800B0400
0x800B0500
0x806F0007
0x806F0009
0x806F000D
0x806F002C
0x806F000F
0x806F0013
0x806F001E
0x806F001F
0x806F011F
0x806F021F
0x806F041F
0x806F0021
0x806F0029
0x806F002B
0x806F0107
0x806F0108
0x806F0109
0x806F010C
0x806F010D
0x806F010F
0x806F0112
0x806F0113
0x806F011B
0x806F0120
0x806F0129
0x806F012B
0x806F0207
0x806F0208
0x806F020D
0x806F020F
0x806F0212
0x806F0229
0x806F030C
0x806F0313
0x806F032B
0x806F0407
0x806F0409
0x806F040C
0x806F0413
0x806F0507
0x806F0509
0x806F050C
0x806F050D
0x806F0513
0x806F0521
0x806F052B
0x806F0607
0x806F0609
0x806F060C
0x806F060D
0x806F0707
0x806F070C
0x806F070D
0x806F0807
0x806F0813
0x806F0A07
0x806F0A13
Setting up Serial over LAN
Introduction
Hardware and firmware requirements
Hardware requirements
Firmware requirements
Checking firmware versions
Starting the BladeCenter management-module Web interface
General configuration
Configuring the global SOL settings for the BladeCenter unit
Configuring the management module
Installing and configuring SSH for SOL
Enabling SOL for blade servers
Updating and configuring the blade server BIOS
Operating system configuration
Linux configuration
Red Hat Enterprise Linux ES 2.1 configuration
SUSE SLES 8.0 configuration
Installing the Ethernet controller device driver for Linux operating systems
Microsoft Windows 2003 Standard Edition configuration
Special component requirements
Configuring the BladeCenter HS22 Type 7870 blade server
Configuring the BladeCenter HS20 Type 8832 and HS20 Type 8843 blade servers
HS20 Type 8832 SOL jumper placement
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the BladeCenter HS40 Type 8839 blade server
Updating the Baseboard Management Controller firmware
Updating and configuring the BIOS
Configuring the BladeCenter JS20 Type 8842 blade server
Updating the open firmware (BIOS)
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the IBM 4-Port Gb Ethernet Switch Module for BladeCenter
Configuring the Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter
Configuring the Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM BladeCenter
Connecting an Intelligent Copper Pass-thru Module
Using SOL
Starting an SOL session
Starting a command-line Telnet connection
Establishing a serial connection
Starting a command-line Secure Shell (SSH) connection
Starting an SOL session from the command-line interface
Ending an SOL session
Monitoring SOL session status
Restarting a blade server through SOL
Mounting and unmounting media for Linux operating systems
Troubleshooting SOL
Management module indicates that blade server does not support SOL
Blade server shows SOL status of Not Ready
SOL session opens and drops
Trouble entering SOL commands or receiving double prompts
Garbage characters in an SOL session
IBM BladeCenter Open Fabric Manager
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
BladeCenter Open Fabric Manager
Requirements
Hardware requirements
Supported software
License information
Accessibility
Documentation and related information
Notices and statements in this document
Overview
Configuration file
Sample configuration file
Mapping of devices to ports
Multi-slot blades and the port offset parameter
Standby AMM
Preparing for BOFM
Upgrading firmware
Setting up boot from SAN
Basic BOFM
AMM Web interface
Installing BOFM
Session and credentials
Configuring
Creating a configuration file automatically
Selecting domains
Avoiding address duplication
Resolving duplicate address errors
Creating a requirements report
Editing the configuration file manually
Applying a new configuration
Viewing the configuration in a local chassis
Retrieving the current configuration
Using Basic BOFM
Initial deployment
Adding a new chassis to the domain
Replacing a blade in the same slot
Swapping addresses between blades
Replacing AMM IP addresses
Replacing the AMM in a single AMM environment
CLI command
Advanced BOFM
Stand-alone version for Windows
Stand-alone version for Linux
Importing BOFM-Advanced upgrade
Using Advanced BOFM
Starting Advanced BOFM
Adding chassis inventory
Managing chassis inventory
Managing blade inventory
Creating or importing an address manager template
Managing an address manager template
Creating a standby blade pool template
Managing a standby blade pool template
Creating a failover monitor
Managing a failover monitor
Troubleshooting
Basic BOFM troubleshooting
Events
BOFM address usage
Configuration failure scenarios
Error messages
Advanced BOFM troubleshooting
Common problems
Problems when you create or apply a standby blade pool
BOFM To IBM Fabric Manager Migration
Steps for BOFM to IBM Fabric Manager (IFM) migration
BOFM Basic to IFM Migration Option 1 – Do Nothing
BOFM Basic to IFM Migration Option 2 – Import CSV File
BOFM Basic to IFM Migration Option 3 – Create Deployment by Harvesting from BladeCenter
BOFM Basic to IFM Migration Option 4 – Start Over
Management module
PDF files
Installing
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Using the Web interface
The BladeCenter management module
Accessibility features for the BladeCenter management module
Related documentation
Notices and statements in this documentation
Using the management-module Web interface
Connecting to the management module
Management-module connection overview
Hardware requirements
Software requirements
Cabling the management module
Networked connection
Direct connection
Connecting to the management module for the first time
Starting the management-module Web interface
Configuring the management module
Configuring the management module for remote access
Configuring the management-module Ethernet ports
Communicating with the IBM Director software
Configuring advanced features
Network and security configuration
Configuring SNMP
Configuring SMTP
Configuring LDAP
Secure Web server and secure LDAP
Configuring the Secure Shell (SSH) server
Configuring Wake on LAN
Verifying the Wake on LAN configuration
Linux-specific configuration
Using the configuration file
Backing up your management-module configuration
Restoring and modifying your management-module configuration
Using the remote disk feature
Mounting a disk drive or disk image
Unmounting a disk drive or disk image
Configuring an I/O module
Management-module Web interface overview
Web interface pages and user roles
Management-module Web interface options
Monitors
System Status
BladeCenter T alarm management
BladeCenter unit detailed component status
Event Log
LEDs
BladeCenter unit LEDs
BladeCenter T alarm management
Fuel Gauge
Detailed power information
Hardware VPD
Firmware VPD
Blade Tasks
Power/Restart
Remote Control
Firmware Update
Configuration
Serial Over LAN
I/O Module Tasks
Admin/Power/Restart
Configuration
Firmware Update
MM Control
General Settings
Login Profiles
Alerts
Port Assignments
Network Interfaces
Network Protocols
Security
Configuration File
Firmware Update
Restore Defaults
Restart MM
Using the command-line interface
Introduction
Before you begin
Accessibility features for the BladeCenter management module
Using the command-line interface
Command-line interface guidelines
Selecting the command target
Commands and user authority
Cabling the management module
Networked connection
Direct connection
Starting the command-line interface
Telnet connection
Secure Shell (SSH) connection
Using the Secure Shell server
BladeCenter unit configuration
Configuring the management module
Starting an SOL session
Ending an SOL session
Command reference
Alphabetic command list
Command list by function
Command syntax
alarm command (BladeCenter T only)
alertentries command
boot command
clear command
clearlog command
clock command
config command
console command
dhcpinfo command
displaylog command
dns command
env (environment) command
exit command
fuelg command
health command
help command
history command
identify (location LED) command
ifconfig command
info (configuration information) command
kvm (keyboard, video, mouse) command
list (system physical configuration) command
mt (media tray) command
power command
reset command
shutdown command
slp command
smtp command
snmp command
sol (serial over LAN) command
tcpcmdmode command
telnetcfg (Telnet configuration) command
update (update firmware) command
uplink (management module failover) command
users command
Error messages
Common errors
alarm command errors
alertentries command errors
boot command errors
clear command errors
clearlog command errors
clock command errors
config command errors
console command errors
dhcpinfo command errors
displaylog command errors
dns command errors
env command errors
exit command errors
fuelg command errors
health command errors
help command errors
history command errors
identify command errors
ifconfig command errors
info command errors
kvm command errors
list command errors
mt command errors
power command errors
reset command errors
shutdown command errors
slp command errors
smtp command errors
snmp command errors
sol command errors
tcpcmdmode command errors
telnetcfg command errors
update command errors
uplink command errors
users command errors
Setting up Serial over LAN
Introduction
Hardware and firmware requirements
Hardware requirements
Firmware requirements
Checking firmware versions
Starting the BladeCenter management-module Web interface
General configuration
Configuring the global SOL settings for the BladeCenter unit
Configuring the management module
Installing and configuring SSH for SOL
Enabling SOL for blade servers
Updating and configuring the blade server BIOS
Operating system configuration
Linux configuration
Red Hat Enterprise Linux ES 2.1 configuration
SUSE SLES 8.0 configuration
Installing the Ethernet controller device driver for Linux operating systems
Microsoft Windows 2003 Standard Edition configuration
Special component requirements
Configuring the BladeCenter HS22 Type 7870 blade server
Configuring the BladeCenter HS20 Type 8832 and HS20 Type 8843 blade servers
HS20 Type 8832 SOL jumper placement
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the BladeCenter HS40 Type 8839 blade server
Updating the Baseboard Management Controller firmware
Updating and configuring the BIOS
Configuring the BladeCenter JS20 Type 8842 blade server
Updating the open firmware (BIOS)
Updating the integrated systems management processor firmware
Updating the Broadcom Ethernet controller firmware
Configuring the IBM 4-Port Gb Ethernet Switch Module for BladeCenter
Configuring the Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter
Configuring the Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM BladeCenter
Connecting an Intelligent Copper Pass-thru Module
Using SOL
Starting an SOL session
Starting a command-line Telnet connection
Establishing a serial connection
Starting a command-line Secure Shell (SSH) connection
Starting an SOL session from the command-line interface
Ending an SOL session
Monitoring SOL session status
Restarting a blade server through SOL
Mounting and unmounting media for Linux operating systems
Troubleshooting SOL
Management module indicates that blade server does not support SOL
Blade server shows SOL status of Not Ready
SOL session opens and drops
Trouble entering SOL commands or receiving double prompts
Garbage characters in an SOL session
Blade servers
HS12 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Safety and environmental notices
Notices and statements
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
IBM Statement of Limited Warranty Z125-4753-09 08/2006
Part 1 - General Terms
Part 2 - Country-unique Terms
Part 3 - Warranty Information
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing options
Removing the blade server from the BladeCenter unit
Opening the blade server cover
Removing an optional expansion unit
Installing a fixed-storage drive
Installing a hot-swap storage drive
Installing a memory module
Installing a concurrent KVM card
I/O expansion cards
Installing an I/O expansion card
Installing a high-speed expansion card
Installing an optional expansion unit
Completing the installation
Closing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Configuration/Setup Utility program
Configuration/Setup Utility menu
Using passwords
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Typical operating-system installation
Installing the operating system without using ServerGuide
Using the PXE boot agent utility program
Firmware updates
Configuring the Gigabit Ethernet controller
Configuring a SAS RAID array
Using the LSI Logic Configuration Utility program
Installing the operating system
Using the ServerGuide Setup and Installation CD to install the operating system
Using RDM to install the operating system
Downloading installation instructions
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools
POST
POST beep codes
Beep code descriptions
No-beep symptoms
Error logs
Viewing the BMC log from the Configuration/Setup Utility program
Viewing the BMC log from the diagnostic programs
BMC error messages
POST error codes
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
BMC self tests
Broadcom Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Microprocessor problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Recovering from a BIOS update failure
Service processor (BMC) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Solving undetermined problems
Removing and replacing blade server components
Parts listing, Types 8014, 8028 and 1916
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 customer replaceable units (CRUs)
Removing the blade server cover
Installing the blade server cover
Removing an optional expansion unit
Installing an optional expansion unit
Removing the bezel assembly
Installing the bezel assembly
Removing a fixed-storage drive
Installing a fixed-storage drive
Removing a hot-swap storage drive
Installing a hot-swap storage drive
Removing a memory module
Installing a memory module
Removing a concurrent KVM card
Installing a concurrent KVM card
Removing an I/O expansion card
Installing an I/O expansion card
Removing a storage interface card
Installing a storage interface card
Removing a high-speed expansion card
Installing a high-speed expansion card
Removing the battery
Installing the battery
Removing and replacing field replaceable units
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS20 Blade Server
Installing
Troubleshooting
Warranty
HS21 Blade Server
Installing
Troubleshooting
Warranty
HS21 XM Blade Server
Installing
Troubleshooting
Warranty
HS22 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety and environmental notices
Notices and statements in this document
Safety
Guidelines for trained technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Opening the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a hot-swap SAS drive
Removing a hot-swap SAS drive
Installing a memory module
Removing a memory module
Installing a USB module
Installing a USB module
I/O expansion cards
Installing a compact-form-factor expansion card
Removing a compact-form-factor expansion card
Installing a CIOv expansion card
Removing a CIOv-form-factor expansion card
Installing a storage interface card
Removing a storage interface card
Completing the installation
Closing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu choices
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Typical operating-system installation
Installing the operating system without using ServerGuide
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controllers
Configuring a SAS RAID array
Using the LSI Logic Configuration Utility program
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
For IPMI Windows Server 2003 R2 based operating systems
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Installing the operating system
Using the ServerGuide Setup and Installation CD to install the operating system
Using RDM to install the operating system
Downloading installation instructions
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools
POST
Error logs
Viewing the IMM log through the Setup utility
Viewing event logs withoug restarting the blade server
IMM error messages
POST error codes
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs in the blade server
Light path diagnostics LEDs
Viewing the light path diagnostics LEDs in the BladeCenter GPU expansion unit
BladeCenter GPU expansion unit light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM self tests
Broadcom Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Recovering from a UEFI update failure
In-band manual recover method
Out-of-band manual recover method
In-band automated boot recovery method
Out-of-band automated boot recovery method
Automated boot recovery (ABR)
Nx boot failure
Service processor (IMM) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing
Parts listing - BladeCenter HS22
Parts listing - BladeCenter GPU expansion unit
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from a BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 CRUs
Removing the blade server cover
Installing the blade server cover
Removing a blade handle
Installing a blade handle
Removing a hot-swap SAS drive
Installing a hot-swap SAS drive
Removing a memory module
Installing a memory module
Removing a USB module
Installing a USB module
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a compact-form-factor expansion card
Removing a storage interface card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a compact-form-factor expansion card
Installing a storage interface card
Removing and replacing Tier 2 CRUs
Removing the bezel assembly
Installing the bezel assembly
Removing the control panel
Installing the control panel
Removing and replacing FRUs
Removing an optional expansion unit
Installing an optional expansion unit
Removing a GPU adapter from an expansion unit
Installing a GPU adapter in an expansion unit
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Removing and replacing consumable parts
Removing the battery
Installing the battery
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS22V Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
Blade server connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Removing the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a SSD storage drive
Removing a SSD storage drive
Installing a memory module
Removing a memory module
Installing a USB Flash key
Removing a USB Flash key
I/O expansion cards
Installing a horizontal-combination-form-factor expansion card
Removing a horizontal-combination-form-factor expansion card
Installing a CIOv-form-factor expansion card
Removing a CIOv-form-factor expansion card
Installing a storage interface card
Removing a storage interface card
Completing the installation
Closing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Installing the operating system
Typical operating-system installation
Using the ServerGuide Setup and Installation CD to install the operating system
Installing the operating system without using ServerGuide
Using RDM to install the operating system
Downloading installation instructions
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controller
Configuring a RAID array
Using the LSI Logic Configuration Utility program
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
For IPMI Windows Server 2003 R2 based operating systems - IBM BladeCenter HS22V
LAN over USB Windows Driver Installation - IBM BladeCenter HS22V
LAN over USB Linux Driver Installation
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools overview
POST
Error logs
Viewing event logs through the Setup utility
Viewing event logs without restarting the blade server
IMM error messages
POST error codes
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM I2C tests
Broadcom Ethernet device tests
CPU stress tests
Memory I2C tests
Optical drive
Storage drive tests
Tape alert flags
Service processor (IMM) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Storage drive tests
Recovering from a UEFI update failure
In-band manual recovery method
Out-of-band manual recovery method
In-band automated boot recovery method
Out-of-band automated boot recovery method
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing, Types 7871 and 1949
Removing and replacing blade server components
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 customer replaceable units (CRUs)
Removing the blade server cover
Closing the blade server cover
Removing an optional expansion unit
Installing an optional expansion unit
Removing the bezel assembly
Installing the bezel assembly
Removing a SSD storage drive
Installing a SSD storage drive
Removing a memory module
Installing a memory module
Removing a USB Flash key
Installing a USB Flash key
Removing the battery
Installing the battery
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a horizontal-combination-form-factor expansion card
Removing a storage interface card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a horizontal-combination-form-factor expansion card
Installing a storage interface card
Removing and replacing Tier 2 customer replaceable units (CRUs)
Removing an SSD storage tray
Installing an SSD storage tray
Removing and replacing field replaceable units
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS23 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety
Guidelines for trained technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Taiwan BSMI RoHS declaration
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Removing the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a hot-swap storage drive
Removing a hot-swap storage drive
Installing a memory module
Removing a memory module
Installing a USB module
Removing a USB module
I/O expansion cards
Installing a compact-form-factor expansion card
Removing a compact-form-factor expansion card
Installing a CIOv expansion card
Removing a CIOv-form-factor expansion card
Installing a 10Gb LOM interposer card
Removing a 10Gb LOM interposer card
Completing the installation
Installing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Installing the operating system
Typical operating-system installation
Using the ServerGuide Setup and Installation CD to install the operating system
Installing the operating system without using ServerGuide
Using RDM to install the operating system
Downloading installation instructions
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controllers
Configuring a RAID array
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Troubleshooting
Diagnostics
Service bulletins
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Diagnostic tools
Event logs
Viewing the IMM log through the Setup utility
Viewing event logs withoug restarting the blade server
POST
POST/UEFI diagnostic codes
IMM error messages
Troubleshooting tables
General problems
Hard disk drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs in the blade server
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM self tests
Emulex Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Recovering from a UEFI update failure
In-band manual recovery method
Out-of-band manual recovery method
In-band automated boot recovery method
Out-of-band automated boot recovery method
Automated boot recovery (ABR)
Nx boot failure
Service processor (IMM) error codes
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing
Parts listing, Types 7875 and 1929
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from a BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing Tier 1 CRUs
Removing a hot-swap storage drive
Installing a hot-swap storage drive
Removing a memory module
Installing a memory module
Removing a USB module
Installing a USB module
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a compact-form-factor expansion card
Removing a 10Gb interposer card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a compact-form-factor expansion card
Installing a 10Gb interposer card
Removing the battery
Installing the battery
Removing the control panel
Installing the control panel
Removing a blade handle
Installing a blade handle
Removing and replacing Tier 2 CRUs
Removing an optional expansion unit
Installing an optional expansion unit
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Removing and replacing consumable and structural parts
Removing the blade server cover
Installing the blade server cover
Removing the bezel assembly
Installing the bezel assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HS23E Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
Major components of the blade server
Related documentation
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
Safety statements
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Turning on the blade server
Turning off the blade server
Blade server connectors
System-board layouts
System-board connectors
System-board switches
System-board LEDs
Installing Options
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from the BladeCenter unit
Removing the blade server cover
Installing an optional expansion unit
Removing an optional expansion unit
Installing a memory module
Removing a memory module
Installing a USB module
Removing a USB module
I/O expansion cards
Installing a compact-form-factor expansion card
Removing a compact-form-factor expansion card
Installing a CIOv expansion card
Removing a CIOv-form-factor expansion card
Removing a storage interface card
Installing a storage interface card
Removing the control panel
Installing the control panel
Completing the installation
Installing the blade server cover
Installing the blade server in a BladeCenter unit
Updating the blade server configuration
Input/output connectors and devices
Configuring the blade server
Using the Setup utility
Setup utility menu
Using passwords
Using the Boot Menu program
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the ServerGuide Setup and Installation CD
ServerGuide features
Setup and configuration overview
Installing the operating system
Typical operating-system installation
Using the ServerGuide Setup and Installation CD to install the operating system
Installing the operating system without using ServerGuide
Using the PXE boot agent utility program
Firmware updates
Configuring UEFI compatible devices
Configuring the Gigabit Ethernet controllers
Using the LSI Logic Configuration Utility program
Starting the LSI Configuration Utility program
Starting the HII Configuration Application
Creating a RAID array
Creating a software RAID array of hard disk drives
Setting Option ROM Execution Order
Using LAN over USB to interface the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Troubleshooting
Problem determination tips
Diagnostics
Diagnostic tools
POST
Error logs
Viewing the IMM log through the Setup utility
Viewing event logs withoug restarting the blade server
IMM error messages
POST error codes
Checkout procedure
About the checkout procedure
Performing the checkout procedure
Troubleshooting tables
General problems
Storage drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Software problems
Universal Serial Bus (USB) port problems
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
Dynamic system analysis diagnostic programs and messages
Running the diagnostic programs
Diagnostic text messages
Viewing the test log
Diagnostic messages
IMM self tests
Broadcom Ethernet device tests
CPU stress tests
Memory self tests
Optical drive self tests
Storage drive self tests
Tape alert flags
Recovering from a UEFI update failure
In-band manual recover method
Out-of-band manual recover method
In_band_automated_recovery
Out_of_band_automated_recovery
Service processor (IMM) error codes
Automated boot recovery (ABR)
Nx boot failure
Solving SAS hard disk drive problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Storage drive self tests
Solving undetermined problems
Problem determination tips
Removing and replacing blade server components
Parts listing
Parts listing, Types 8038 and 8039
Consumable and structural Parts
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing the blade server from a BladeCenter unit
Installing the blade server in a BladeCenter unit
Removing and replacing blade server components
Removing the blade server cover
Installing the blade server cover
Removing the bezel assembly
Installing the bezel assembly
Removing a blade handle
Installing a blade handle
Removing the air baffle
Installing the air baffle
Removing and replacing Tier 1 CRUs
Removing the battery
Installing the battery
Removing a hot-swap SAS drive
Installing a hot-swap SAS drive
Removing a memory module
Installing a memory module
Removing a USB module
Installing a USB module
Removing an I/O expansion card
Removing a CIOv-form-factor expansion card
Removing a compact-form-factor expansion card
Installing an I/O expansion card
Installing a CIOv-form-factor expansion card
Installing a compact-form-factor expansion card
Removing a storage interface card
Installing a storage interface card
Removing the control panel
Installing the control panel
Removing an optional expansion unit
Installing an optional expansion unit
Removing and replacing Tier 2 CRUs
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Thermal grease
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
HX5 Blade Server
PDF files
Product overview
Features and specifications
What your blade server offers
Reliability, availability, and serviceability features
IBM® Director
Major components
Working with a scalable blade complex
Safety and environmental notices
Notices and statements in this information
Safety
Guidelines for trained service technicians
Inspecting for unsafe conditions
Guidelines for servicing electrical equipment
kh9_r_safety_statements.html
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Japan Electronics and Information Technology Industries Association (JEITA) statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Power, controls, and indicators
Blade server controls and LEDs
Scalability indicators
Turning on the blade server
Turning off the blade server
System-board layouts
Connectors - BladeCenter HX5
System-board switches
Connectors - IBM MAX5
LEDs - BladeCenter HX5
LEDs - IBM MAX5
Input/output connectors and devices
Installing Options
Removing a blade server from a BladeCenter chassis
Removing the blade server cover
Disassembling a scalable blade complex
Removing the 2-node scalability card
Removing the IBM MAX5 1-node scalability card
Removing an IBM MAX5
Installing a DIMM - IBM MAX5
Removing a DIMM - IBM MAX5
Installing a SSD expansion card
Removing a SSD expansion card
Installing an SSD
Removing an SSD
Installing a DIMM - BladeCenter HX5
Removing a DIMM - BladeCenter HX5
Installing a hypervisor key
Removing a hypervisor key
Installing I/O expansion cards
Installing a CIOv expansion card
Installing a CFFh expansion card
Removing I/O expansion cards
Removing a CFFh expansion card
Removing a CIOv expansion card
Installing a PCI expansion blade
Removing a PCI expansion blade
Installing a microcessor and heat sink
Installing the 1-node speed burst card
Removing the 1-node speed burst card
Completing the installation
Assembling a scalable blade complex
Installing the scalability tray
Installing the 2-node scalabiity card
Installing an IBM MAX5
Installing the IBM MAX5 1-node scalabiity card
Installing the blade server cover
Installing the blade server in a BladeCenter chassis
Updating the blade server configuration
Configuring the blade server
Partitioning a scalable blade complex
Using the Setup utility
Using the PXE boot agent utility program
Using the Boot Menu program
Using the Advanced Settings Utility (ASU)
Updating the Universal Unique Identifier (UUID)
Updating the DMI/SMBIOS data
Using the LSI Logic Configuration Utility program
Updating firmware and device drivers
Updating firmware for blade servers operating as a single partition
Updating firmware for each blade server independently
Recovering from a UEFI update failure
In-band manual recover method
Out-of-band manual recover method
In_band_automated_recovery
Out_of_band_automated_recovery
Installing the operating system
Using the ServerGuide Setup and Installation CD
ServerGuide features
Typical operating-system installation
Installing the operating system without using ServerGuide
Using IBM ServerGuide Scripting Toolkit
Accessing the IMM
Potential conflicts with the LAN over USB interface
Resolving conflicts with the IMM LAN over USB interface
Configuring the LAN over USB interface manually
LAN over USB Windows Driver Installation
LAN over USB Linux Driver Installation
Troubleshooting
Start here
Diagnosing a problem
Undocumented problems
Diagnostics
Service bulletins
Checkout procedure
Diagnostic tools
Event logs
Viewing event logs through the Setup utility
Viewing event logs without restarting the blade server
POST error codes
IMM/AMM error codes
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs - BladeCenter HX5 blade server
Light path diagnostics LEDs - IBM MAX5
Dynamic system analysis diagnostic programs and messages
DSA editions
Running the diagnostic programs
Diagnostic text messages
Viewing the test results
Diagnostic messages
Microprocessor test
Memory test
IMM I2C test
Optical drive (CD or DVD) test
Ethernet controller test
Troubleshooting tables
General problems
Chassis problems
Hard disk drive problems
Intermittent problems
Keyboard or mouse problems
Memory problems
Monitor or video problems
Network connection problems
Optional-device problems
Power error messages
Power problems
Removable-media drive problems
ServerGuide problems
Service processor problems
Solving shared BladeCenter resource problems
Keyboard or mouse problems
Media tray problems
Network connection problems
Power problems
Video problems
Software problems
Universal Serial Bus (USB) port problems
Solving undetermined problems
Removing and replacing components
Parts listing
Parts listing - BladeCenter HX5 blade server
Parts listing - IBM MAX5
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Returning a device or component
Removing a blade server from a BladeCenter chassis
Installing the blade server in a BladeCenter chassis
Disassembling a scalable blade complex
Assembling a scalable blade complex
Removing and replacing Tier 1 CRUs
Removing the blade server cover
Installing the blade server cover
Removing the battery
Installing the battery
Removing and replacing Tier 2 CRUs
Removing the scalability tray
Installing the scalability tray
Removing the 1-node speed burst card
Installing the1-node speed burst card
Removing the 2-node scalability card
Installing the 2-node scalabiity card
Removing an IBM MAX5
Installing an IBM MAX5
Removing the IBM MAX5 1-node scalability card
Installing the IBM MAX5 1-node scalabiity card
Removing a PCI expansion blade
Installing a PCI expansion blade
Removing a SSD expansion card
Installing a SSD expansion card
Removing an SSD
Installing an SSD
Removing a DIMM - BladeCenter HX5
Installing a DIMM - BladeCenter HX5
Removing a DIMM - IBM MAX5
Installing a DIMM - IBM MAX5
Removing a hypervisor key
Installing a hypervisor key
Removing an I/O expansion card
Removing a CFFh expansion card
Removing a CIOv expansion card
Installing an I/O expansion card
Installing a CFFh expansion card
Installing a CIOv expansion card
Removing the control panel
Installing the control panel
Removing and replacing FRUs
Removing a microprocessor and heat sink
Installing a microprocessor and heat sink
Removing the system-board assembly
Installing the system-board assembly
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
JS12 Blade Server
JS20 Blade Server
JS21 Blade Server
JS22 Blade Server
JS23 and JS43 Blade Server
LS20 Blade Server
Installing
Troubleshooting
Warranty
LS21 Blade Server
Installing
Troubleshooting
Warranty
LS22 Blade Server
Installing
Troubleshooting
Warranty
LS41 Blade Server
Installing
Troubleshooting
Warranty
LS42 Blade Server
Installing
Troubleshooting
Warranty
PS700 Blade Server
PS701 and PS702 Blade Server
PS703 and PS704 Blade Server
QS21 Blade Server
Installing
Troubleshooting
QS22 Blade Server
Installing
Troubleshooting
Warranty
Special purpose blade devices
IBM WebSphere DataPower Integration Blade XI50B appliance
PDF files
Installing and Using
Getting help and technical assistance
Before you call
Using the documentation
Getting help and information from the World Wide Web
How to send DSA data to IBM
Creating a personalized support web page
Software service and support
Hardware service and support
IBM Taiwan product service
Notices
Trademarks
Important notes
Particulate contamination
Documentation format
Telecommunication regulatory statement
Electronic emission notices
Federal Communications Commission (FCC) statement
Industry Canada Class A emission compliance statement
Avis de conformité à la réglementation d'Industrie Canada
Australia and New Zealand Class A statement
European Union EMC Directive conformance statement
Germany Class A statement
Japan VCCI Class A statement
Korea Communications Commission (KCC) statement
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Safety
Safety statements
Introduction
Related documentation
The IBM Documentation CD
Hardware and software requirements
Using the Documentation Browser
Notices and statements in this document
Features and specifications
Major components of the blade appliance
Input/output connectors and devices
Power, controls, and indicators
Blade appliance controls and LEDs
Control panel controls and LEDs
Storage drive controls and LEDs
Expansion unit controls and LEDs
Turning on the blade appliance
Turning off the blade appliance
Installing and removing the blade appliance
Installation guidelines
System reliability guidelines
Handling static-sensitive devices
Installing the blade appliance
Installing the expansion unit
Installing the blade appliance in a BladeCenter unit
Updating the blade appliance configuration
Removing the blade appliance from the BladeCenter unit
Removing the expansion unit
Setting up the initial firmware configuration
Configuration requirements
Connection requirements
Information requirements
Password for administration account
Operational modes
Initializing the blade appliance
Verifying the configuration with the WebGUI
Completing the configuration
Defining the base configuration manually
Downloading the firmware image
Solving problems
Solving installation problems
Solving operational problems
IBM WebSphere DataPower Integration Blade XI50B unique information
Diagnostic tools overview
Error logs
Working with event logs during system startup
Viewing event logs without restarting the blade appliance
Parts listing,
HC10 Blade Workstation
Installing
Troubleshooting
Warranty
PN41 Deep Packet Inspection Blade
Getting Started
Installing
Troubleshooting
Warranty
Expansion units
BladeCenter Storage and I/O Expansion Blade
BladeCenter Memory and I/O Expansion Blade
BladeCenter PCI I/O Expansion Units
BladeCenter AMD Opteron LS41 Multiprocessor Expansion Unit
BladeCenter AMD LS42 Multiprocessor Expansion Unit
I/O modules
Ethernet switch modules
IBM BladeCenter 1/10 Gb Uplink Ethernet Switch Module
IBM BladeCenter Virtual Fabric 10Gb Switch Module
IBM BladeCenter 10 Gb Uplink Ethernet Switch Module
IBM BladeCenter Layer 2/3 Gigabit Ethernet Switch Module
IBM BladeCenter Layer 2-7 GbE Switch Module
Cisco Catalyst Switch Module 3012 for IBM BladeCenter
Cisco Catalyst Switch Module 3110X for IBM BladeCenter
Cisco Catalyst Switch Module 3110G for IBM BladeCenter
Cisco Systems Gigabit Ethernet Switch Module
Cisco Systems Fiber Intelligent Gigabit Ethernet Switch Module
IBM BladeCenter Server Connectivity Module
Fibre Channel switch modules
Brocade 10- and 20-port SAN Switch Modules for IBM BladeCenter
Cisco 4Gb 10 and 20 port Fibre Channel Switch Module for IBM BladeCenter
McDATA 10- and 20-port 4Gb Fibre Channel Switch Modules for IBM BladeCenter
QLogic 10- and 20-port 4 Gb Switch Modules for IBM BladeCenter
QLogic 10-port 4 Gb SAN Switch Module for IBM BladeCenter
QLogic 20-port 4 Gb SAN Switch Module for IBM BladeCenter
QLogic 20-port 8 Gb SAN Switch Module for IBM BladeCenter
InfiniBand switch modules
Cisco Systems 4X InfiniBand Switch Module for IBM BladeCenter
QLogic InfiniBand Ethernet Bridge Module for IBM BladeCenter
QLogic InfiniBand Fibre Channel Bridge Module for IBM BladeCenter
Pass-thru modules
IBM BladeCenter 10 Gb Ethernet Passthru Module
IBM BladeCenter Copper Pass-thru Module
IBM BladeCenter Optical Pass-thru Module
IBM 4X InfiniBand Pass-thru Module for IBM BladeCenter
IBM Intelligent Copper Pass-Thru Module for IBM BladeCenter
QLogic 4 Gb Intelligent Pass-thru Module for IBM BladeCenter
QLogic 8 Gb Intelligent pass-thru module
Storage I/O modules
IBM BladeCenter SAS Connectivity Module
IBM BladeCenter SAS RAID Controller Module
Expansion cards
Cisco 4X InfiniBand DDR CFF Expansion Card (CFFh)
Cisco InfiniBand HCA Expansion Card
Cisco Topspin InfiniBand HCA Expansion Card
Emulex 4 Gb Fibre Channel Expansion Card (CFFv)
Emulex 4 Gb SFF Fibre Channel Expansion Card
IBM 2/4 Port Ethernet Expansion Card (CFFh)
IBM 4X InfiniBand DDR Expansion Card (CFFh)
IBM BladeCenter Concurrent KVM Feature Card
IBM Ethernet Expansion Card (CIOv)
IBM BladeCenter Fibre Channel Expansion Card and JS20 Fibre Channel Expansion Card
IBM Gigabit Ethernet Expansion Card (CIOv)
IBM BladeCenter SAS Expansion Card (CFFv)
IBM BladeCenter SAS Connectivity Card (CIOv)
IBM BladeCenter SFF Fibre Channel Expansion Card
IBM BladeCenter SFF Gigabit Ethernet Expansion Card
IBM System i5 Integrated xSeries PCI-x iSCSI HBA (copper)
IBM System i5 Integrated xSeries PCI-x iSCSI HBA (fiber)
Intel Gigabit Ethernet Expansion Card
Intel 10Gb 2-port Ethernet Expansion Card (CFFh)
Myrinet Cluster Expansion Card
NetXen 10 Gb 2-Port Ethernet Expansion Card
QLogic 4 Gb Fibre Channel Expansion Card (CIOv)
QLogic 4 Gb SFF Fibre Channel Expansion Card
QLogic 4 Gb Standard Fibre Channel Expansion Card
QLogic 8 Gb Fibre Channel Expansion Card (CIOv)
QLogic Ethernet and 8 Gb Fibre Channel Expansion Card (CFFh)
QLogic iSCSI Expansion Card
Voltaire 4X InfiniBand DDR (CFFh) Expansion Card